Veritas Logo

Table of Contents (hide)

Top of Document

Updated: 2019-09-02 11:19 AM America/New_York

Veritas Logo

Backup Exec 20 - 20.x Hardware and Cloud Storage Compatibility List (HCL)

Copyright © 2019 Veritas Technologies LLC. All rights reserved. Veritas, the Veritas Logo, and Backup Exec are trademarks or registered trademarks of Veritas Technologies LLC or its affiliates in the U.S. and other countries. Other names may be trademarks of their respective owners.

Created on September 02, 2019

Introduction

This Hardware Compatibility List (HCL) document contains information for all editions of Backup Exec 20. All hardware must be present on this HCL for support, unless a section clearly states that the devices listed are not the only devices supported (such as the Disk Target section). If your tape drive, tape library, or virtual tape library is not properly detected, please update your system using the latest Update (previously called a Feature Pack) before calling Support. Updating the drivers frequently resolves device related issues. This update can be found on our support site. https://www.veritas.com/support/en_US/15047.html Please see these links for information about how and where to obtain updates https://www.veritas.com/support/en_US/article.000036756 and https://www.veritas.com/support/en_US/article.100041552

Backup Exec support policy is that all of the vendors involved (both hardware and software) must support all the pieces involved. For example, the Host Bus Adapter must be supported by the hardware vendor and the operating system vendor in order for Veritas to provide support. Always consult the hardware manufacturer's support list and the operating system vendor's support list when troubleshooting or planning a data protection installation. All entries were believed to be fully supported by all parties involved when they were added to this Veritas list, but if a vendor drops their support after this list was published, Veritas support will be on a reasonable-effort basis.

Hardware is selected and prioritized for certification based on market research and input from the field, including customer feedback. If a customer would like to have their hardware considered for inclusion on this HCL, simply submit the request via an email mailto:Backup_Exec_HCL@veritas.com . Requests will be reviewed by the appropriate Veritas Product Management team members for possible certification, with final decisions based on the overall fit with the product, target market, and frequency of request.

Some notes about drivers: Veritas Kernel-mode Tape drivers and tapeinst.exe are no longer installed if Backup Exec 20 is installed on Windows Server 2012 or later. There are no devices on this Backup Exec 20 Hardware Compatibility List (HCL) that require Veritas Kernel-mode drivers. USB tape devices still require a Microsoft or vendor Kernel-mode driver, in addition to the Veritas User-mode driver. Users of very old, unsupported, tape devices should investigate and test before using Windows Server 2012 or later to determine the functionality as kernel-mode drivers may be required. All supported tape devices are now accessed by Veritas User-mode drivers. Most tape devices have been accessed by User-mode drivers for multiple previous versions of Backup Exec.

User-mode drivers are not visible in the Windows Device Manager. When no Kernel-mode drivers are installed, the Windows Device Manager may show the tape drive with a yellow exclamation mark. This is acceptable and does NOT prevent the device from being used with Backup Exec and the User-mode drivers. Kernel-mode drivers from Microsoft or the tape hardware vendor are generally acceptable to be installed. Backup Exec will continue to access the tape devices via User-mode drivers.

Tapeinst.exe is the program that installs Veritas Kernel-mode tape class drivers. When using Windows Server 2008 R2 or earlier, tapeinst.exe can be invoked manually or via the "Install Tape Device Drivers" wizard (under the "Configure Storage" menu). When using Windows Server 2012 or later, the ability to run the "Install Tape Device Drivers" wizard (under the Configure Storage menu) is no longer present and is not needed.

Some notes about tape drive block sizes: Please be sure to consult this technote when using tape drive block sizes above the 64KB default size. http://www.veritas.com/docs/000035564

Alternative Configurations: Our Licensed Software is designed to interoperate with many types of systems, applications, and hardware. Sometimes a customer may choose to use our Licensed Software in an "Alternative Configuration", namely, an environment that has not been validated, approved or verified to operate with our Licensed Software or which does not support such Licensed Software or only supports limited functionality. In most cases, we do not support Alternative Configurations, and we have no obligation to provide Support Services to Licensed Software in an Alternative Configuration. Veritas makes no warranty with respect to use of Licensed Software in an Alternative Configuration and any such use is at your own risk. A "Supported Configuration" might be converted into an Alternative Configuration where a vendor modifies one of its components that is part of the original Supported Configuration. As a consequence, your Licensed Software would then be operating in an Alternative Configuration. If you experience a problem with the Licensed Software in an Alternative Configuration or if your issue deals with script that was not developed by Veritas or an authorized consulting partner, then we may ask you to reproduce the problem in a Supported Configuration environment. Please note we have no obligation to attempt to resolve problems that cannot be replicated in a Supported Configuration. However, if the problem can be replicated in a Supported Configuration, we will investigate the problem in that Supported Configuration and attempt to resolve it. If the problem cannot be replicated in a Supported Configuration, then we may elect not to work on that problem.

Configuring a tape device with a virtual machine is considered an "Alternative Configuration". For more details on the configuration of virtual machines with tape devices, see the following related articles, http://www.veritas.com/docs/000007409 , http://www.veritas.com/docs/000010619 , and http://www.veritas.com/docs/000038480 .

Backup Exec Documentation

ItemLocation
Backup Exec 20.5 Administrator's Guidehttps://www.veritas.com/support/en_US/doc/59226269-137906722-0
Backup Exec 20.4 Administrator's Guidehttps://www.veritas.com/support/en_US/doc/59226269-135381838-0
Backup Exec 20.3 Administrator's Guidehttps://www.veritas.com/support/en_US/doc/59226269-133519926-0
Backup Exec 20.2 Administrator's Guidehttps://www.veritas.com/support/en_US/doc/59226269-132544165-0
Backup Exec 20.0 Administrator's Guidehttps://www.veritas.com/support/en_US/doc/59226269-99535599-0
Backup Exec 20.5 Readmehttps://www.veritas.com/support/en_US/doc/59226813-137906761-0
Backup Exec 20.4 Readmehttps://www.veritas.com/support/en_US/doc/59226813-135381841-0
Backup Exec 20.3 Readmehttps://www.veritas.com/support/en_US/doc/59226813-133519999-0
Backup Exec 20.2 Readmehttps://www.veritas.com/support/en_US/doc/59226813-132544169-0
Backup Exec 20.1 Readmehttps://www.veritas.com/support/en_US/doc/59226813-131650528-0
Backup Exec 20.0 Readmehttps://www.veritas.com/support/en_US/doc/59226813-126999530-0
Backup Exec 20.5 Best Practiceshttps://www.veritas.com/support/en_US/doc/72686287-137906734-0
Backup Exec 20.4 Best Practiceshttps://www.veritas.com/support/en_US/doc/72686287-136078496-0
Backup Exec 20.3 Best Practiceshttps://www.veritas.com/support/en_US/doc/72686287-133836755-0
Backup Exec 20.2 Best Practiceshttps://www.veritas.com/support/en_US/doc/72686287-133408718-0
Backup Exec 20.5 What's Newhttps://www.veritas.com/support/en_US/doc/125172030-139024698-1
Backup Exec 20.4 What's Newhttps://www.veritas.com/support/en_US/doc/125172030-137507153-1
Backup Exec 20.3 What's Newhttps://www.veritas.com/support/en_US/doc/125172030-135182712-1
Backup Exec 20.2 What's Newhttps://www.veritas.com/support/en_US/doc/125172030-133605728-1
Backup Exec 20.3 Licensing Guidehttps://www.veritas.com/support/en_US/doc/BE203_Licensing_Guide
Backup Exec 20.2 Licensing Guidehttps://www.veritas.com/support/en_US/doc/BE202_Licensing_Guide
Backup Exec 20 Command Line Interface Help Downloadhttps://www.veritas.com/support/en_US/article.100041183
Backup Exec 20.5 Tuning and Performance Guidehttps://www.veritas.com/support/en_US/doc/40056030-139024710-1
Backup Exec 20.4 Tuning and Performance Guidehttps://www.veritas.com/support/en_US/doc/40056030-137507165-1
Backup Exec 20.3 Tuning and Performance Guidehttps://www.veritas.com/support/en_US/doc/40056030-135180484-1
Backup Exec 20.2 Tuning and Performance Guidehttps://www.veritas.com/support/en_US/doc/40056030-133620529-1
Backup Exec 20.0 Tuning and Performance Guidehttps://www.veritas.com/support/en_US/doc/40056030-98804569-1
Backup Exec 20 - 20.x Software Compatibility List (SCL)https://www.veritas.com/support/en_US/doc/BE_20_SCL

Introduction | Backup Exec Documentation | Newly-Supported Devices | Select hardware by BE option or agent | Cloud Storage | Disk Targets | Virtual Tape Libraries with Drives | Tape Drives | Tape Libraries with Drives | NDMP Platforms | NAS Sources | SAN Infrastructure Components | Retiring Soon | Support End-of-Life

Newly-Supported Devices

The following new devices have been added to this HCL since the last time it was created. The creation date is listed on the first page of this document. See the device in its respective section, via bookmarks, for more details.

Veritas Update (previously LiveUpdate) will obtain the latest updates for your BE version.

Your device may require that you download and install an Update (previously called a Feature Pack), but it is RECOMMENDED that the latest patches are always used. If a new Update is utilized, it is required that Simplified Disaster Recovery (SDR) users regenerate the SDR boot media.

New Backup-to-cloud | S3 Cloud connector:

1. Google Cloud Regional - Australia-Southeast1, Asia-East2, Asia-South1, Asia-Northeast2, EU-North1, EU-West4, EU-West6, NorthAmerica-Northeast1, SouthAmerica-East1, US-West2 locations

2. Amazon Simple Storage Service (S3) - Hong Kong Region

3. Amazon Simple Storage Service (S3) - Intelligent Tiering

4. Amazon Simple Storage Service (S3) - One Zone Infrequent Access

5. Amazon Simple Storage Service (S3) - Glacier

6. Amazon Simple Storage Service (S3) - Glacier Deep Archive

New tape libraries:

1. NEC T280 with LTO8 - SAS

2. NEC T280 with LTO7 - SAS

3. NEC T280 with LTO8 - FC

4. NEC T280 with LTO7 - FC

New NDMP Option components:

1. NetApp Data ONTAP 9.6

For details about Backup Exec 20 Update 5 (aka 20.5), please see https://www.veritas.com/support/en_US/article.100043577 Released Sept 02, 2019

For details about Backup Exec 20 Update 4 (aka 20.4), please see https://www.veritas.com/support/en_US/article.100045539 Released May 06, 2019

For details about Backup Exec 20 Update 3 (aka 20.3), please see https://www.veritas.com/support/en_US/article.100044290 Released Oct 23, 2019

For details about Backup Exec 20 Update 2 (aka 20.2), please see https://www.veritas.com/support/en_US/article.100043740 Released August 13, 2018

For details about Backup Exec 20 Update 1 (aka 20.1), please see https://www.veritas.com/support/en_US/article.100042544 Released April 02, 2018

Backup Exec 20.0 was released November 06, 2017

Select hardware by BE option or agent

The listed options and agents have hardware requirements. They are included here for the purpose of helping choose the appropriate hardware for the selected agent/option.

Advanced Disk-based Backup Option

The Advanced Disk-based Backup Option (ADBO, included with the Enterprise Server Option), as it relates to hardware devices in this HCL, can be seen in the VSS Providers for Offhost backup section.

Deduplication Option

The Deduplication Option support information is included with the Disk Targets sections. There are two basic options to choose from:
1. Backup Exec Deduplication Option Storage. To find tested devices, search by storage device vendor in the Disk Targets | Disk Storage section, then model, then look for a check [] in the "dedup" column for tested disk devices.
2. Deduplication Appliance - sometimes referred to as OpenStorage devices from our hardware/software partners. See the OST-Appliance section.

Simplified Disaster Recovery Option

The Simplified Disaster Recovery (SDR) Option is supported on tape libraries, tape drives, virtual tape libraries, and disk devices (present at system start time) unless otherwise mentioned in a footnote, or section header paragraph.

For compatibility information on physical tape libraries with SDR, please refer to the Tape Libraries with Drives Section of this document.

For compatibility information on virtual tape libraries (VTLs) with SDR, please refer to the Virtual Tape Libraries with Drives Section of this document.

For compatibility information on tape drives with SDR, please refer to the Tape Drives Section of this document.

NDMP Option

The storage devices supported by the NDMP option are included with the Tape Library / Virtual Tape Library sections. Please refer to the NDMP-specific notes in the "NDMP Platforms" section. These notes can be found as footnotes, per NDMP vendor / device combination. These notes apply to the "Virtual Tape Libraries with Drives" and "Tape Libraries with Drives Section" sections. Search by storage device vendor, then model, then look for a check [] in the NDMP column for support. Please note that the presence of a check means that Veritas will support the storage device and NDMP combination IF and ONLY IF the NDMP vendor also supports the library / drive combination. Please refer to the NDMP vendors' documentation for storage device support.

For compatibility information on NDMP platforms supported, please refer to the NDMP Platforms Section of this document.

For compatibility information on physical tape libraries with NDMP, please refer to the Tape Libraries with Drives Section of this document.

For compatibility information on virtual tape libraries (VTLs) with NDMP, please refer to the Virtual Tape Libraries with Drives Section of this document.

Remote Media Agent for Linux

The Remote Media Agent for Linux (RMAL) support information is included with the Tape Library / Virtual Tape Library / Tape Drives sections. Search by storage device vendor, then model, then look for a check [] in the RMAL column for support.

For compatibility information on physical tape libraries with RMAL, please refer to the Tape Libraries with Drives Section of this document.

For compatibility information on virtual tape libraries (VTLs) with RMAL, please refer to the Virtual Tape Libraries with Drives Section of this document.

For compatibility information on tape drives with RMAL, please refer to the Tape Drives Section of this document.

Enterprise Server Option for use with SAN shared storage

The SAN Shared Storage Option is now available as part of the Enterprise Server Option in Backup Exec 2012, Backup Exec 2014, Backup Exec 15, Backup Exec 16 & Backup Exec 20. All references to SSO on the HCL are now replaced with ESO due to the change. If you used the SAN Shared Storage Option in a previous version of Backup Exec, the SAN primary server will be upgraded to a Central Administration Server. SAN secondary servers will be upgraded to Managed Backup Exec Servers and will have the Managed Backup Exec Server option installed and the Unrestricted access to catalogs and backup sets for restore option selected.

The Enterprise Server Option (ESO) hardware support information is included with the Tape Library / Virtual Tape Library sections. Search by storage device vendor, then model, then look for a check [] in the ESO column for support.

For compatibility information on physical tape libraries with ESO, please refer to the Tape Libraries with Drives Section of this document.

For compatibility information on virtual tape libraries (VTLs) with ESO, please refer to the Virtual Tape Libraries with Drives Section of this document.

For compatibility information on storage area network (SAN) components with ESO, inlcuding fibre-channel and iSCSI components, please refer to the SAN Infrastructure components Section of this document.

Library Expansion Option

The Library Expansion Option (LEO) supported hardware configurations, including tape library and tape drive combinations, can be seen in the Tape Libraries with Drives section.

Virtual Tape Library Unlimited Drive Option

The Virtual Tape Library Unlimited Drive Option (VUDO) supported hardware configurations, including virtual tape library and virtual tape drive combinations, can be seen in the Virtual Tape Libraries with Drives section.

Often, a single VTL can be configured with a variable number of tape drives and tape libraries. VUDO allows for the variance in drives per physical VTL, not logical VTL. In other words, creating more than one logical VTL will require the need for multiple VUDO licenses.

Cloud Storage

Please see the "Best Practices for Using the Veritas Backup Exec Cloud Connector" at http://www.veritas.com/docs/000108140

Backup Exec supports Cloud-based storage providers using a variety of technology methods, described below.

1) Azure Storage - This method uses the Backup Exec "Azure Cloud Connector" (a plugin included with Backup Exec). This target appears in Backup Exec with a Storage Type of "Cloud Storage".

2) S3 Storage - This method uses the Backup Exec "S3 Cloud Connector" (a plugin included with Backup Exec). This target appears in Backup Exec with a Storage Type of "Cloud Storage".

3) OST - This method uses a third-party Open Storage Technology plugin. This methods requires a Deduplication license in Backup Exec. This target appears in BE with a Storage Type of "OpenStorage".

4) Disk Targets - This method uses third-party hardware or software to make the cloud appear as a "regular" disk volume to Windows and Backup Exec. This target appears in Backup Exec with a Storage Type of "Disk storage".

5) VTL - This method uses third-party software to present the Cloud as if it was a VTL (Virtual Tape Library) to Windows and Backup Exec. A BE VUDO license is suggested. This target appears in Backup Exec with a Storage Type of "Robotic Library".

Listed below are the supported and tested Cloud Storage solutions. Other Cloud Storage solutions may work, but it would be treated as an "Alternative Configuration". See this article for more information http://www.veritas.com/docs/000126210 Cloud solutions are selected and prioritized for certification based on market research and input from the field, including customer feedback. If a customer would like to have their cloud and/or hardware considered for inclusion on this HCL, simply submit the request via an email mailto:Backup_Exec_HCL@veritas.com . Requests will be reviewed by the appropriate Veritas Product Management team members for possible certification, with final decisions based on the overall fit with the product, target market, and frequency of request.

Go to Top of "Cloud Storage"

Cloud Providers and Technology Methods

Cloud ProviderTechnology method
Alibaba Cloud Object Storage Service (OSS)Backup Exec S3 Cloud connector
Amazon Simple Storage Service (S3) StandardBackup Exec S3 Cloud connector
Amazon Simple Storage Service (S3) StandardRiverbed Appliance
Amazon Simple Storage Service (S3) StandardNetApp AltaVault
Amazon Simple Storage Service (S3) Standard and GlacierDatish Systems OpenDedupe OST
Amazon Simple Storage Service (S3) Standard - Infrequent AccessBackup Exec S3 Cloud connector
Amazon Simple Storage Service (S3) One Zone Infrequent AccessBackup Exec S3 Cloud connector
Amazon Simple Storage Service (S3) Intelligent TieringBackup Exec S3 Cloud connector
Amazon Simple Storage Service (S3) GlacierBackup Exec S3 Cloud connector
Amazon Simple Storage Service (S3) Glacier Deep ArchiveBackup Exec S3 Cloud connector
Amazon Simple Storage Service and GlacierAmazon AWS VTL
Amazon Web ServicesAmazon Gateway-Cached Volume
Chunghwa Telecom hicloud S3Backup Exec S3-Compatible Cloud connector
Cloudian HyperStore Object StorageBackup Exec S3 Cloud connector
Dell EMC Elastic Cloud Storage (ECS)Backup Exec S3 Cloud connector
Google Cloud Multi-RegionalBackup Exec S3 Cloud connector
Google Cloud RegionalBackup Exec S3 Cloud connector
Google Cloud NearlineBackup Exec S3 Cloud connector
Google Cloud ColdlineBackup Exec S3 Cloud connector
Google Cloud Durable Reduced Availability (DRA)Backup Exec S3 Cloud connector
Google Cloud Multi-RegionalDatish Systems OpenDedupe OST
Google Cloud RegionalDatish Systems OpenDedupe OST
IBM Cloud Object StorageBackup Exec S3-Compatible Cloud connector
Infoniqa SWISS3CLOUDBackup Exec S3-Compatible Cloud connector
Microsoft AzureBackup Exec Azure Cloud connector
Microsoft AzureNetApp AltaVault
Microsoft AzureMicrosoft StorSimple
Microsoft AzureRiverbed Appliance
Microsoft AzureDatish Systems OpenDedupe OST
Microsoft Azure ArchiveDatish Systems OpenDedupe OST
Private S3 Cloud StorageBackup Exec S3 Cloud connector
Quantum Q-Cloud Protect for AWSQuantum-provided OST plugin
RedHat Ceph StorageBackup Exec S3 Cloud connector
Scality RING StorageBackup Exec S3-Compatible Cloud connector
Telefonica Open CloudBackup Exec S3-Compatible Cloud connector
Veritas Access StorageBackup Exec S3-Compatible Cloud connector

Azure Cloud

You can use the Azure Cloud Connector to back up data to Microsoft Azure cloud storage.

Go to Top of "Azure Cloud"

Microsoft

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inSupported Regions
Azure [1]Backup Exec 16All Locales
  • f3-1
Azure China [1]Backup Exec 16All Locales
  • f3-1
Azure Germany [1]Backup Exec 16 FP2All Locales
  • f3-1
Azure Government [1]Backup Exec 16 FP2All US Gov Locales
  • f3-1
  1. Hot-tier and cool-tier are supported.

S3 Storage

You can use the S3 Cloud Connector to back up data to a supported S3-compatible cloud storage.

The below section lists the S3-compatible cloud storage solutions that are currently supported by Backup Exec and the BE 20 Update or BE 16 Feature Pack (FP) required for support.

Go to Top of "S3 Storage"

Alibaba Cloud

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inLocales / Regions
Object Storage Service (OSS) [1]Backup Exec 20 Update 3 (aka 20.3)All Locales
  • f4-1
  1. To configure this cloud storage for use with Backup Exec, see the following article https://vox.veritas.com/t5/Backup-Exec/Backup-Exec-BE-workload-protection-with-Alibaba-Object-Storage/ba-p/858791
Go to Top of "S3 Storage"

Amazon

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inSupported Regions
Simple Storage Service (S3) Standard [1][2][3][4]Backup Exec 15 FP2US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai)
  • f5-1
  • f5-2
  • f5-3
  • f5-4
Simple Storage Service (S3) Standard [1][2][3][4]Backup Exec 16 FP1US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing) [5]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-5
Simple Storage Service (S3) Standard [1][2][3][4]Backup Exec 20 Update 3 (aka 20.3)US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing), China (Ningxia), Europe (Paris) [6]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-6
Simple Storage Service (S3) Standard [1][2][3][4]Backup Exec 20 Update 4 (aka 20.4)US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing), China (Ningxia), Europe (Paris), Sweden (Stockholm) [7]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-7
Simple Storage Service (S3) Standard [1][2][3][4]Backup Exec 20 Update 5 (aka 20.5)US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing), China (Ningxia), Europe (Paris), Sweden (Stockholm), Hong Kong [8]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-8
Simple Storage Service (S3) Standard [1][2][3][4]Backup Exec 16 FP2US West1 (Gov Non-FIPS)
  • f5-1
  • f5-2
  • f5-3
  • f5-4
Simple Storage Service (S3) Standard [1][2][3][4]Backup Exec 20 Update 1 (aka 20.1)US West1 (Gov FIPS 140-2)
  • f5-1
  • f5-2
  • f5-3
  • f5-4
Simple Storage Service (S3) Standard - Infrequent Access [1][2][3][4]Backup Exec 16 FP1US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing) [9]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-9
Simple Storage Service (S3) Standard - Infrequent Access [1][2][3][4]Backup Exec 20 Update 3 (aka 20.3)US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing) China (Ningxia), Europe (Paris) [6]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-6
Simple Storage Service (S3) Standard - Infrequent Access [1][2][3][4]Backup Exec 20 Update 4 (aka 20.4)US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing), China (Ningxia), Europe (Paris), Sweden (Stockholm) [10]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-10
Simple Storage Service (S3) Standard - Infrequent Access [1][2][3][4]Backup Exec 20 Update 5 (aka 20.5)US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing), China (Ningxia), Europe (Paris), Sweden (Stockholm), Hong Kong [11]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-11
Simple Storage Service (S3) Intelligent Tiering [1][2][3][4]Backup Exec 20 Update 5 (aka 20.5)US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing), China (Ningxia), Europe (Paris), Sweden (Stockholm), Hong Kong [12]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-12
Simple Storage Service (S3) One Zone Infrequent Access [1][2][3][4]Backup Exec 20 Update 5 (aka 20.5)US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing), China (Ningxia), Europe (Paris), Sweden (Stockholm), Hong Kong [13]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-13
Simple Storage Service (S3) Glacier [1][2][3][4]Backup Exec 20 Update 5 (aka 20.5)US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing), China (Ningxia), Europe (Paris), Sweden (Stockholm), Hong Kong [14]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-14
Simple Storage Service (S3) Glacier Deep Archive [1][2][3][4]Backup Exec 20 Update 5 (aka 20.5)US East (N. Virginia), US West (Oregon), US West (N. California), Europe (Ireland), Asia Pacific (Singapore), Asia Pacific (Tokyo), Asia Pacific (Sydney), South America (Sao Paulo), Asia Pacific (Seoul), Europe (Frankfurt), Asia Pacific (Mumbai), US East (Ohio), Canada (Central), Europe (London), China (Beijing), China (Ningxia), Europe (Paris), Sweden (Stockholm), Hong Kong [15]
  • f5-1
  • f5-2
  • f5-3
  • f5-4
  • f5-15
  1. To configure this cloud storage for use with Backup Exec, see the following article http://www.veritas.com/docs/000081253
  2. To get started with AWS S3, go to the following link http://aws.amazon.com/s3
  3. Amazon S3 Standard is supported. Amazon S3-IA is supported with BE 16 FP1 (or greater). Amazon Glacier is supported with BE 20.5 (or greater)
  4. Transfer Acceleration for AWS S3 is not currently supported in BE
  5. Support for the US East (Ohio), Canada (Central), Europe (London) or China (Beijing) regions requires BE 16 FP1 (or higher). See http://www.veritas.com/docs/000116034
  6. Support for the China (Ningxia) or Europe (Paris) region requires BE 20.3 (or higher). See http://www.veritas.com/docs/100041943
  7. Support for the Sweden (Stockholm) region requires BE 20.4 (or higher). See http://www.veritas.com/docs/100043560
  8. Support for the Hong Kong region requires BE 20.5 (or higher). See https://www.veritas.com/support/en_US/article.100043577
  9. Support for IA requires BE 16 FP1 (or higher). See http://www.veritas.com/docs/000116034
  10. Support for the Sweden (Stockholm) region requires BE 20.4 (or higher). See http://www.veritas.com/docs/100043560
  11. Support for the Sweden (Stockholm) region requires BE 20.5 (or higher). See https://www.veritas.com/support/en_US/article.100043577
  12. Support for Intelligent Tiering requires BE 20.5 (or higher). See https://www.veritas.com/support/en_US/article.100043577
  13. Support for One Zone Infrequent Access requires BE 20.5 (or higher). See https://www.veritas.com/support/en_US/article.100043577
  14. Support for Glacier requires BE 20.5 (or higher). See https://www.veritas.com/support/en_US/article.100043577
  15. Support for Glacier Deep Archive requires BE 20.5 (or higher). See https://www.veritas.com/support/en_US/article.100043577
Go to Top of "S3 Storage"

Chunghwa Telecom

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inLocales / Regions
hicloud S3 [1]Backup Exec 20 Update 1 (aka 20.1)All Locales
  • f6-1
  1. The Provider Name "Compatible-with-S3" will be required for creating Cloud Instance using bemcli. For steps on using bemcli to create a new cloud instance, please see http://www.veritas.com/docs/000126210
Go to Top of "S3 Storage"

Cloudian

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inLocales / Regions
Cloudian HyperStore Object Storage [1]Backup Exec 15 FP5On-Premises
  • f7-1
  1. The Provider Name "Cloudian" will be required for creating Cloud Instance using bemcli. For steps on using bemcli to create a new cloud instance, please see http://www.veritas.com/docs/000114986
Go to Top of "S3 Storage"

Dell EMC

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inLocales / Regions
Dell EMC Elastic Cloud Storage (ECS) [1]Backup Exec 16 FP1On-Premises
  • f8-1
  1. The Provider Name "emc-ecs" will be required for creating Cloud Instance using bemcli. For steps on using bemcli to create a new cloud instance, please see http://www.veritas.com/docs/000114986
Go to Top of "S3 Storage"

Google

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inSupported Locations
Google Cloud Multi-Regional [1][2]Backup Exec 15 FP2Asia, European Union, United States
  • f9-1
  • f9-2
Google Cloud Regional [1]Backup Exec 16 FP2US-Central1, US-East1, US-West1, US-East4, US-West1, US-West2, Asia-East1, Asia-Northeast1, Asia-Southeast1, Australia-Southeast1
  • f9-1
Google Cloud Regional [1]Backup Exec 20.5US-Central1, US-East1, US-West1, US-East4, US-West1, US-West2, Asia-East1, Asia-Northeast1, Asia-Southeast1, Australia-Southeast1, Asia-East2, Asia-South1, Asia-Northeast2, EU-North1, EU-West4, EU-West6, NorthAmerica-Northeast1, SouthAmerica-East1, US-West2 [3]
  • f9-1
  • f9-3
Google Cloud Nearline [1][4]Backup Exec 16Asia, European Union, United States
  • f9-1
  • f9-4
Google Cloud Coldline [1][4]Backup Exec 16Asia, European Union, United States
  • f9-1
  • f9-4
Google Cloud Durable Reduced Availability (DRA) [1][4]Backup Exec 15 FP2Asia, European Union, United States
  • f9-1
  • f9-4
  1. To configure this cloud storage for use with Backup Exec, see the following article http://www.veritas.com/docs/000097974
  2. Regional locations are NOT supported (unless using FP2). For example, US-East1, US-Central1, Europe-West1 and Asia-East1 are NOT supported.
  3. Support for the Asia-East2, Asia-South1, Asia-Northeast2, EU-North1, EU-West4, EU-West6, NorthAmerica-Northeast1, SouthAmerica-East1, US-West2 location requires BE 20.5 (or higher). See https://www.veritas.com/support/en_US/article.100043577
  4. Regional locations are NOT supported. For example, US-East1, US-Central1, Europe-West1 and Asia-East1 are NOT supported.
Go to Top of "S3 Storage"

IBM

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inLocales / Regions
Cloud Object Storage [1]Backup Exec 20 Update 1 (aka 20.1)All Locales
  • f10-1
  1. The Provider Name "Compatible-with-S3" will be required for creating Cloud Instance using bemcli. For steps on using bemcli to create a new cloud instance, please see http://www.veritas.com/docs/000126210
Go to Top of "S3 Storage"

Infoniqa

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inLocales / Regions
SWISS3CLOUD [1]Backup Exec 20All Locales
  • f11-1
  1. The Provider Name "Compatible-with-S3" will be required for creating Cloud Instance using bemcli. For steps on using bemcli to create a new cloud instance, please see http://www.veritas.com/docs/000126210
Go to Top of "S3 Storage"

RedHat

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inLocales / Regions
RedHat Ceph Storage [1]Backup Exec 16 FP1On-Premises
  • f12-1
  1. The Provider Name "rhceph" will be required for creating Cloud Instance using bemcli. For steps on using bemcli to create a new cloud instance, please see http://www.veritas.com/docs/000114986
Go to Top of "S3 Storage"

Scality

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inLocales / Regions
Scality RING Storage [1]Backup Exec 16 FP2On-Premises
  • f13-1
  1. The Provider Name "Compatible-with-S3" will be required for creating Cloud Instance using bemcli. For steps on using bemcli to create a new cloud instance, please see http://www.veritas.com/docs/000126210
Go to Top of "S3 Storage"

Telefonica

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inLocales / Regions
Telefonica Open Cloud [1]Backup Exec 20All Locales
  • f14-1
  1. The Provider Name "Compatible-with-S3" will be required for creating Cloud Instance using bemcli. For steps on using bemcli to create a new cloud instance, please see http://www.veritas.com/docs/000126210
Go to Top of "S3 Storage"

Veritas

Cloud Storage SolutionFirst Backup Exec Version Containing Plug-inLocales / Regions
Veritas Access Storage [1][2]Backup Exec 20On-Premises
  • f15-1
  • f15-2
  1. The Provider Name "vtas-access" will be required for creating Cloud Instance using bemcli. For steps on using bemcli to create a new cloud instance, please see http://www.veritas.com/docs/000126210
  2. All Veritas Access versions and form-factors are supported, including Veritas built appliances and other appliances.

OST

Backup Exec OpenStorage (OST) Cloud Storage plug-ins enable Veritas data protection applications to access Cloud Storage Solutions. Either the storage vendor or Veritas provides a software plug-in, which is installed on each Backup Exec server that is connected to the cloud solution. If you do not see OST support for your desired Cloud Storage Solution provider / Backup Exec Server OS platform, please contact that Storage Server appliance vendor to request OST support for that platform. Please see the Backup Exec System Administrator's Guide for more information on how to use OST.

Go to Top of "OST"

Quantum

Cloud Storage SolutionCloud API VersionQuantum Plug-in versionWindows Server 2008Windows Server 2012Windows Server 2016
Q-Cloud Protect for AWS [1][2][3]DXi Software 3.1.13.1
  • f16-1
  • f16-2
  • f16-3
  1. For information on how to setup Q-Cloud Protect with Backup Exec, goto http://www.quantum.com/serviceandsupport/softwareanddocumentationdownloads/index.aspx select the appropriate DXi product, select the "Documentation" tab, in the best practices section select "DXi-Series and Best Practices Guide for Backup Exec from Symantec". Once you enter the appropriate serial number, search for Appendix A.
  2. DXi server model DXi8500 (3TB) or DXi6802 is required to support Data-at-Rest encryption.
  3. See the Quantum OST appliance section also
Go to Top of "OST"

Datish Systems OpenDedupe

Cloud Storage SolutionFilesystem VersionDatish Plug-in versionWindows Server 2012Windows Server 2016Supported Regions
OpenDedupe for Amazon AWS (S3 Standard), Azure, Google (Regional, Multi-Regional) [1][2][3][4][5][6]Datish Systems SDFS 3.4.10.12.1.3.0US only
  • f17-1
  • f17-2
  • f17-3
  • f17-4
  • f17-5
  • f17-6
OpenDedupe for Amazon AWS (S3 Standard, Glacier), Azure, Azure Archive, Google (Regional, Multi-Regional) [1][2][3][4][5][6][7][8]Datish Systems SDFS 3.6.0.132.2.7.0All Regions
  • f17-1
  • f17-2
  • f17-3
  • f17-4
  • f17-5
  • f17-6
  • f17-7
  • f17-8
  1. For more information go to http://www.veritas.com/docs/000127295
  2. For more information go to http://opendedup.org
  3. Installation demonstration videos are at https://youtu.be/VAa-K8WIXVo and https://youtu.be/Pf_xCj2FynI
  4. Note: OpenDedupe devices must NOT be shared between BE server nodes, even in an MMS/CAS environment. Do not use the same cloud bucket for two different BE servers. OpenDedupe does not support device sharing at this time. Although BE may allow you to share the device, you must not share it. Corruption of the dedupe data is a likely result.
  5. The OpenDedupe OST Plugin is not supported on a Backup Exec Remote Agent. The Opendedupe OST plugin must be used on a Backup Exec Server.
  6. See the Datish Systems OST section also
  7. Backup Exec 20 Update 1 (aka 20.1) (or higher) is required. https://www.veritas.com/support/en_US/article.100042544
  8. An OpenDedupe upgrade demonstration video is at https://www.youtube.com/watch?v=YJFXLjswXbA or https://vox.veritas.com/t5/Backup-Exec/Video-How-to-Upgrade-OpenDedupe-from-a-previous-version-to-v3-6/m-p/852543

Disk Targets

The disk target software versions listed in this section are the minimum software levels that are supported. Where more than one software level is listed, this implies a newer version has been tested. The earlier software version is the minumum version required.

Cloud storage providers will be individually certified for use with Backup Exec, therefore, additional Cloud providers will be added as they are certified.

Go to Top of "Disk Targets"

Amazon Web Services

Storage GatewayRelease DateConnectivityVirtualization Platform
Gateway-Cached Volume [1][2][3]16-Dec-2014iSCSIVMware ESXi
Microsoft Hyper-V [4]
  • f18-1
  • f18-2
  • f18-3
  • f18-4
  1. The Gateway-Cached Volume is offered as a service and therefore specific software versions are not available. Please refer to release dates: http://aws.amazon.com/releasenotes/AWS-Storage-Gateway
  2. Backup Exec Simplified Disaster Recovery (SDR) is not supported.
  3. See the Amazon Disk Targets section also
  4. Please refer to AWS documentation for hypervisor and host requirements: http://docs.aws.amazon.com/storagegateway/latest/userguide/Requirements.html
Go to Top of "Disk Targets"

Microsoft StorSimple

Storage GatewayMinimum Supported VersionSupported Cloud ProvidersConnectivityVirtualization Platform
8100/8600 [1][2][3]StorSimple Update 3AzureiSCSIVMware ESXi
Microsoft Hyper-V
  • f19-1
  • f19-2
  • f19-3
  1. Please refer to MS documentation: https://docs.microsoft.com/en-us/azure/storsimple/storsimple-configure-backup-target-using-backup-exec
  2. Backup Exec Simplified Disaster Recovery (SDR) is not supported.
  3. See the Microsoft Disk Targets section also
Go to Top of "Disk Targets"

NetApp

FamilyFamily MembersSoftware TestedSupported Cloud ProvidersConnectivityBasic B2DGRT Tested
AltaVault Appliance [1][2][3]AVA-400, AVA-8004.2.2Amazon S3CIFS
  • f20-1
  • f20-2
  • f20-3
AltaVault Virtual Appliance [1][2][3]AAVA-v2, AVA-v8, AVA-v16, AVA-v324.2.2Amazon S3CIFS
  • f20-1
  • f20-2
  • f20-3
AltaVault Cloud Appliance [1][2][3]AVA-c4, AVA-c8, AVA-c164.2.2Amazon S3CIFS
  • f20-1
  • f20-2
  • f20-3
  1. Backup Exec Simplified Disaster Recovery (SDR) is not supported. Refer to the AltaVault docs for recovery instructions.
  2. NetApp AltaVault Cloud Integrated Storage Deployment Guide 4.0.1: https://library.netapp.com/ecm/ecm_download_file/ECMP12510036
  3. See the NetApp Disk Targets section also
Go to Top of "Disk Targets"

Riverbed

FamilyFamily MembersSoftware TestedSupported Cloud ProvidersConnectivityBasic B2DGRT Tested
SteelStore Appliance [1][2][3]WWA730, WWA2030, WWA3030SteelStore OS 3.0.2, 3.1.2a, 3.3Amazon S3, Microsoft AzureCIFS
  • f21-1
  • f21-2
  • f21-3
SteelStore Virtual Appliance [1][2][3]SteelStore Virtual 110, SteelStore Virtual 210, SteelStore Virtual 410, SteelStore Virtual 810, SteelStore Virtual 1610SteelStore OS 3.1.1a, 3.1.2a, 3.3Amazon S3, Microsoft AzureCIFS
  • f21-1
  • f21-2
  • f21-3
Whitewater Appliance [1][2][3]WWA510, WWA710, WWA2010, WWA3010SteelStore OS 3.0.2, 3.1.2a, 3.3Amazon S3, Microsoft AzureCIFS
  • f21-1
  • f21-2
  • f21-3
  1. Backup Exec Simplified Disaster Recovery (SDR) is not supported. Refer to the SteelStore docs for recovery instructions.
  2. SteelStore Solution Guide: http://media-cms.riverbed.com/documents/Solution+Guide+-+SteelStore+with+Backup+Exec+3.1.1.pdf
  3. See the Riverbed Disk Targets section also

VTL

The Cloud Virtual Tape Library (VTL) device support information is listed below. Please Note:
1. Configure the virtual device with the unique inquiry string as listed in this document. Emulating other devices is not supported.
2. Tested iSCSI versions of virtual tape libraries are listed in the "iSCSI Solutions" section, under the "SAN Infrastructure components" bookmark. Please reference the limitations listed in that section.

Go to Top of "VTL"

Amazon Web Services

Storage GatewayRelease DateConnectivityVirtualization PlatformLibrary Inquiry
Drive Inquiry
Gateway-Virtual Tape Library [1][2][3][4][5]16-Dec-2014iSCSI VMware ESXi
Microsoft Hyper-V
AWS EC2 [6][7][8]
AWS^^^^^Gateway-VTL
IBM^^^^^ULT3580-TD5
  • f22-1
  • f22-2
  • f22-3
  • f22-4
  • f22-5
  • f22-6
  • f22-7
  • f22-8
  1. Please read through the Best Practice guide for the Gateway-VTL before deployment: http://www.veritas.com/docs/000024278
  2. The Storage Gateway is offered as a service and therefore specific software versions are not available. Please refer to release dates: http://aws.amazon.com/releasenotes/AWS-Storage-Gateway
  3. For the AWS Storage Gateway-VTL user guide, please refer to: http://docs.aws.amazon.com/storagegateway/latest/userguide/gateway-vtl.html
  4. Backup Exec Simplified Disaster Recovery (SDR) is not supported.
  5. See the Amazon iSCSI VTL section also
  6. Please refer to AWS documentation for hypervisor and host requirements: http://docs.aws.amazon.com/storagegateway/latest/userguide/Requirements.html
  7. For information on the AWS Storage Gateway in EC2 please refer to the following documentation: https://aws.amazon.com/marketplace/pp/B00AZ4Q6MM
  8. Import operations are limited to 64 tapes at a time. Please see https://www.veritas.com/support/en_US/article.100043731.html

Disk Targets

For this basic support, any device recognized and supported by the Windows platform should work with Backup Exec. Mapped network drives are not supported. UNC paths are supported. The disk devices listed in these two sections have been tested with Backup Exec as a result of a formal joint business agreement and OEM relationship, but are not intended to be a complete list of compatible devices.

For "basic" disk storage capabilities, Backup Exec does not exclude or block recognition for disk devices. Basic disk storage devices can be seen in the Disk Storage and Disk Cartridge sections. This information is organized by vendor and provides information on the storage devices tested, the Inquiry Strings (if applicable), the type of interface, media type, and any special notes on a per device basis.

If the desired device is not already listed in this section, customers are encouraged to run the B2D test tool to verify their desired device's level of functionality. If Backup Exec is not already installed, the B2D test tool can be downloaded from http://www.veritas.com/docs/000037869. Instructions for use are in that same technote. Backup Exec Technical Support will be unable to offer assistance if the device experiences failures during the B2Dtest and the customer should contact the hardware vendor for advice and assistance.

Devices running the Windows Unified Data Storage Server OS which provides iSCSI target functionality are supported per the Software Compatibility List. See http://www.veritas.com/docs/000115689 for supported operating system details.

Devices running the Windows Storage Server OS (sometimes referred to as a NAS) can be used as a Backup Exec Media Server if the operating system version is on the Software Compatibility List (SCL). Some examples are the Dell NX3200, the HPE StoreEasy series, and others. If the server meets the prerequisites for adding the Backup Exec Deduplication Option, then that server's local disks can be used for deduplication by that Backup Exec Media Server. See http://www.backupexec.com/compatibility for supported operating system details.
If the server vendor supports the server as an iSCSI target, then it can be supported for remote deduplication storage from other Backup Exec Media Servers. Refer to the HCL Disk Storage section for tested systems, but other systems would be supported also. Please see the deduplication best practices document at https://www.veritas.com/content/support/en_US/doc/72686287-131623464-0/v70445236-131623464
A server running Windows Storage Server is NOT supported for OpenStorage (OST) target storage use, unless that server/appliance appears in the OST section of the HCL. A server running Windows Storage Server may be used with the Remote Agent for Windows Servers (RAWS) to send data to an OST appliance.

For more advanced disk capabilities, refer to the OST-Appliance section or VSS Providers for Offhost backup sections. The presence of the disk device in these advanced sections is required for support.

Go to Top of "Disk Targets"

Granular Restore Technology (GRT) support, per deduplication type

Deduplication typeGRT support method
Backup Exec Deduplication Disk StorageNon-GRT and GRT backups are supported and no staging is needed for GRT restores.
Hardware based deduplication OpenStorage appliances 1. Non-GRT and GRT backup are supported but staging is needed at time of GRT restores. Backups will be faster and restores slower (due to staging).
2. Alternately if the device supports it then one can create B2D using CIFS share and then run backups. Backups will be slower but GRT restores will be faster.
NBU50x0 applianceNon-GRT and GRT backups are supported and no staging is needed for GRT restores.
Pure Disk appliance, also known as Classic Pure DiskNon-GRT and GRT backups are supported and no staging is needed for GRT restores.

Disk Storage

Go to Top of "Disk Storage"

Disk Device Legend

ValueMeaning
ConnectivityThe method by which the device communicates with the Backup Exec server.
Character used to denote successful completion of acceptance testing for the item listed in the column.
Basic B2DBasic functionality of a device as it relates to being used as a Backup-to-Disk device (Disk Storage) in Backup Exec. Backup Exec's Granular Restore Technology (GRT) is not included in Basic B2D.
GRT Tested Granular Restore Technology (GRT) has been validated specifically for this device.
The presence of a checkmark in this column indicates that no staging is needed for GRT restores.
The presence of an "S" in this column indicates that staging may be needed at time of GRT restores. This is typically exhibited with CIFS connectivity.
BEDedupBackup Exec Deduplication is the native method for deduplication - enabled via an additional "Backup Exec Deduplication Option", and referred to as "Backup Exec Deduplication Disk Storage".
Only Local disks may be used for deduplication storage. Removable interfaces like USB and FireWire are also not supported due to the perceived temporary connection method and issues that can arise from a device that is unsafely removed or appears on a different path. For Devices with a supported interface the absence of a check here does not signify that the device will not be supported, merely that deduplication tests have not been run in combination with this device. See comments above regarding, "not intended to be a complete list of compatible devices". The Backup Exec Deduplication Option is recommended for use on a dedicated / non-removable volume as the location to store the deduplication disk storage. For this reason, there are no dedup checkboxes in the Disk Cartridge device section.
While possible, the usage of the "Backup Exec Deduplication Option" with USB, FireWire, and remote disks implies the customer is doing so at their own risk and without official Veritas support.
Go to Top of "Disk Storage"

Amazon

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
AWS Gateway-Cached Volume [1]iSCSIAWS Gateway-Cached Volume
  • f25-1
  1. This device includes Cloud features. Please see the Amazon Cloud Storage section for specifics.
Go to Top of "Disk Storage"

BlueArc

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
Mercury seriesCIFSMercury 50, Mercury 100
Go to Top of "Disk Storage"

Buffalo

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
LinkStation 400 SeriesCIFSSLinkStation 410, LinkStation 420, LinkStation 420s, LinkStation 421, LinkStation 441
LinkStation Pro/DUO SeriesCIFSSLinkStation Pro DUO Enclosure, LS-WVL, LS-WXL
Quad - HD-QLSU2R5eSATAQuad - HD-QLSU2R5
TeraStation 3000CIFSSTeraStation 3400, TeraStation 3400r Rackmount
TeraStation 3000iSCSITeraStation 3400, TeraStation 3400r Rackmount
TeraStation 3010 seriesCIFSSTeraStation 3210DN, TeraStation 3410DN, TeraStation 3410RN
TeraStation 3010 seriesiSCSITeraStation 3210DN, TeraStation 3410DN, TeraStation 3410RN
TeraStation 5000CIFSSTeraStation 5200, TeraStation 5400, TeraStation 5400r Rackmount, TeraStation 5600, TeraStation 5800
TeraStation 5000iSCSITeraStation 5200, TeraStation 5400, TeraStation 5400r Rackmount, TeraStation 5600, TeraStation 5800
TeraStation 5010 seriesCIFSSTeraStation 5210DF, TeraStation 5210DN, TeraStation 5410DN, TeraStation 5410RN, TeraStation 5810DN, TeraStation 51210RH
TeraStation 5010 seriesiSCSITeraStation 5210DF, TeraStation 5210DN, TeraStation 5410DN, TeraStation 5410RN, TeraStation 5810DN, TeraStation 51210RH
TeraStation 7000CIFSSTeraStation 7120r, TeraStation 7120r Enterprise
TeraStation 7000iSCSITeraStation 7120r, TeraStation 7120r Enterprise
TeraStation IIICIFSSTS-RXL/R5, TS-XL/R5
TeraStation III iSCSIiSCSITS-IXL/R5, TS-RIXL/R5
TeraStation ProCIFSSTeraStation Pro
Go to Top of "Disk Storage"

Dell EMC

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
Compellent FS8600CIFSSCompellent FS8600
Compellent Storage Center 5Fibre ChannelCompellent Storage Center 5.2, Compellent Storage Center 5.3, Compellent Storage Center 5.4
Compellent Storage Center 5iSCSICompellent Storage Center 5.2, Compellent Storage Center 5.3, Compellent Storage Center 5.4
DL3D seriesCIFSSDL1500, DL3000
DR SeriesCIFSSDR4000, DR4100, DR6000
EqualLogic FS7500CIFSSEqualLogic FS7500
EqualLogic FS7600CIFSSEqualLogic FS7600
EqualLogic FS7610CIFSSEqualLogic FS7610
EqualLogic PS3000 seriesiSCSIEqualLogic PS3000E, EqualLogic PS3000X, EqualLogic PS3000XV
EqualLogic PS4000 seriesiSCSIEqualLogic PS4000E, EqualLogic PS4000X, EqualLogic PS4000XV, EqualLogic PS4100E, EqualLogic PS4100X, EqualLogic PS4100XV, EqualLogic PS4100XV3.5"
EqualLogic PS5000 seriesiSCSIEqualLogic PS5000E, EqualLogic PS5000X, EqualLogic PS5000XV, EqualLogic PS5500E
EqualLogic PS6000 seriesiSCSIEqualLogic PS6000E, EqualLogic PS6000S, EqualLogic PS6000X, EqualLogic PS6000XV, EqualLogic PS6000XVS, EqualLogic PS6010E, EqualLogic PS6010S, EqualLogic PS6010X, EqualLogic PS6010XV, EqualLogic PS6010XVS, EqualLogic PS6100E, EqualLogic PS6100X, EqualLogic PS6100XV, EqualLogic PS6100XV3.5", EqualLogic PS6500E, EqualLogic PS6500X, EqualLogic PS6500XV, EqualLogic PS6510E, EqualLogic PS6510X, EqualLogic PX6100S, EqualLogic PX6100XS
Iomega StorCenter ix series network storageCIFSIomega StorCenter ix2-200, Iomega StorCenter ix4-200d, Iomega StorCenter ix12-300r, Iomega StorCenter Pro ix4-200r
Iomega StorCenter px series network storageiSCSIIomega StorCenter px4-300d, Iomega StorCenter px4-300r, Iomega StorCenter px6-300d, Iomega StorCenter px12-350r
PowerVault DL2000SASPowerVault DL2000
PowerVault DL2100SASPowerVault DL2100
PowerVault DL2200SASPowerVault DL2200
PowerVault MD30xx SeriesiSCSIPowerVault MD3000, PowerVault MD3000i
PowerVault MD30xx SeriesSASPowerVault MD3000, PowerVault MD3000i
PowerVault MD1000SASPowerVault MD1000
PowerVault MD1200SASPowerVault MD1200
PowerVault NX3500CIFSSPowerVault NX3500
PowerVault NX3600CIFSSPowerVault NX3600
PowerVault NX3610CIFSSPowerVault NX3610
VNX2e seriesCIFSVNXe1600, VNXe3200
Go to Top of "Disk Storage"

Dell EMC Data Domain

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
Appliance seriesCIFSSDD140, DD160, DD510, DD530, DD560, DD565, DD580, DD610, DD620, DD630, DD640, DD660, DD670, DD690, DD860, DD880, DD890, DD990, DD2200, DD2500, DD3300, DD4200, DD4500, DD6300, DD6800, DD7200, DD9300, DD9500, DD9800
Virtual Edition (Hyper-V)CIFSSVirtual Edition (Hyper-V)
Virtual Edition (VMware)CIFSSVirtual Edition (VMware)
Go to Top of "Disk Storage"

Drobo

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
5NCIFSS5N
B800iiSCSIB800i
B810iiSCSIB810i
B810nCIFSSB810n
B1200iiSCSIB1200i
DroboUSBDrobo
DroboEliteiSCSIDroboElite
DroboEliteUSBDroboElite
DroboProiSCSIDroboPro
DroboProUSBDroboPro
Go to Top of "Disk Storage"

Exablox

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
OneBloxCIFSOneBlox
Go to Top of "Disk Storage"

ExaGrid

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
EX seriesCIFSSEX1000, EX2000, EX3000, EX4000, EX5000, EX7000, EX7000-SEC, EX10000E, EX10000E-SEC, EX13000E, EX13000E-SEC, EX21000E, EX21000E-SEC, EX32000E, EX32000E-SEC, EX40000E, EX40000E-SEC, EX63000E, EX63000E-SEC
Go to Top of "Disk Storage"

Fujitsu

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
ETERNUS DX100/DX200 seriesCIFSSETERNUS AF250 S2, ETERNUS DX60 S3, ETERNUS DX100 S3, ETERNUS DX200 S3
ETERNUS DX500/DX600 seriesCIFSSETERNUS AF650 S2, ETERNUS DX500 S3, ETERNUS DX500 S4, ETERNUS DX600 S3, ETERNUS DX600 S4
Go to Top of "Disk Storage"

H3C

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
CP3310CIFSSCP3310
CP3352CIFSSCP3352
CP3354CIFSSCP3354
CP5510CIFSSCP5510
CP5550CIFSSCP5550
CP6660CIFSSCP6660
Go to Top of "Disk Storage"

Hewlett Packard Enterprise

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
D2D4xxx iSCSI seriesiSCSID2D4106i Backup System
D2D4xxx seriesCIFSD2D4004fc Backup System, D2D4104fc Backup System, D2D4106fc Backup System, D2D4112 Backup System, D2D4312 Backup System, D2D4324 Backup System
D2D25xx seriesCIFSSD2D2502i Backup System, D2D2503i Backup System, D2D2504i Backup System
D2D4100 G2 Backup SystemCIFSSD2D4106fc G2 Backup System, D2D4106i G2 Backup System, D2D4112 G2 Backup System
EVA4400/6400/8400 seriesFibre ChannelEVA4400, EVA6400, EVA8400
P2000 G3 MSA seriesFibre ChannelP2000 G3 FC, P2000 G3 FC/iSCSI, P2000 G3 iSCSI, P2000 G3 SAS
P2000 G3 MSA seriesiSCSIP2000 G3 FC, P2000 G3 FC/iSCSI, P2000 G3 iSCSI, P2000 G3 SAS
P2000 G3 MSA seriesSASP2000 G3 FC, P2000 G3 FC/iSCSI, P2000 G3 iSCSI, P2000 G3 SAS
StoreEasy 1000 seriesCIFSSStoreEasy 1430, StoreEasy 1440, StoreEasy 1450, StoreEasy 1530, StoreEasy 1540, StoreEasy 1550, StoreEasy 1630, StoreEasy 1640, StoreEasy 1650, StoreEasy 1830, StoreEasy 1840, StoreEasy 1850
StoreEasy 1000 seriesiSCSIStoreEasy 1430, StoreEasy 1440, StoreEasy 1450, StoreEasy 1530, StoreEasy 1540, StoreEasy 1550, StoreEasy 1630, StoreEasy 1640, StoreEasy 1650, StoreEasy 1830, StoreEasy 1840, StoreEasy 1850
StoreEasy 3000 Gateway Blade seriesCIFSSStoreEasy 3850 Gateway Storage Blade, StoreEasy 3850 WSS2016 Gateway Storage Blade
StoreEasy 3000 Gateway Blade seriesiSCSIStoreEasy 3850 Gateway Storage Blade, StoreEasy 3850 WSS2016 Gateway Storage Blade
StoreEasy 3000 Gateway seriesCIFSSStoreEasy 3830 Gateway, StoreEasy 3840 Gateway
StoreEasy 3000 Gateway seriesiSCSIStoreEasy 3830 Gateway, StoreEasy 3840 Gateway
StoreEasy 5000 seriesCIFSSStoreEasy 5530
StoreEasy 5000 seriesiSCSIStoreEasy 5530
StoreOnce 2000 seriesCIFSSStoreOnce 2610, StoreOnce 2620, StoreOnce 2700, StoreOnce 2900
StoreOnce 3000 seriesCIFSSStoreOnce 3100
StoreOnce 3500/3600 seriesCIFSSStoreOnce 3520, StoreOnce 3540, StoreOnce 3620, StoreOnce 3640
StoreOnce 4000 seriesCIFSSStoreOnce 4210fc, StoreOnce 4210i, StoreOnce 4220, StoreOnce 4420, StoreOnce 4430, StoreOnce 4500, StoreOnce 4700, StoreOnce 4900
StoreOnce 5000 seriesCIFSSStoreOnce 5100, StoreOnce 5200, StoreOnce 5250, StoreOnce 5500, StoreOnce 5650
StoreOnce 6000 seriesCIFSSStoreOnce 6500, StoreOnce 6600, StoreOnce B6200
StoreOnce VSA (Hyper-V) [1]CIFSSStoreOnce VSA (Hyper-V)
  • f35-1
StoreOnce VSA (VMware) [1]CIFSSStoreOnce VSA (VMware)
  • f35-1
  1. StoreOnce VSA is a virtual appliance. For device details and platform support refer to: https://www.hpe.com/h20195/v2/GetDocument.aspx?docname=c04328820
Go to Top of "Disk Storage"

Hitachi

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
Capacity Optimization (HCO) [1]CIFSSHCO 210, HCO 230
  • f36-1
Data Ingestor (HDI)CIFSSData Ingestor (HDI)
NAS Platform, 4000 and 3000 SeriesCIFSHNAS 3080 (M1), HNAS 3090 (M2), HNAS 4040, HNAS 4060, HNAS 4080, HNAS 4100
NAS Platform F1000 (HNAS F1000)CIFSSHNAS F1120, HNAS F1140
SMS/AMS2000 seriesFibre ChannelAMS2100, AMS2300, AMS2500, SMS100
Virtual File Platform (VFP)CIFSSVFP 50, VFP 70, VFP 80, VFP 100N, VFP 110, VFP 200N, VFP 300N, VFP 500N, VFP 600N, VFP 2010, VFP 2100, VFP 2300
  1. GRT is not recommended when the microcode version of HCO is 2.1
Go to Top of "Disk Storage"

IBM

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
System Storage TS7600 series with ProtecTIERCIFSSSystem Storage TS7620, System Storage TS7650AP1, System Storage TS7650G
Go to Top of "Disk Storage"

Imation

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
DataGuard Appliances [1]CIFSSR4, T5R
  • f38-1
DataGuard Appliances [1]iSCSIR4, T5R
  • f38-1
Nexsan E-Series SystemsFibre ChannelNexsan E18, Nexsan E48, Nexsan E60
Nexsan E-Series SystemsiSCSINexsan E18, Nexsan E48, Nexsan E60
Nexsan E-Series V SystemsFibre ChannelNexsan E18V System, Nexsan E32V System, Nexsan E48V System, Nexsan E60V System
Nexsan E-Series V SystemsiSCSINexsan E18V System, Nexsan E32V System, Nexsan E48V System, Nexsan E60V System
Nexsan NST5000CIFSSNexsan NST5000
Nexsan NST5000iSCSINexsan NST5000
Nexsan NST6000CIFSSNexsan NST6000
Nexsan NST6000iSCSINexsan NST6000
  1. Please note: this device is nearing the end of support. Please see the 'Retiring Soon' section.
Go to Top of "Disk Storage"

Infortrend

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
EonNAS 3000 seriesCIFSSEonNAS 3000 series
EonStor DS FC seriesFibre ChannelEonStor DS FC series
EonStor DS iSCSI seriesiSCSIEonStor DS iSCSI series
Go to Top of "Disk Storage"

LaCie

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
5big Storage ServeriSCSI5big Storage Server
12big Rack NetworkiSCSI12big Rack Network
12big Rack NetworkUSB12big Rack Network
Go to Top of "Disk Storage"

Lenovo

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
DS SeriesiSCSIDS2200, DS4200, DS6200
Go to Top of "Disk Storage"

Microsoft

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
StorSimple 8100/8600 series [1]iSCSIStorSimple 8100, StorSimple 8600
  • f42-1
  1. This device includes Cloud features. Please see the Microsoft StorSimple section for specifics.
Go to Top of "Disk Storage"

NEC

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
HYDRAstor HS3 and HS8 (2nd Gen) and iStorage HS3 and HS8 (2nd Gen)CIFSSHYDRAstor HS3-210, HYDRAstor HS8-2002S, HYDRAstor HS8-2004R, HYDRAstor HS8-2004S, HYDRAstor HS8-2010R, HYDRAstor HS8-2020R, HYDRAstor HS8-2110R, iStorage HS3-20T, iStorage HS8-20R, iStorage HS8-20S
HYDRAstor HS3 and HS8 (3rd Gen), iStorage HS3 and HS8 (3rd Gen) and NEC Storage HS3 (3rd Gen)CIFSSHYDRAstor HS3-310, HYDRAstor HS8-3002S, HYDRAstor HS8-3004R, HYDRAstor HS8-3004S, HYDRAstor HS8-3010R, HYDRAstor HS8-3020R, HYDRAstor HS8-3110R, iStorage HS3-30T, iStorage HS3-30T2, iStorage HS8-30R, iStorage HS8-30S, NEC Storage HS3-30
HYDRAstor HS3 and HS8 (4th Gen), iStorage HS3 and HS8 (4th Gen) and NEC Storage HS3 and HS8 (4th Gen)CIFSSHYDRAstor HS3-410, HYDRAstor HS8-4001S, HYDRAstor HS8-4002S, HYDRAstor HS8-4006R, HYDRAstor HS8-4165, iStorage HS3-40, iStorage HS8-40, NEC Storage HS3-40, NEC Storage HS8-40
Go to Top of "Disk Storage"

NetApp

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
AltaVault [1][2][3]CIFSAVA-400, AVA-800, AVA-c4, AVA-c8, AVA-c16, AVA-v2, AVA-v8, AVA-v16, AVA-v32
  • f44-1
  • f44-2
  • f44-3
  1. Backup Exec Simplified Disaster Recovery (SDR) is not supported. Refer to the NetApp AltaVault docs for recovery instructions.
  2. NetApp AltaVault Cloud Integrated Storage Deployment Guide 4.0.1: https://library.netapp.com/ecm/ecm_download_file/ECMP12510036
  3. This device includes Cloud features. Please see the NetApp Cloud Storage section for specifics.
Go to Top of "Disk Storage"

NETGEAR

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
NV+CIFSNV+
ReadyNAS 100 SeriesCIFSSReadyNAS 102, ReadyNAS 104
ReadyNAS 100 SeriesiSCSIReadyNAS 102, ReadyNAS 104
ReadyNAS 300 SeriesCIFSSReadyNAS 312, ReadyNAS 314, ReadyNAS 316
ReadyNAS 300 SeriesiSCSIReadyNAS 312, ReadyNAS 314, ReadyNAS 316
ReadyNAS 500 SeriesCIFSSReadyNAS 516
ReadyNAS 500 SeriesiSCSIReadyNAS 516
ReadyNAS 700 SeriesCIFSSReadyNAS 716
ReadyNAS 700 SeriesiSCSIReadyNAS 716
ReadyNAS 1100CIFSSReadyNAS 1100
ReadyNAS 2000 SeriesCIFSSReadyNAS 2120
ReadyNAS 2000 SeriesiSCSIReadyNAS 2120
ReadyNAS 2100CIFSSReadyNAS 2100
ReadyNAS 2100iSCSIReadyNAS 2100
ReadyNAS 3000 SeriesCIFSSReadyNAS 3220
ReadyNAS 3000 SeriesiSCSIReadyNAS 3220
ReadyNAS 3100CIFSSReadyNAS 3100
ReadyNAS 3100iSCSIReadyNAS 3100
ReadyNAS 3200CIFSSReadyNAS 3200
ReadyNAS 3200iSCSIReadyNAS 3200
ReadyNAS 4000 SeriesCIFSSReadyNAS 4220
ReadyNAS 4000 SeriesiSCSIReadyNAS 4220
ReadyNAS 4200CIFSSReadyNAS 4200
ReadyNAS 4200iSCSIReadyNAS 4200
ReadyNAS NVXCIFSSReadyNAS NVX
ReadyNAS NVXiSCSIReadyNAS NVX
ReadyNAS ProCIFSSReadyNAS Pro
ReadyNAS ProiSCSIReadyNAS Pro
Go to Top of "Disk Storage"

Nexsan

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
Beast Systems [1]Fibre ChannelSASBeast, SATABeast, SATABeast2
  • f46-1
Beast Systems [1]iSCSISASBeast, SATABeast, SATABeast2
  • f46-1
Boy Systems [1]Fibre ChannelSASBoy, SATABoy2
  • f46-1
Boy Systems [1]iSCSISASBoy, SATABoy2
  • f46-1
E-SeriesFibre ChannelBEAST, E-Series 18 (E18), E-Series 18P (E18P), E-Series 18V (E18V), E-Series 32V (E32V), E-Series 48 (E48), E-Series 48P (E48P), E-Series 48V (E48V), E-Series 48VT (E48VT), E-Series 60 (E60), E-Series 60P (E60P), E-Series 60V (E60V), E-Series 60VT (E60VT), NST5000, NST6000, SATABeast 2.5
E-SeriesiSCSIBEAST, E-Series 18 (E18), E-Series 18P (E18P), E-Series 18V (E18V), E-Series 32V (E32V), E-Series 48 (E48), E-Series 48P (E48P), E-Series 48V (E48V), E-Series 48VT (E48VT), E-Series 60 (E60), E-Series 60P (E60P), E-Series 60V (E60V), E-Series 60VT (E60VT), NST5000, NST6000, SATABeast 2.5
SATABoy [1]Fibre ChannelSATABoy
  • f46-1
SATABoy [1]iSCSISATABoy
  • f46-1
  1. Please note: this device is nearing the end of support. Please see the 'Retiring Soon' section.
Go to Top of "Disk Storage"

Oracle

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
ZFS Storage Appliance seriesCIFSSZFS Storage 7110, ZFS Storage 7120, ZFS Storage 7210, ZFS Storage 7310, ZFS Storage 7320, ZFS Storage 7410, ZFS Storage 7420, ZFS Storage ZS3-2, ZFS Storage ZS3-4, ZFS Storage ZS4-4, ZFS Storage ZS5-2, ZFS Storage ZS5-4
Go to Top of "Disk Storage"

Overland Storage

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
SnapServer DXCIFSSSnapServer DX1, SnapServer DX2, SnapServer XSD 40, SnapServer XSR 40, SnapServer XSR 120
SnapServer DXiSCSISnapServer DX1, SnapServer DX2, SnapServer XSD 40, SnapServer XSR 40, SnapServer XSR 120
Go to Top of "Disk Storage"

Pure Storage

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
FlashBladeCIFSSFlashBlade
Go to Top of "Disk Storage"

QNAP

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
Business NAS seriesCIFSSTS-809 series, TS-x39 series, TS-x59 series, TS-x69 series, TS-x79 series
Business NAS seriesiSCSITS-809 series, TS-x39 series, TS-x59 series, TS-x69 series, TS-x79 series
Go to Top of "Disk Storage"

Quantum

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
DXi4700 SeriesCIFSSDXi4701
DXi4800 SeriesCIFSSDXi4800
DXi6700 SeriesCIFSSDXi6700, DXi6701, DXi6702
DXi6800 SeriesCIFSSDXi6802
DXi6900 SeriesCIFSSDXi6900, DXi6900-S
DXi8500 SeriesCIFSSDXi8500, DXi8500 2TB, DXi8500 3TB
DXi9000 SeriesCIFSSDXi9000
DXi V Series [1]CIFSSDXi V1000, DXi V2000, DXi V4000
  • f51-1
  1. This device is a virtual appliance. Representative VMware-supported ESX4, ESXi4, or ESXi5 servers/storage were tested. Refer to http://downloads.quantum.com/dxiv1000/6-67611-01_DXi_V1000_QuickStartGuide_RevA.pdf
Go to Top of "Disk Storage"

Quest

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
DR 11g SeriesCIFSSDR4000
DR 12g SeriesCIFSSDR4100, DR6000
DR 13g SeriesCIFSSDR4300, DR4300e, DR6300
Go to Top of "Disk Storage"

Riverbed

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
SteelStore Series [1][2][3]CIFSSteelStore 730, SteelStore 2030, SteelStore 3030
  • f53-1
  • f53-2
  • f53-3
SteelStore Virtual Appliance [1][2][3]CIFSSteelStore Virtual 110, SteelStore Virtual 210, SteelStore Virtual 410, SteelStore Virtual 810, SteelStore Virtual 1610
  • f53-1
  • f53-2
  • f53-3
WhiteWater Series [1][2][3]CIFSWhiteWater 510, WhiteWater 710, WhiteWater 2010, WhiteWater 3010
  • f53-1
  • f53-2
  • f53-3
  1. Backup Exec Simplified Disaster Recovery (SDR) is not supported. Refer to the SteelStore docs for recovery instructions.
  2. SteelStore Solution Guide: http://media-cms.riverbed.com/documents/Solution+Guide+-+SteelStore+with+Backup+Exec+3.1.1.pdf
  3. This device includes Cloud features. Please see the Riverbed Cloud Storage section for specifics.
Go to Top of "Disk Storage"

Synology

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
Home to Business Workgroup ValueCIFSSDS114, DS116, DS214, DS214play, DS216, DS216play, DS414, DS415play, DS715, DS1515, RS214, RS814
Home to Business Workgroup ValueiSCSIDS114, DS116, DS214, DS214play, DS216, DS216play, DS414, DS415play, DS715, DS1515, RS214, RS814
Home to Small Office JCIFSSDS115j, DS213air, DS213j, DS214se, DS216j, DS216se, DS414j, DS414slim, DS416j, DS416slim, DS715
Home to Small Office JiSCSIDS115j, DS213air, DS213j, DS214se, DS216j, DS216se, DS414j, DS414slim, DS416j, DS416slim, DS715
Large Scale Business XS/XS+CIFSSDS365xs, DS2015xs, DS3612xs, RC18015xs+, RS3412RPxs, RS3412xs, RS3413xs+, RS3614RPxs, RS3614xs, RS3614xs+, RS10613xs+, RS18016xs+
Large Scale Business XS/XS+iSCSIDS365xs, DS2015xs, DS3612xs, RC18015xs+, RS3412RPxs, RS3412xs, RS3413xs+, RS3614RPxs, RS3614xs, RS3614xs+, RS10613xs+, RS18016xs+
Small and Medium Business PlusCIFSSDS112+, DS213+, DS214+, DS215+, DS216+, DS216+II, DS412+, DS415+, DS713+, DS716+, DS716+II, DS916+, DS1513+, DS1515+, DS1813+, DS1815+, DS2413+, DS2415+, RS812+, RS812RP+, RS814, RS814+, RS814RP+, RS2414+, RS2414RP+, RS2416+, RS2416RP+, RS2418+, RS2418RP+
Small and Medium Business PlusiSCSIDS112+, DS213+, DS214+, DS215+, DS216+, DS216+II, DS412+, DS415+, DS713+, DS716+, DS716+II, DS916+, DS1513+, DS1515+, DS1813+, DS1815+, DS2413+, DS2415+, RS812+, RS812RP+, RS814, RS814+, RS814RP+, RS2414+, RS2414RP+, RS2416+, RS2416RP+, RS2418+, RS2418RP+
Go to Top of "Disk Storage"

Tandberg

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
BizNAS D400/R400CIFSSBizNAS D400, BizNAS D408, BizNAS R400, BizNAS R408
BizNAS D400/R400iSCSIBizNAS D400, BizNAS D408, BizNAS R400, BizNAS R408
DPS2000 Series NASCIFSSDPS2040, DPS2140, DPS2142

Disk Cartridge

Note: Granular Restore Technology (GRT) is not supported on disk cartridge devices if the backup spans media.

Note: USB 3.0 devices are supported (when available from the vendor).

Note: To view the disk inquiry string: Open Computer Management, Go to Device Manager | Disk drives, Double click on the RDX drive, Click on the Details tab, For the Property drop-down, select ‘Hardware Ids’, View the inquiry string in the Value section

Go to Top of "Disk Cartridge"

Disk Device Legend

ValueMeaning
^Character used to denote a space in the INQUIRY STRING.
Character used to denote support for the item listed in the column.
WinBESThe listed device is supported directly attached to a Windows Backup Exec Server platform. See the SCL ( http://www.veritas.com/docs/000115689) for supported Windows Server Operating System platforms.
Go to Top of "Disk Cartridge"

actidata

DeviceInquiry StringDrive InterfaceMediaWinBES
actiDisk RDXIMATION^RDXSATAdisk
actiDisk RDXIMATION^RDXUSBdisk
Go to Top of "Disk Cartridge"

BDT

DeviceInquiry StringDrive InterfaceMediaWinBES
RDStorBDT^^^^^RDXiSCSIdisk
Go to Top of "Disk Cartridge"

Dell EMC

DeviceInquiry StringDrive InterfaceMediaWinBES
RD1000Dell^^^^RD1000SATAdisk
RD1000Dell^^^^RD1000USBdisk
Go to Top of "Disk Cartridge"

Hewlett Packard Enterprise

DeviceInquiry StringDrive InterfaceMediaWinBES
RDX [1]HP^^^^^^RDXUSBdisk
  • f60-1
  1. Requires the use of the HPE RDX utility from http://www.hp.com/support/rdx for proper eject functionality.
Go to Top of "Disk Cartridge"

IBM

DeviceInquiry StringDrive InterfaceMediaWinBES
RDXIBM^^^^^RDXUSBdisk
Go to Top of "Disk Cartridge"

Imation

DeviceInquiry StringDrive InterfaceMediaWinBES
LR1100 RDX 1U Storage EnclosureIMATION^RDX-USB3USBdisk
RDX A8IMATION^RDX^A8iSCSIdisk
RDX Removable HDD SystemIMATION^RDXSATAdisk
RDX Removable HDD SystemIMATION^RDXUSBdisk
RDX USB 3.0IMATION^RDX-USB3USBdisk
Go to Top of "Disk Cartridge"

Lenovo

DeviceInquiry StringDrive InterfaceMediaWinBES
Internal USB RDXLENOVO^^RDXUSBdisk
Go to Top of "Disk Cartridge"

ProStor

DeviceInquiry StringDrive InterfaceMediaWinBES
RDXProStor^RDXSATAdisk
Go to Top of "Disk Cartridge"

Quantum

DeviceInquiry StringDrive InterfaceMediaWinBES
RDXQUANTUM^RDXUSBdisk
RDX 8000QUANTUM^RDX8000iSCSIdisk
RDX USB 3.0QUANTUM^RDX-USB3USBdisk
Go to Top of "Disk Cartridge"

Tandberg

DeviceInquiry StringDrive InterfaceMediaWinBES
RDXTANDBERGRDXSATAdisk
RDXTANDBERGRDXUSBdisk
RDX QuikStationVRDX^^^^RMVBL_VDISKiSCSIdisk
RDX QuikStation 4VRDX^^^^RMVBL_VDISKiSCSIdisk
RDX QuikStation 8VRDX^^^^RMVBL_VDISKiSCSIdisk
RDX QuikStor External USB3+TANDBERGRDXUSBdisk

OST-Appliance

OpenStorage Servers are intelligent storage devices that interface to Backup Exec Servers and Remote Agents for Windows (with Direct Access) via the Veritas OpenStorage (OST) API. The vendor supplying the Storage Server appliance provides a software Plug-in, which is installed on each Backup Exec Server and Remote Agent for Windows (with Direct Access) that is attached to the OpenStorage Server.

OST functionality is available on supported Windows Backup Exec 20 Backup Exec Server and Remote Agent for Windows platforms.

Please see the Backup Exec System Administrator's Guide for more information on how to use OST.

Attention: OpenStorage (OST) appliance users: Backup Exec 20 may require a new OST plug-in from your appliance vendor.
Please contact your vendor for access to this new plug-in. If needed, the required Backup Exec 20 plug-in details will be listed as a footnote in the "Storage Server Family" column, per vendor.

In the tables below, "Basic Duplication" refers to server-side or client-side deduplication.

Where support is shown for Windows Server 2008, Windows Server 2012, or Windows Server 2016, please reference the Software Compatibility List ( http://www.veritas.com/docs/000115689 ) for supported operating system versions.

Go to Top of "OST-Appliance"

Datish Systems (OpenDedup)

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2012Windows Server 2016Supported OpenStorage Functionality
SDFS Cloud File System [1][2][3][4]SDFS Cloud File System2.1EthernetBasic Deduplication, Optimized Duplication
  • f67-1
  • f67-2
  • f67-3
  • f67-4
  1. Note: OpenDedupe devices must NOT be shared between BE server nodes, even in an MMS/CAS environment. Do not use the same cloud bucket for two different BE servers. OpenDedupe does not support device sharing at this time. Although BE may allow you to share the device, you must not share it. Corruption of the dedupe data is a likely result.
  2. Plugin version 2.1.3.0 is required.
  3. SDFS Cloud File System 3.4.10.1 is required.
  4. The OpenDedupe OST Plugin is not supported on a Backup Exec Remote Agent. The Opendedupe OST plugin must be used on a Backup Exec Server.
Go to Top of "OST-Appliance"

Dell EMC

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Supported OpenStorage Functionality
DR Series [1][2][3][4]DR4000, DR4100, DR60003.2EthernetBasic Deduplication, Optimized Duplication
  • f68-1
  • f68-2
  • f68-3
  • f68-4
  1. Dell EMC has separated/sold the DR appliance division into Quest. Customers should migrate to running newer Quest branded software on the appliance and using the Quest branded plugin. Download Quest stuff from https://support.quest.com/download-product-select
  2. Please see the Quest section for new devices and newer software versions.
  3. The 3.2 PLUGINS work with BE 20, but the 3.2 INSTALLER does NOT work with BE 20.
  4. Please note: this device is nearing the end of support. Please see the 'Retiring Soon' section.
Go to Top of "OST-Appliance"

Dell EMC Data Domain

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Windows Server 2016Supported OpenStorage Functionality
Appliance series [1][2][3]DD140, DD160, DD510, DD530, DD560, DD565, DD580, DD610, DD620, DD630, DD640, DD660, DD670, DD690, DD860, DD880, DD890, DD990, DD2200, DD2500, DD3300, DD4200, DD4500, DD6300, DD6800, DD7200, DD9300, DD9500, DD98003.1EthernetBasic Deduplication, Optimized Duplication
  • f69-1
  • f69-2
  • f69-3
Appliance series [1][2]DD140, DD160, DD510, DD530, DD560, DD565, DD580, DD610, DD620, DD630, DD640, DD660, DD670, DD690, DD860, DD880, DD890, DD990, DD2200, DD2500, DD3300, DD4200, DD4500, DD6300, DD6800, DD7200, DD9300, DD9500, DD98003.2EthernetBasic Deduplication, Optimized Duplication
  • f69-1
  • f69-2
Appliance series [1][2]DD140, DD160, DD510, DD530, DD560, DD565, DD580, DD610, DD620, DD630, DD640, DD660, DD670, DD690, DD860, DD880, DD890, DD990, DD2200, DD2500, DD3300, DD4200, DD4500, DD6300, DD6800, DD7200, DD9300, DD9500, DD98003.3EthernetBasic Deduplication, Optimized Duplication
  • f69-1
  • f69-2
Appliance series [1][2]DD140, DD160, DD510, DD530, DD560, DD565, DD580, DD610, DD620, DD630, DD640, DD660, DD670, DD690, DD860, DD880, DD890, DD990, DD2200, DD2500, DD3300, DD4200, DD4500, DD6300, DD6800, DD7200, DD9300, DD9500, DD98003.4EthernetBasic Deduplication, Optimized Duplication
  • f69-1
  • f69-2
Appliance series [1][2]DD140, DD160, DD510, DD530, DD560, DD565, DD580, DD610, DD620, DD630, DD640, DD660, DD670, DD690, DD860, DD880, DD890, DD990, DD2200, DD2500, DD3300, DD4200, DD4500, DD6300, DD6800, DD7200, DD9300, DD9500, DD98003.5EthernetBasic Deduplication, Optimized Duplication
  • f69-1
  • f69-2
Virtual Edition (Hyper-V) [1]Virtual Edition (Hyper-V)3.3EthernetBasic Deduplication, Optimized Duplication
  • f69-1
Virtual Edition (Hyper-V) [1]Virtual Edition (Hyper-V)3.4EthernetBasic Deduplication, Optimized Duplication
  • f69-1
Virtual Edition (Hyper-V) [1]Virtual Edition (Hyper-V)3.5EthernetBasic Deduplication, Optimized Duplication
  • f69-1
Virtual Edition (VMware) [1][3]Virtual Edition (VMware)3.1EthernetBasic Deduplication, Optimized Duplication
  • f69-1
  • f69-3
Virtual Edition (VMware) [1]Virtual Edition (VMware)3.2EthernetBasic Deduplication, Optimized Duplication
  • f69-1
Virtual Edition (VMware) [1]Virtual Edition (VMware)3.3EthernetBasic Deduplication, Optimized Duplication
  • f69-1
Virtual Edition (VMware) [1]Virtual Edition (VMware)3.4EthernetBasic Deduplication, Optimized Duplication
  • f69-1
Virtual Edition (VMware) [1]Virtual Edition (VMware)3.5EthernetBasic Deduplication, Optimized Duplication
  • f69-1
  1. Plugin 3.3.1.2-562106 is the recommended minimum version for 3.3 plugins.
  2. See the Backup Exec sections in the DataDomain OST Admin guide for installation and configuration details. (Data Domain Support account and access to the 2.x plug-in release required)
  3. Please note: this device is nearing the end of support. Please see the 'Retiring Soon' section.
Go to Top of "OST-Appliance"

ExaGrid

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Windows Server 2016Supported OpenStorage Functionality
EX series [1][2][3][4]EX1000, EX2000, EX3000, EX4000, EX5000, EX7000, EX7000-SEC, EX10000E, EX10000E-SEC, EX13000E, EX13000E-SEC, EX21000E, EX21000E-SEC, EX32000E, EX32000E-SEC, EX40000E, EX40000E-SEC, EX63000E, EX63000E-SECV11.4.0EthernetBasic Deduplication, Optimized Duplication
  • f70-1
  • f70-2
  • f70-3
  • f70-4
  1. Browse to the Help->Online Library in the ExaGrid administrative interface and view/download Using Symantec Backup Exec™ with an ExaGrid System.
  2. ExaGrid OS version 4.6.4 P12 (or higher) is required.
  3. For more information, see here: http://www.exagrid.com/backup_applications/Symantec_VERITAS_Backup_Exec.asp
  4. Plug-in version V11.4.0.38.868 (or higher) is required for NEW Backup Exec 20 installations. Older (supported) versions of the plugin are acceptable when Backup Exec is upgraded in-place to Backup Exec 20.
Go to Top of "OST-Appliance"

FalconStor

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Supported OpenStorage Functionality
FDS series [1][2][3]FDS 100, FDS 300, FDS 6002.2EthernetBasic Deduplication, Optimized Duplication
  • f71-1
  • f71-2
  • f71-3
  1. FDS Server version 2.10 (or newer) is required for usage with BE 16.
  2. Please contact FalconStor for procedure and requirements for large chunk size (block size) support. The block size used for the FDS must match the selected "data stream chunk size" in the Advanced Property section for the OST storage device.
  3. The OpenStorage plug-in can be obtained through Falconstor Professional Services.
Go to Top of "OST-Appliance"

Fujitsu

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Windows Server 2016Supported OpenStorage Functionality
ETERNUS CS800 S4 [1][2]ETERNUS CS800 S43.0EthernetBasic Deduplication, Optimized Duplication
  • f72-1
  • f72-2
ETERNUS CS800 S4 [1][2]ETERNUS CS800 S43.1EthernetBasic Deduplication, Optimized Duplication
  • f72-1
  • f72-2
ETERNUS CS800 S4 [1][2]ETERNUS CS800 S410.0EthernetBasic Deduplication, Optimized Duplication
  • f72-1
  • f72-2
ETERNUS CS800 S5 [1][2]ETERNUS CS800 S53.0EthernetBasic Deduplication, Optimized Duplication
  • f72-1
  • f72-2
ETERNUS CS800 S5 [1][2]ETERNUS CS800 S53.1EthernetBasic Deduplication, Optimized Duplication
  • f72-1
  • f72-2
ETERNUS CS800 S5 [1][2]ETERNUS CS800 S510.0EthernetBasic Deduplication, Optimized Duplication
  • f72-1
  • f72-2
ETERNUS CS800 S6 [1][2]ETERNUS CS800 S63.0EthernetBasic Deduplication, Optimized Duplication
  • f72-1
  • f72-2
ETERNUS CS800 S6 [1][2]ETERNUS CS800 S63.1EthernetBasic Deduplication, Optimized Duplication
  • f72-1
  • f72-2
ETERNUS CS800 S6 [1][2]ETERNUS CS800 S610.0EthernetBasic Deduplication, Optimized Duplication
  • f72-1
  • f72-2
ETERNUS CS800 S7 [1]ETERNUS CS800 S710.0EthernetBasic Deduplication, Optimized Duplication
  • f72-1
  1. For more information, see http://support.ts.fujitsu.com/Download/ Then, fill in the following values in the "Driver and Downloads" section: select "Storage solutions", then select "ETERNUS CS/CentricStor", then select "ETERNUS CS800"
  2. Plug-in version 3.1.2 (or higher) is required for NEW Backup Exec 20 installations. Older (supported) versions of the plugin are acceptable when Backup Exec is upgraded in-place to Backup Exec 20.
Go to Top of "OST-Appliance"

H3C

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Supported OpenStorage Functionality
CP3310 [1]CP33102.0EthernetBasic Deduplication, Optimized Duplication
  • f73-1
CP3352 [1][2]CP33522.0EthernetBasic Deduplication, Optimized Duplication
  • f73-1
  • f73-2
CP3352 [2]CP33524.1Ethernet, Fibre ChannelBasic Deduplication, Optimized Duplication
  • f73-2
CP3354 [1][2]CP33542.0EthernetBasic Deduplication, Optimized Duplication
  • f73-1
  • f73-2
CP3354 [2]CP33544.1Fibre Channel, EthernetBasic Deduplication, Optimized Duplication
  • f73-2
CP5510 [1][2]CP55102.0EthernetBasic Deduplication, Optimized Duplication
  • f73-1
  • f73-2
CP5510 [2]CP55104.1Fibre Channel, EthernetBasic Deduplication, Optimized Duplication
  • f73-2
CP5550 [1][2]CP55502.0EthernetBasic Deduplication, Optimized Duplication
  • f73-1
  • f73-2
CP5550 [2]CP55504.1Fibre Channel, EthernetBasic Deduplication, Optimized Duplication
  • f73-2
CP6660 [1][2]CP66602.0EthernetBasic Deduplication, Optimized Duplication
  • f73-1
  • f73-2
CP6660 [2]CP66604.1Ethernet, Fibre ChannelBasic Deduplication, Optimized Duplication
  • f73-2
  1. Please note: this device is nearing the end of support. Please see the 'Retiring Soon' section.
  2. Refer to the following technote for FC configuration information. https://www.veritas.com/support/en_US/article.100041993
Go to Top of "OST-Appliance"

Hewlett Packard Enterprise

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Windows Server 2016Supported OpenStorage Functionality
StoreOnce 2000 series [1][2]StoreOnce 2610, StoreOnce 2620, StoreOnce 2700, StoreOnce 29002.0EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-2
StoreOnce 2000 series [1]StoreOnce 2610, StoreOnce 2620, StoreOnce 2700, StoreOnce 29004.1EthernetBasic Deduplication, Optimized Duplication
  • f74-1
StoreOnce 2000 series [1]StoreOnce 2610, StoreOnce 2620, StoreOnce 2700, StoreOnce 29004.2EthernetBasic Deduplication, Optimized Duplication
  • f74-1
StoreOnce 3000 series [1][2][3]StoreOnce 31002.0EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-2
  • f74-3
StoreOnce 3000 series [1][3]StoreOnce 31004.1EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-3
StoreOnce 3000 series [1][3]StoreOnce 31004.2EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-3
StoreOnce 3500/3600 series [1][2][3][4][5]StoreOnce 3520, StoreOnce 3540, StoreOnce 3620, StoreOnce 36402.0EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-2
  • f74-3
  • f74-4
  • f74-5
StoreOnce 3500/3600 series [1][3][4][5]StoreOnce 3520, StoreOnce 3540, StoreOnce 3620, StoreOnce 36404.1Ethernet, Fibre ChannelBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-3
  • f74-4
  • f74-5
StoreOnce 3500/3600 series [1][3][4][5]StoreOnce 3520, StoreOnce 3540, StoreOnce 3620, StoreOnce 36404.2Fibre Channel, EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-3
  • f74-4
  • f74-5
StoreOnce 4000 series [1][2][4][5]StoreOnce 4210fc, StoreOnce 4210i, StoreOnce 4220, StoreOnce 4420, StoreOnce 4430, StoreOnce 4500, StoreOnce 4700, StoreOnce 49002.0EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-2
  • f74-4
  • f74-5
StoreOnce 4000 series [1][4][5]StoreOnce 4210fc, StoreOnce 4210i, StoreOnce 4220, StoreOnce 4420, StoreOnce 4430, StoreOnce 4500, StoreOnce 4700, StoreOnce 49004.1Fibre Channel, EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-4
  • f74-5
StoreOnce 4000 series [1][4][5]StoreOnce 4210fc, StoreOnce 4210i, StoreOnce 4220, StoreOnce 4420, StoreOnce 4430, StoreOnce 4500, StoreOnce 4700, StoreOnce 49004.2Ethernet, Fibre ChannelBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-4
  • f74-5
StoreOnce 5000 series [1][2][3][4][5]StoreOnce 5100, StoreOnce 5200, StoreOnce 5250, StoreOnce 5500, StoreOnce 56502.0EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-2
  • f74-3
  • f74-4
  • f74-5
StoreOnce 5000 series [1][3][4][5]StoreOnce 5100, StoreOnce 5200, StoreOnce 5250, StoreOnce 5500, StoreOnce 56504.1Ethernet, Fibre ChannelBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-3
  • f74-4
  • f74-5
StoreOnce 5000 series [1][3][4][5]StoreOnce 5100, StoreOnce 5200, StoreOnce 5250, StoreOnce 5500, StoreOnce 56504.2Ethernet, Fibre ChannelBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-3
  • f74-4
  • f74-5
StoreOnce 6000 series [1][2][4][5]StoreOnce 6500, StoreOnce 6600, StoreOnce B62002.0EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-2
  • f74-4
  • f74-5
StoreOnce 6000 series [1][4][5]StoreOnce 6500, StoreOnce 6600, StoreOnce B62004.1Fibre Channel, EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-4
  • f74-5
StoreOnce 6000 series [1][4][5]StoreOnce 6500, StoreOnce 6600, StoreOnce B62004.2Ethernet, Fibre ChannelBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-4
  • f74-5
StoreOnce VSA (Hyper-V) [1][2][5][6]StoreOnce VSA (Hyper-V)2.0EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-2
  • f74-5
  • f74-6
StoreOnce VSA (Hyper-V) [1][5][6]StoreOnce VSA (Hyper-V)4.1EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-5
  • f74-6
StoreOnce VSA (Hyper-V) [1][5][6]StoreOnce VSA (Hyper-V)4.2EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-5
  • f74-6
StoreOnce VSA (VMware) [1][2][5][6]StoreOnce VSA (VMware)2.0EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-2
  • f74-5
  • f74-6
StoreOnce VSA (VMware) [1][5][6]StoreOnce VSA (VMware)4.1EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-5
  • f74-6
StoreOnce VSA (VMware) [1][5][6]StoreOnce VSA (VMware)4.2EthernetBasic Deduplication, Optimized Duplication
  • f74-1
  • f74-5
  • f74-6
  1. The HPE v4.1 and v4.2 OST plugins do not support client-side deduplication for systems running the Backup Exec remote agent. This will be addressed by HPE in a future release of the plugin. For now, deduplication from the remote system must be done via server-side.
  2. Please note: this device is nearing the end of support. Please see the 'Retiring Soon' section.
  3. Version 3.14 code is the minimum required for the StoreOnce 3100, 3520, 3540, 5100, or 5500 devices. The code is not backwards compatible with earlier versions of StoreOnce hardware. For more information, please contact Hewlett Packard Enterprise.
  4. Refer to the following technote for FC configuration information. https://www.veritas.com/support/en_US/article.100041993
  5. There is a capacity reporting issue with early versions of the 4.2 plugin. Please upgrade to 4.2.1.2532 (or greater) or consult HPE about bugs 123275 & 124555
  6. StoreOnce VSA is a virtual appliance. For device details and platform support refer to: https://www.hpe.com/h20195/v2/GetDocument.aspx?docname=c04328820
Go to Top of "OST-Appliance"

Quantum

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Windows Server 2016Supported OpenStorage Functionality
DXi4000 Series [1][2][3][4]DXi4510, DXi4520, DXi46013.1EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi4000 Series [1][2][3][4]DXi4510, DXi4520, DXi460110.0EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi4700 Series [1][2][3][4]DXi47013.1EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi4700 Series [1][2][3][4]DXi470110.0EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi4800 Series [1][2][3][4]DXi480010.0EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi6000 Series [1][2][3][4]DXi6510, DXi6520, DXi6530, DXi6540, DXi65503.1EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi6000 Series [1][2][3][4]DXi6510, DXi6520, DXi6530, DXi6540, DXi655010.0EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi6700 Series [1][2][3][4]DXi6700, DXi6701, DXi67023.1EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi6700 Series [1][2][3][4]DXi6700, DXi6701, DXi670210.0EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi6800 Series [1][2][3][4]DXi68023.1EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi6800 Series [1][2][3][4]DXi680210.0EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi6900 Series [1][2][3][4]DXi6900, DXi6900-S3.1EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi6900 Series [1][2][3][4]DXi6900, DXi6900-S10.0EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi7500 Series [1][2][3][4]DXi7500 Enterprise, DXi7500 Express, DXi7500-N3.1EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi7500 Series [1][2][3][4]DXi7500 Enterprise, DXi7500 Express, DXi7500-N10.0EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi8500 Series [1][2][3][4]DXi8500, DXi8500 2TB, DXi8500 3TB3.1EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi8500 Series [1][2][3][4]DXi8500, DXi8500 2TB, DXi8500 3TB10.0EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi9000 Series [1][2][3][4]DXi900010.0EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
DXi V Series [1][2][3][4][5]DXi V1000, DXi V2000, DXi V40003.1EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
  • f75-5
DXi V Series [1][2][3][4][5]DXi V1000, DXi V2000, DXi V400010.0EthernetBasic Deduplication, Optimized Duplication
  • f75-1
  • f75-2
  • f75-3
  • f75-4
  • f75-5
  1. For more information, see http://www.quantum.com/ServiceandSupport/SoftwareandDocumentationDownloads/OSTClientPlugIn/Index.aspx
  2. Plug-in version 3.1.2 (or higher) is required for NEW Backup Exec 20 installations. Older (supported) versions of the plugin are acceptable when Backup Exec is upgraded in-place to Backup Exec 20. Plug-in version 3.1.2 is officially supported.
  3. Quantum DXi OST plugins, version 10.0.0 and above, support 64 bit systems only.
  4. The Quantum hostname and storage server name needs to be different to avoid connection issues.
  5. This device is a virtual appliance. Representative VMware-supported ESX4, ESXi4, or ESXi5 servers/storage were tested. Refer to http://downloads.quantum.com/dxiv1000/6-67611-01_DXi_V1000_QuickStartGuide_RevA.pdf
Go to Top of "OST-Appliance"

Quest

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Windows Server 2016Windows Server 2019Supported OpenStorage Functionality
DR 11g Series [1][2][3][4][5]DR40003.2EthernetBasic Deduplication, Optimized Duplication
  • f76-1
  • f76-2
  • f76-3
  • f76-4
  • f76-5
DR 11g Series [1][2][3][4][5]DR40004.0EthernetBasic Deduplication, Optimized Duplication
  • f76-1
  • f76-2
  • f76-3
  • f76-4
  • f76-5
DR 12g Series [1][2][3][4][5]DR4100, DR60003.2EthernetBasic Deduplication, Optimized Duplication
  • f76-1
  • f76-2
  • f76-3
  • f76-4
  • f76-5
DR 12g Series [1][2][3][4][5]DR4100, DR60004.0EthernetBasic Deduplication, Optimized Duplication
  • f76-1
  • f76-2
  • f76-3
  • f76-4
  • f76-5
DR 13g Series [1][2][3][4][5]DR4300, DR4300e, DR63003.2EthernetBasic Deduplication, Optimized Duplication
  • f76-1
  • f76-2
  • f76-3
  • f76-4
  • f76-5
DR 13g Series [1][2][3][4][5]DR4300, DR4300e, DR63004.0EthernetBasic Deduplication, Optimized Duplication
  • f76-1
  • f76-2
  • f76-3
  • f76-4
  • f76-5
QoreStor [6][7]QoreStor4.1EthernetBasic Deduplication, Optimized Duplication
  • f76-6
  • f76-7
  1. Dell EMC has separated/sold the DR appliance division into Quest. Customers should migrate to running newer Quest branded software on the appliance and using the Quest branded plugin. Download Quest stuff from https://support.quest.com/download-product-select
  2. For 4.0: The Quest packaged 4.x plug-in installer should be used to install the required OST plugin. The Quest packaged 4.0.2 (or newer) plug-in installer now installs two plugin files, one named for Dell and one named for Quest. When configuring storage within Backup Exec 20, and if your DR appliance is running 4.0.2 (or newer), please select the "Quest" provider. The Backup Exec adamm.log will document which plugin is being used in the line “OST Server: DELL:DR4300-HPVxxxx” versus “OST Server: QUEST:DR4300-HPVxxxx”. There are no performance differences between the different named plugins. There are no changes to the container on the Quest DR appliance side. The container may be using either the Symantec or the Veritas OST access protocol. In other words: The Dell-named libstspiDellMT.dll works & is supported by Backup Exec 20. The preferred Quest-named libstspiocaMT.dll works & is supported in Backup Exec 20.
  3. Please see the Quest Migration Guide https://support.quest.com/download/downloads?id=6084223
  4. Plug-in version 4.0.3049 (or higher) is required for NEW Backup Exec 20 installations. Older (supported) versions of the plugin (3.2 & 4.0) are acceptable when Backup Exec is upgraded in-place to Backup Exec 20.
  5. The 3.2 PLUGINS work with BE 20, but the 3.2 INSTALLER does NOT work with BE 20.
  6. QoreStor is supported on Linux, ESX & Hyper-V platforms.
  7. The Quest packaged 4.x plug-in installer should be used to install the required OST plugin. The Quest packaged 4.0.2 (or newer) plug-in installer now installs two plugin files, one named for Dell and one named for Quest. When configuring storage within Backup Exec 20, please select the "Quest" provider. The Backup Exec adamm.log will document which plugin is being used in the line “OST Server: DELL:hostname:container” versus “OST Server: QUEST:hostname:container”. There are no performance differences between the different named plugins. There are no changes to the container on the Quest QoreStor side. The container may be using either the Symantec or the Veritas OST access protocol. In other words: The Dell-named libstspiDellMT.dll works & is supported by Backup Exec 20. The preferred Quest-named libstspiocaMT.dll works & is supported in Backup Exec 20.
Go to Top of "OST-Appliance"

Veritas

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Supported OpenStorage Functionality
NetBackup 5000 [1][2][3][4]NetBackup 50006.6.5EthernetBasic Deduplication, Optimized Duplication
  • f77-1
  • f77-2
  • f77-3
  • f77-4
NetBackup 5020 [1][2][3][4]NetBackup 50206.6.5EthernetBasic Deduplication, Optimized Duplication
  • f77-1
  • f77-2
  • f77-3
  • f77-4
NetBackup 5030 [1][2][4]NetBackup 50306.6.5EthernetBasic Deduplication, Optimized Duplication
  • f77-1
  • f77-2
  • f77-4
  1. BE 2012 introduced optimized duplication (opt-dupe) operations for GRT backup sets. If a NetBackup 50x0 is specified as the source of a GRT opt-dupe, the operation will fall back to the previous BE 2010 behavior of rehydrating all of the data from the NetBackup 50x0 to the media server before transmitting only the unique data to the target server.
  2. If a NetBackup 50x0 is specified as the source of an optimized duplication (opt-dupe) operation, only 1 opt-dupe on that media server will execute at a time. Other opt-dupe, backup, verify, and restore operations will be blocked from running until that opt-dupe job finishes.
  3. NBU 5000/5020 software versions v1.4.3.1, or newer, are strongly recommended.
  4. The required plug-in for this appliance is included with Backup Exec. When adding the NBU 50x0 OpenStorage device, select the "PureDisk" option. Note: the PureDisk installation log-on screen references plug-ins. These are not needed since Backup Exec includes the plug-in natively.

VSS Providers for Offhost backup

This list of tested Volume Shadow Copy Service (VSS) components represents what has been tested in Veritas labs, or in Veritas-supervised partner labs. To ensure compatibility, Veritas, the device manufacturers, and the operating system vendor must support the combination of VSS components. Note: The Backup Exec Advanced Disk Based Backup Option, now part of the Enterprise Server Option, is required for VSS. See the Administrator's Guide for more details on usage of the VSS provider.

Please Note:

1. The provider version and array firmware listed in this section are the minimum levels that are supported. Where more than one entry level is listed in these "Minimum" columns, this implies a newer version has been tested. The earlier versions are the minimum versions required. The hardware vendor may specify rules for pairing of the provider and firmware versions.

2. The Array Firmware listed in this section are the minimum levels that are supported.

3. The Advanced Open File job options are not supported for use with Dynamic Disk Snapshots.

Go to Top of "VSS Providers for Offhost backup"

Dell EMC

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
CLARiiON CX3 seriesCLARiiON CX3 Model 10, CLARiiON CX3 Model 20, CLARiiON CX3 Model 40, CLARiiON CX3 Model 80Fibre ChannelFLARE 26Solutions Enabler with VSS Provider4.0.1
CLARiiON CX4 series [1]CLARiiON CX4 Model 120, CLARiiON CX4 Model 240, CLARiiON CX4 Model 480, CLARiiON CX4 Model 960Fibre ChannelFLARE 28Solutions Enabler with VSS Provider4.1.2
  • f78-1
CLARiiON CX series [2]CLARiiON CX300, CLARiiON CX400, CLARiiON CX500, CLARiiON CX600, CLARiiON CX700Fibre Channel02.19.500.5.016CLARiiON VSS Provider1.5.0.3.8
  • f78-2
CLARiiON CX series [2]CLARiiON CX300, CLARiiON CX400, CLARiiON CX500, CLARiiON CX600, CLARiiON CX700Fibre ChannelFLARE 26Solutions Enabler with VSS Provider4.0.1
  • f78-2
Compellent Storage Center 5Compellent Storage Center 5.2, Compellent Storage Center 5.3, Compellent Storage Center 5.4Fibre Channel, iSCSI5.4.3Replay Manager VSS Provider06.00.02.002,
06.01.00.010
Compellent Storage Center 6.5Compellent Storage Center 6.5Fibre Channel, iSCSI6.5.10Replay Manager VSS Provider07.00.00.008
EqualLogic PS3000 seriesEqualLogic PS3000E, EqualLogic PS3000X, EqualLogic PS3000XViSCSIV4.3.0 (R104535)VSS Provider3.3.0.4883
EqualLogic PS4000 seriesEqualLogic PS4000E, EqualLogic PS4000X, EqualLogic PS4000XV, EqualLogic PS4100E, EqualLogic PS4100X, EqualLogic PS4100XV, EqualLogic PS4100XV3.5"iSCSIV4.3.0 (R104535)VSS Provider3.3.0.4883
EqualLogic PS5000 seriesEqualLogic PS5000E, EqualLogic PS5000X, EqualLogic PS5000XV, EqualLogic PS5500EiSCSIV4.3.0 (R104535)VSS Provider3.3.0.4883
EqualLogic PS6000 seriesEqualLogic PS6000E, EqualLogic PS6000S, EqualLogic PS6000X, EqualLogic PS6000XV, EqualLogic PS6000XVS, EqualLogic PS6010E, EqualLogic PS6010S, EqualLogic PS6010X, EqualLogic PS6010XV, EqualLogic PS6010XVS, EqualLogic PS6100E, EqualLogic PS6100X, EqualLogic PS6100XV, EqualLogic PS6100XV3.5", EqualLogic PS6500E, EqualLogic PS6500X, EqualLogic PS6500XV, EqualLogic PS6510E, EqualLogic PS6510X, EqualLogic PX6100S, EqualLogic PX6100XSiSCSIV4.3.0 (R104535)VSS Provider3.3.0.4883
EqualLogic PS series [1]EqualLogic PS100EiSCSIV2.2.3 (R75),
V4.0.2 (R83937)
VSS Provider2.0.0.0,
2.2.1,
3.0,
3.1.2.0
  • f78-1
PowerVault MD30xx Series [1][3]PowerVault MD3000, PowerVault MD3000iiSCSI, SAS06.17.77.60,
7.35.00.00,
06.70.10.60
VSS Provider SmVssProvider09.17.05,
10.70.08,
09.70.02
  • f78-1
  • f78-3
PowerVault MD32xx Series [1]PowerVault MD3200, PowerVault MD3200i, PowerVault MD3220, PowerVault MD3220iiSCSI, SAS7.70.00.00VSS Provider SmVssProvider10.70.08
  • f78-1
  1. Only basic disks are supported, per the VSS provider.
  2. For the older provider (CLARiiON VSS Provider), only Snapshots are supported. Clones are not supported. The newer provider (Solutions Enabler with VSS Provider) does not have this limitation.
  3. The MD3000/MD3000i does not support concurrent multi-volume snapshot (includes Mount Points).
Go to Top of "VSS Providers for Offhost backup"

Fujitsu

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
ETERNUS4000 series [1]ETERNUS4000 Model 80, ETERNUS4000 Model 100, ETERNUS4000 Model 300, ETERNUS4000 Model 400, ETERNUS4000 Model 500, ETERNUS4000 Model 600Fibre ChannelV20L21-0000Eternus VSS Hardware Provider1.3.0
  • f79-1
ETERNUS8000 series [1]ETERNUS8000 Model 700, ETERNUS8000 Model 800, ETERNUS8000 Model 900, ETERNUS8000 Model 1100, ETERNUS8000 Model 1200, ETERNUS8000 Model 2100, ETERNUS8000 Model 2200Fibre ChannelN/AEternus VSS Hardware Provider1.3.0
  • f79-1
ETERNUS DX60/DX80/DX90 series [1][2][3]ETERNUS AF250 S2, ETERNUS DX60, ETERNUS DX60 S2, ETERNUS DX60 S3, ETERNUS DX80, ETERNUS DX80 S2, ETERNUS DX90, ETERNUS DX90 S2Fibre Channel, iSCSIN/A,
V10L22-3000
Eternus VSS Hardware Provider1.3.0,
2.1.0
  • f79-1
  • f79-2
  • f79-3
ETERNUS DX400 series [1][2]ETERNUS AF650 S2, ETERNUS DX410, ETERNUS DX410 S2, ETERNUS DX440, ETERNUS DX440 S2, ETERNUS DX500 S4, ETERNUS DX600 S4iSCSIN/AEternus VSS Hardware Provider2.1.0
  • f79-1
  • f79-2
ETERNUS DX8000 series [1][2]ETERNUS DX8100, ETERNUS DX8100 S2, ETERNUS DX8400, ETERNUS DX8700, ETERNUS DX8700 S2iSCSIN/AEternus VSS Hardware Provider2.1.0
  • f79-1
  • f79-2
  1. Only basic disks are supported, per the VSS provider.
  2. Series S2 platforms require a v2.x provider.
  3. The ETERNUS DX60 S2 requires a v1.x provider.
Go to Top of "VSS Providers for Offhost backup"

Hewlett Packard Enterprise

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
2000 G2 seriesMSA2312fc, MSA2312i, MSA2312sa, MSA2324fc, MSA2324i, MSA2324saFibre Channel, iSCSI, SASM110R21P2000/MSA2000 VSS Provider2.7.0.0
EVA4000/6000/8000EVA4000, EVA6000, EVA8000Fibre ChannelXCS 5.031EVA VSS Provider3.0.6
EVA4100/6100/8100EVA4100, EVA6100, EVA8100Fibre Channel, iSCSIXCS 5.031EVA VSS Provider3.0.6
EVA4400/6400/8400 series [1][2]EVA4400, EVA6400, EVA8400Fibre Channel, iSCSIXCS 9.5011,
XCS 9.5012
EVA VSS Provider4.03.00.02,
5.01.00.02
  • f80-1
  • f80-2
LeftHand P4000 Virtual San ApplianceLeftHand P4300, LeftHand P4500iSCSI8.1.00.0047.0SAN/iQ Solutions Pack8.1.00.0047.0
P2000 G3 MSA seriesP2000 G3 FC, P2000 G3 FC/iSCSI, P2000 G3 iSCSI, P2000 G3 SASFibre Channel, iSCSI, SASTS200R021P2000/MSA2000 VSS Provider2.7.0.0
  1. Only basic disks are supported, per the VSS provider.
  2. The minimum VSS provider for Windows 2008 is 5.01.00.02.
Go to Top of "VSS Providers for Offhost backup"

Hitachi

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
AMS/WMS seriesAMS200, AMS500, AMS1000, WMS100Fibre Channel, iSCSI0772/D-SShadow Copy Provider Softwarev3.0.0.0
AMS/WMS seriesAMS200, AMS500, AMS1000, WMS100Fibre Channel0893/E-XVSS Hardware Provider4.3.5
BR1200 [1]BR1200Fibre Channel, iSCSI, SAS7.77.19.00VSS Provider SmVssProvider10.77.30
  • f81-1
Lightning 9900V series9970V, 9980Fibre Channel21-09-15-00/00RM ShadowCopy Provider01-02-03/01
SMS/AMS2000 series [1]AMS2100, AMS2300, AMS2500, SMS100Fibre Channel, iSCSI0843/B-SRM ShadowCopy Provider01.01.0003.0000
  • f81-1
SMS/AMS2000 series [1]AMS2100, AMS2300, AMS2500, SMS100Fibre Channel, iSCSI1811/A-A,
0843/B-S
Shadow Copy Provider Softwarev3.0.0.0,
v3.2.0
  • f81-1
SMS/AMS2000 series [1]AMS2100, AMS2300, AMS2500, SMS1000893/E-XVSS Hardware Provider4.3.5
  • f81-1
  1. Only basic disks are supported, per the VSS provider.
Go to Top of "VSS Providers for Offhost backup"

IBM

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
DS3950 [1]DS3950Fibre Channel, iSCSI7.70.00.00VSS Provider SmVssProvider10.70.08
  • f82-1
DS5020 [1]DS5020Fibre Channel7.70.00.00VSS Provider SmVssProvider10.70.08
  • f82-1
System Storage DS3000 series [1]DS3200, DS3300, DS3400Fibre Channel, iSCSI, SAS07.35.42,
7.35.00.00
VSS Provider SmVssProvider09.70.06,
10.70.08
  • f82-1
System Storage DS3500 series [1]DCS3700, DS3512, DS3524Fibre Channel, iSCSI, SAS7.70.00.00VSS Provider SmVssProvider10.70.08
  • f82-1
System Storage DS5000 series [1]DS5100, DS5300Fibre Channel, iSCSI7.70.00.00VSS Provider SmVssProvider10.70.08
  • f82-1
System Storage DS6000 series [2]DS6000 (1750-511), DS6800Fibre Channel5.0.6.0041TotalStorage Hardware Provider for VSS2.4.2.0116
  • f82-2
System Storage DS8000 series [2]DS8000, DS8100, DS8300, DS8700, DS8800, DS8870, DS8880Fibre Channel5.1TotalStorage Hardware Provider for VSS3.2.1.0319
  • f82-2
TotalStorage DS4000 series [1][3]DS4100 (FAStT100), DS4200, DS4300 (FAStT600), DS4400 (FAStT700), DS4500 (FAStT900), DS4700, DS4800Fibre Channel04.10.22.00,
7.60.40.00,
6.60.00.00,
7.60.00.00,
6.12.00.00
VSS Provider SmVssProvider09.70.06,
10.70.08
  • f82-1
  • f82-3
  1. Only basic disks are supported, per the VSS provider.
  2. Only Snapshots are supported. Clones are not currently supported.
  3. In order to use the ADBO VSS feature, the IBM "Flash Copy" Premium Feature must be purchased.
Go to Top of "VSS Providers for Offhost backup"

Imation

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
Nexsan E-Series SystemsNexsan E18, Nexsan E48, Nexsan E60Fibre Channel, iSCSIQ011.1101.7VSS Hardware Provider1.6.33
Nexsan E-Series V SystemsNexsan E18V System, Nexsan E32V System, Nexsan E48V System, Nexsan E60V SystemFibre Channel, iSCSIR011.1201.3VSS Hardware Provider1.6.33
Nexsan NST2000Nexsan NST2000iSCSIN/AVSS Hardware Provider1.1.0
Nexsan NST4000Nexsan NST4000iSCSIN/AVSS Hardware Provider1.1.0
Nexsan NST5000Nexsan NST5000iSCSIN/AVSS Hardware Provider1.1.0
Nexsan NST6000Nexsan NST6000iSCSI3.1.2.55157VSS Hardware Provider1.1.0
Go to Top of "VSS Providers for Offhost backup"

LeftHand Networks

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
NSM 150NSM 150iSCSI6.6.00.0099.0SAN/iQ Solutions Pack1.3.0.44
Go to Top of "VSS Providers for Offhost backup"

LSI Logic

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
Engenio 1932 [1]Engenio 1932Fibre Channel07.35.42.00VSS Provider SmVssProvider09.70.06,
10.70.08
  • f85-1
  1. Only basic disks are supported, per the VSS provider.
Go to Top of "VSS Providers for Offhost backup"

NEC

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
iStorage S2000 series [1]iStorage S2100, iStorage S2300, iStorage S2400, iStorage S2500, iStorage S2800, iStorage S2900Fibre Channel010AStorage VSS Provider - iStorage S/A Series1.1.1.3
  • f86-1
  1. Only Replication Control (full copy method) is supported.
Go to Top of "VSS Providers for Offhost backup"

Oracle

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
Storage 6580/6780 series [1]Sun Storage 6580 array, Sun Storage 6780 arrayFibre Channel7.70.00.00VSS Provider SmVssProvider10.70.08
  • f87-1
StorageTek 2500 series [1]StorageTek 2510 array, StorageTek 2530 array, StorageTek 2540 array, Sun Storage 2530-M2 array, Sun Storage 2540-M2 arrayFibre Channel, iSCSI, SAS6.70.54.11,
7.35.00.00
VSS Provider SmVssProvider09.70.06,
10.70.08
  • f87-1
StorageTek 6140 array [1][2]StorageTek 6140 arrayFibre Channel07.10.22.00,
7.60.00.00
VSS Provider SmVssProvider09.70.06,
10.70.08
  • f87-1
  • f87-2
Sun Storage 6180 array [1]Sun Storage 6180 arrayFibre Channel7.70.00.00VSS Provider SmVssProvider10.70.08
  • f87-1
  1. Only basic disks are supported, per the VSS provider.
  2. Requires Sun 'Data Snapshot' Software
Go to Top of "VSS Providers for Offhost backup"

SGI

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
InfiniteStorage 350 [1][2]InfiniteStorage 350Fibre Channel04.10.22.00,
7.60.00.00
VSS Provider SmVssProvider09.70.06,
10.70.08
  • f88-1
  • f88-2
InfiniteStorage 4000 [1][2]InfiniteStorage 4000Fibre Channel04.10.22.00,
7.60.00.00
VSS Provider SmVssProvider09.70.06,
10.70.08
  • f88-1
  • f88-2
InfiniteStorage 4500 [2]InfiniteStorage 4500Fibre Channel04.10.22.00VSS Provider SmVssProvider09.70.06
  • f88-2
TP9500 [1]TP9500Fibre Channel6.60.00.00VSS Provider SmVssProvider10.70.08
  • f88-1
  1. Only basic disks are supported, per the VSS provider.
  2. Requires SGI 'SnapCopy' Software
Go to Top of "VSS Providers for Offhost backup"

StorageTek

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
FlexLine 200/300 series [1]FlexLine FLX280, FlexLine FLX380Fibre Channel6.60.00.00VSS Provider SmVssProvider10.70.08
  • f89-1
OPENstorage 9176/9170 [1]OPENstorage 9176/9170Fibre Channel6.12.00.00VSS Provider SmVssProvider10.70.08
  • f89-1
  1. Only basic disks are supported, per the VSS provider.
Go to Top of "VSS Providers for Offhost backup"

Sun

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
StorageTek 6130 [1][2]StorageTek 6130Fibre Channel07.10.22.00,
6.60.00.00
VSS Provider SmVssProvider09.70.06,
10.70.08
  • f90-1
  • f90-2
StorageTek 6540 [1][2]StorageTek 6540Fibre Channel07.10.22.00,
7.60.00.00
VSS Provider SmVssProvider09.70.06,
10.70.08
  • f90-1
  • f90-2
StorageTek 9176 [2]StorageTek 9176Fibre Channel07.10.22.00VSS Provider SmVssProvider09.70.06
  • f90-2
  1. Only basic disks are supported, per the VSS provider.
  2. Requires Sun 'Data Snapshot' Software
Go to Top of "VSS Providers for Offhost backup"

Xiotech

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
Magnitude 3DMagnitude 3DFibre Channel0503DataScale SP VSS HW Provider4.1.0.44
Go to Top of "VSS Providers for Offhost backup"

Xyratex

Device FamilyDevice Family MembersInterfaceMinimum Array FirmwareProvider NameMinimum Provider Version
RS-1220RS-1220Fibre ChannelN/AVSS Hardware Provider0.0.1.01

Virtual Tape Libraries with Drives

The virtual tape device support information is listed below. This information is organized by vendor and provides information on the level of software tested, inquiry string (vendor ID + product ID), and any other important notes about the hardware and its compatibility.

Please Note:

1. The virtual tape device software listed in this section are the minimum software levels that are supported. Where more than one software level is listed, this implies a newer version has been tested. The earlier software version is the minimum version required.

2. Configure the virtual device with the unique inquiry string as listed in this document. Emulating other devices is not supported.

3. For each virtual library only the virtual tape drives that are listed are supported. This information can be found with each virtual section. Other virtual tape drive types are not supported even if the real device is supported with Backup Exec.

4. Do not fill up the disk space on a virtual device. Doing so may cause unpredictable behavior of the device. The device vendor will then have to recover from any errors that result from a full disk.

5. When moving virtual volumes to physical media it works best if the virtual device has a volume size that is dynamic. Make sure that the virtual volume is slightly smaller than the physical volume. When you migrate the data to physical media you will need to ensure that there is enough space on the physical device in order to accommodate the virtual volume size.

6. It is highly recommended that Backup Exec move virtual volumes to physical media so that the data can be restored directly from physical media rather than needing to utilize the virtual device as an intermediary restoration point. If the virtual tape library moves virtual volumes to physical media Backup Exec is not aware of the physical media and may not be able to recover that data directly from that physical media.

7. When a virtual volume becomes overwriteable, the virtual device is not aware that the data is no longer needed. When Backup Exec overwrites that virtual volume the virtual library is aware that the rest of the data is not needed and it can free up the disk space. Because of this, the virtual device may appear to be much closer to capacity than it really is.

8. Tested iSCSI versions of virtual tape libraries are listed in the "iSCSI Solutions" section, under the "SAN Infrastructure components" bookmark. Please reference the limitations listed in that section.

9. The software versions documented here are obtained from the library interface (web or physical) and may not match the firmware version logged in the adamm.log.

10. All VTLs shared with the Linux server(s) must be approved for both RMAL and ESO. Zoning or LUN masking are possible methods of preventing Linux servers from seeing a VTL not approved for RMAL.

Go to Top of "Virtual Tape Libraries with Drives"

Virtual Tape Library/Drive Legend

ValueMeaning
^Character used to denote a space in the INQUIRY STRING.
Character used to denote support for the item listed in the column.
WinBESThe listed device is supported in a Windows Backup Exec Server platform. Shareability is determined by the ESO column. See the SCL ( http://www.veritas.com/docs/000115689 ) for supported Backup Exec Server Operating System platforms.
RMALThe listed device is supported in a Remote Media Agent for Linux platform. Shareability is determined by the ESO column. See the SCL ( http://www.veritas.com/docs/000115689 ) for supported Remote Media Agent for Linux platforms.
NDMPThe listed device is supported for use with NDMP. See the "NDMP Option" section for platform specific details. Shareability is determined by the ESO column.
ESOThe listed device is supported by the Enterprise Server Option using Fibre Channel. ESO refers to WinBES, and optionally RMAL or NDMP.
Go to Top of "Virtual Tape Libraries with Drives"

Dell EMC

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
CDL300 Series (members)Fibre ChannelIBMTotalStorage 3580 Ultrium 1EMC^^^^^Disk^Library
IBM^^^^^ULT3580-TD1
Disk Library Series (members)2.1.5 build 1175Fibre ChannelIBMTotalStorage 3580 Ultrium 1EMC^^^^^Disk^Library
IBM^^^^^ULT3580-TD1
Disk Library Series (members)2.1.5 build 1175Fibre ChannelIBMUltrium 2EMC^^^^^Disk^Library
IBM^^^^^ULTRIUM-TD2
NDMP2D5.5NDMPDell EMCEMC DLTEMC^^^^^svtlrobot
EMC^^^^^svtlDrive
Go to Top of "Virtual Tape Libraries with Drives"

Dell EMC Data Domain

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
Appliance Series (members)5.3Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3D_DOMAINRESTORER_L180
HP^^^^^^Ultrium^3-SCSI
Appliance Series (members)5.3Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4D_DOMAINRESTORER_L180
HP^^^^^^Ultrium^4-SCSI
Appliance Series (members) [1]5.5Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5D_DOMAINRESTORER_L180
HP^^^^^^Ultrium^5-SCSI
  • f95-1
Appliance Series (members)4.5.1.2Fibre ChannelIBMUltrium 1D_DOMAINRESTORER_L180
IBM^^^^^ULTRIUM-TD1
Appliance Series (members)5.3Fibre ChannelIBMUltrium 4D_DOMAINRESTORER_L180
IBM^^^^^ULTRIUM-TD4
DD400 Series (members) [2]4.1.5.0Fibre ChannelIBMUltrium 1D_DOMAINRESTORER_L180
IBM^^^^^ULTRIUM-TD1
  • f95-2
  1. Both the "D_DOMAINRESTORER_L180" and "EMC^^^^^DDVTL" library inquiry strings are supported when using DDOS 5.5 (or higher).
  2. VTLs are not shareable between servers. Each VTL must be configured with LUN masking so that it can only be seen by 1 server to prevent interference.
Go to Top of "Virtual Tape Libraries with Drives"

FalconStor

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
VirtualTape Library (RedHat 5.3 VTL Server Platform)5.20Fibre ChannelIBMUltrium 3FALCON^^VTL
IBM^^^^^ULTRIUM-TD3
VirtualTape Library (RedHat 5.3 VTL Server Platform)5.21Fibre ChannelIBMUltrium 4FALCON^^VTL
IBM^^^^^ULTRIUM-TD4
VirtualTape Library (RedHat AS Linux VTL Server Platform)3.00.1047 EEFibre ChannelIBMUltrium 1FALCON^^VTL
IBM^^^^^ULTRIUM-TD1
Go to Top of "Virtual Tape Libraries with Drives"

Fujitsu

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
ETERNUS CS (members) [1][2]4.1A4040-SP00-P130Fibre ChannelIBMUltrium 2FSC^^^^^CS-TL
IBM^^^^^ULTRIUM-TD2
  • f97-1
  • f97-2
ETERNUS CS (members) [1][2]5.0AFibre ChannelIBMUltrium 4FSC^^^^^CS-TL
IBM^^^^^ULTRIUM-TD4
  • f97-1
  • f97-2
ETERNUS CS800 S2 [3][4][5]1.4.1_800Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4FSC^^^^^CS-TL
HP^^^^^^Ultrium^4-SCSI
  • f97-3
  • f97-4
  • f97-5
ETERNUS CS800 S3 [3][4][5]2.0.2_800, 2.3.0.1_S3Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5FSC^^^^^CS-TL
HP^^^^^^Ultrium^5-SCSI
  • f97-3
  • f97-4
  • f97-5
ETERNUS CS800 S4 [3][4][5]2.2, 2.3.0.1_S4Fibre ChannelIBMUltrium 5FSC^^^^^CS-TL
IBM^^^^^ULTRIUM-TD5
  • f97-3
  • f97-4
  • f97-5
ETERNUS CS800 S5 [3][4][5]2.3.1Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5FSC^^^^^CS-TL
HP^^^^^^Ultrium^5-SCSI
  • f97-3
  • f97-4
  • f97-5
ETERNUS CS800 S6 [3][4][5]3.2.1Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5FSC^^^^^CS-TL
HP^^^^^^Ultrium^5-SCSI
  • f97-3
  • f97-4
  • f97-5
ETERNUS CS800 S7 [3][4][5]3.5.0_S7Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5FSC^^^^^CS-TL
HP^^^^^^Ultrium^5-SCSI
  • f97-3
  • f97-4
  • f97-5
ETERNUS CS800 [3][4][5]1.4.1_800Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4FSC^^^^^CS-TL
HP^^^^^^Ultrium^4-SCSI
  • f97-3
  • f97-4
  • f97-5
  1. Capacity and compression reporting is not currently supported for this device.
  2. The ETERNUS line was previously known as the CentricStor.
  3. Backup Exec supports Fujitsu's Path-to-Tape (PTT) feature available on this VTL. PTT enables Backup Exec duplication jobs to move data directly from virtual tape to physical tape while off-loading the actual copying of data from the Backup Exec server to the VTL. This is referred to as "DirectCopy to tape" in the Backup Exec Administrator's Guide.
  4. The default port for Backup Exec remote agents may conflict with the NDMP port used for the Path-to-Tape feature. Refer to the following technote to change the default port: http://www.veritas.com/docs/000025898
  5. This VTL also supports the following emulated tape drives: HPE Ultrium 1-SCSI, HPE Ultrium 2-SCSI, HPE Ultrium 3-SCSI, HPE Ultrium 4-SCSI, HPE Ultrium 5-SCSI, IBM ULTRIUM-TD1, IBM ULTRIUM-TD2, IBM ULTRIUM-TD3, IBM ULTRIUM-TD4, and the IBM ULTRIUM-TD5. Older device software versions may not support newer emulated drive generations.
Go to Top of "Virtual Tape Libraries with Drives"

H3C

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
CP3352 [1]Latest from ManufacturerFibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5HP^^^^^^D2DBS
HP^^^^^^Ultrium^5-SCSI
  • f98-1
CP3354 [1]Latest from ManufacturerFibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5HP^^^^^^D2DBS
HP^^^^^^Ultrium^5-SCSI
  • f98-1
CP5510 [1]Latest from ManufacturerFibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5HP^^^^^^D2DBS
HP^^^^^^Ultrium^5-SCSI
  • f98-1
CP5550 [1]Latest from ManufacturerFibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5HP^^^^^^D2DBS
HP^^^^^^Ultrium^5-SCSI
  • f98-1
CP6660 [1]Latest from ManufacturerFibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5HP^^^^^^D2DBS
HP^^^^^^Ultrium^5-SCSI
  • f98-1
  1. This VTL also supports HPE LTO2, LTO3, LTO4, and LTO5 tape drive emulation. These combinations are also supported.
Go to Top of "Virtual Tape Libraries with Drives"

Hewlett Packard Enterprise

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
D2D4000 Series Backup System (members) [1]pf86Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4HP^^^^^^D2DBS
HP^^^^^^Ultrium^4-SCSI
  • f99-1
D2D4100 G2 Series Backup System (members) [1]2.2.10Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5HP^^^^^^D2DBS
HP^^^^^^Ultrium^5-SCSI
  • f99-1
D2D4100 Series Backup System (members) [2]Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4HP^^^^^^D2DBS
HP^^^^^^Ultrium^4-SCSI
  • f99-2
StoreOnce 3500 / 3600 Series (members) [1][3]Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5HP^^^^^^D2DBS
HP^^^^^^Ultrium^5-SCSI
  • f99-1
  • f99-3
StoreOnce 4000 (members) [1][4]Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5HP^^^^^^D2DBS
HP^^^^^^Ultrium^5-SCSI
  • f99-1
  • f99-4
StoreOnce 5000 (members) [1][3]Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5HP^^^^^^D2DBS
HP^^^^^^Ultrium^5-SCSI
  • f99-1
  • f99-3
StoreOnce 6000 (members) [1]3.0.0-1146.6Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5HP^^^^^^D2DBS
HP^^^^^^Ultrium^5-SCSI
  • f99-1
VLS 12000 EVA Gateway [5]2.0Fibre ChannelHewlett Packard EnterpriseUltrium 230 LTO1HP^^^^^^VLS
HP^^^^^^Ultrium^1-SCSI
  • f99-5
VLS 12000 EVA Gateway [5]2.0Fibre ChannelHewlett Packard EnterpriseUltrium 460 LTO2HP^^^^^^VLS
HP^^^^^^Ultrium^2-SCSI
  • f99-5
VLS 12000 EVA Gateway [5]2.0Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3HP^^^^^^VLS
HP^^^^^^Ultrium^3-SCSI
  • f99-5
  1. This VTL also supports HPE LTO2, LTO3, LTO4, and LTO5 tape drive emulation. These combinations are also supported.
  2. This VTL also supports HPE LTO2, LTO3, and LTO4 tape drive emulation. These combinations are also supported.
  3. Version 3.14 code is the minimum required for the StoreOnce 3520, 3540, 5100, & 5500 devices. The code is not backwards compatible with earlier versions of StoreOnce hardware. For more information, please contact Hewlett Packard Enterprise.
  4. This VTL also supports HPE LTO3 and HPE LTO2 tape drive emulation. These combinations are also supported.
  5. HPE supports with maximum block size of 256k
Go to Top of "Virtual Tape Libraries with Drives"

IBM

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
System Storage TS7600 series with ProtecTIER (members) [1][2]2.2.3.16, 3.3.0.0, 3.4.0.0Fibre ChannelIBMTotalStorage 3580 Ultrium 3IBM^^^^^V3584L32
IBM^^^^^ULT3580-TD3
  • f100-1
  • f100-2
Virtualization Engine TS7530 [3][4][5]1.10Fibre ChannelIBMSystem Storage TS2340 Ultrium 4IBM^^^^^TS7530
IBM^^^^^ULT3580-TD4
  • f100-3
  • f100-4
  • f100-5
  1. Capacity and compression reporting is not currently supported for this device.
  2. Minimum firmware level of 2.2.3.16 is required.
  3. Consult with IBM for their "Best Practices" configuration, which is required for ESO.
  4. The maximum Buffer/Block size supported for this device is 128K.
  5. Please note: this device is nearing the end of support. Please see the 'Retiring Soon' section.
Go to Top of "Virtual Tape Libraries with Drives"

NetApp

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
NearStore Virtual Tape Library (members)4.1.2, 5.2.3 (VTL OS)Fibre ChannelIBMUltrium 2NETAPP^^VTL
IBM^^^^^ULTRIUM-TD2
NearStore Virtual Tape Library (members)6.0.1P2Fibre ChannelIBMUltrium 4NETAPP^^VTL
IBM^^^^^ULTRIUM-TD4
Go to Top of "Virtual Tape Libraries with Drives"

Overland Storage

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
REO 4600Fibre ChannelHewlett Packard EnterpriseUltrium 460 LTO2OVERLANDREO^Series
HP^^^^^^Ultrium^2-SCSI
Go to Top of "Virtual Tape Libraries with Drives"

Quantum

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
DXi4700 Series (members) [1]2.3.1, 3.0Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5QUANTUM^DXi
HP^^^^^^Ultrium^5-SCSI
  • f103-1
DXi4800 Series (members) [1][2][3]3.1Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5QUANTUM^DXi
HP^^^^^^Ultrium^5-SCSI
  • f103-1
  • f103-2
  • f103-3
DXi6700 Series (members) [1][2][3][4]1.4.1, 2.0.1, 2.3.0Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4QUANTUM^DXi
HP^^^^^^Ultrium^4-SCSI
  • f103-1
  • f103-2
  • f103-3
  • f103-4
DXi6800 Series (members) [1][2][3]2.2_68Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4QUANTUM^DXi
HP^^^^^^Ultrium^4-SCSI
  • f103-1
  • f103-2
  • f103-3
DXi6900 Series (members) [1][2][3]3.0.0Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5QUANTUM^DXi
HP^^^^^^Ultrium^5-SCSI
  • f103-1
  • f103-2
  • f103-3
DXi7500 Series (members) [2][3][5]1.0, 5.1.312bFibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4QUANTUM^DXi
HP^^^^^^Ultrium^4-SCSI
  • f103-2
  • f103-3
  • f103-5
DXi8500 Series (members) [1][2][3]1.4.2_85, 1.4.5_85Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4QUANTUM^DXi
HP^^^^^^Ultrium^4-SCSI
  • f103-1
  • f103-2
  • f103-3
DXi9000 Series (members) [1][2][3]3.1Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5QUANTUM^DXi
HP^^^^^^Ultrium^5-SCSI
  • f103-1
  • f103-2
  • f103-3
  1. This VTL also supports the following emulated tape drives: HP Ultrium 2-SCSI, HP Ultrium 3-SCSI, HP Ultrium 4-SCSI, HP Ultrium 5-SCSI, IBM ULTRIUM-TD2, IBM ULTRIUM-TD3, IBM ULTRIUM-TD4, and the IBM ULTRIUM-TD5.
  2. Backup Exec supports Quantum's Path-to-Tape (PTT) feature available on this VTL. PTT enables Backup Exec duplication jobs to move data directly from virtual tape to physical tape while off-loading the actual copying of data from the Backup Exec server to the VTL. This is referred to as "DirectCopy to tape" in the Backup Exec Administrator's Guide.
  3. The default port for Backup Exec remote agents may conflict with the NDMP port used for the Path-to-Tape feature. Refer to the following technote to change the default port: http://www.veritas.com/docs/000025898
  4. In order to support 2TB capacity expansions for the DXi6700, Quantum DXi Software 2.0.1 (or higher) is required. Please contact Quantum Service OSR@Quantum.com
  5. This VTL also supports the following emulated tape drives: HPE Ultrium 1-SCSI, HPE Ultrium 2-SCSI, HPE Ultrium 3-SCSI, HPE Ultrium 4-SCSI, IBM ULTRIUM-TD1, IBM ULTRIUM-TD2, IBM ULTRIUM-TD3, IBM ULTRIUM-TD4, Quantum LTO-2, Quantum LTO-3, Quantum SDLT 600, and the Quantum DLT-S4.
Go to Top of "Virtual Tape Libraries with Drives"

Quest

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
DR 13g Series (Dell) (members) [1]4.0Fibre ChannelIBMTotalStorage 3580 Ultrium 4DELL^^^^DR_L700
IBM^^^^^ULT3580-TD4
  • f104-1
DR 13g Series (members) [1][2][3]4.0Fibre ChannelIBMTotalStorage 3580 Ultrium 4QUEST^^^DR_L700
IBM^^^^^ULT3580-TD4
  • f104-1
  • f104-2
  • f104-3
  1. Each VTL may only be assigned to a single server (no sharing).
  2. Minimum DR software of 4.0.2 is required for the Quest inquiry string.
  3. Please see the Quest Migration Guide https://support.quest.com/download/downloads?id=6084223
Go to Top of "Virtual Tape Libraries with Drives"

SEPATON

DeviceMinimum Software VersionLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
S2100 (members)2.1.2Fibre ChannelIBMUltrium 1SEPATON^S2100
IBM^^^^^ULTRIUM-TD1
S2100 (members)2.1.2, 5.2.2Fibre ChannelIBMUltrium 3SEPATON^S2100
IBM^^^^^ULTRIUM-TD3

Virtual Tape Library Families

When a hardware family of devices is listed, refer to this section for a definition of family members. Generally speaking, the family name and members are defined by the hardware manufacturer, and share common operational traits. In some cases, a specific member of the family may not be supported in the same fashion as the other members. When this occurs, a footnote in the hardware category section will indentify this limitation.

Go to Top of "Virtual Tape Library Families"

Dell EMC

BacktrackFamilyInterfaceFamily Members
BacktrackCDL300 SeriesFibre ChannelCDL310
BacktrackDisk Library SeriesFibre ChannelCDL210, CDL300 Series, CDL310, CDL700, CDL700 Series, CDL710, CDL720, CDL740, DL4000 Series, DL6000 Series
Go to Top of "Virtual Tape Library Families"

Dell EMC Data Domain

BacktrackFamilyInterfaceFamily Members
BacktrackAppliance SeriesFibre ChannelDD140, DD160, DD510, DD530, DD560, DD565, DD580, DD610, DD620, DD630, DD640, DD660, DD670, DD690, DD860, DD880, DD890, DD990, DD2200, DD2500, DD3300, DD4200, DD4500, DD6300, DD6800, DD7200, DD9300, DD9500, DD9800
BacktrackDD400 SeriesFibre ChannelDD410, DD430, DD460
Go to Top of "Virtual Tape Library Families"

Fujitsu

BacktrackFamilyInterfaceFamily Members
BacktrackETERNUS CSFibre ChannelETERNUS CS50, ETERNUS CS500, ETERNUS CS1000, ETERNUS CS1500, ETERNUS CS2000, ETERNUS CS3000, ETERNUS CS4000, ETERNUS CS5000, ETERNUS CS8000
Go to Top of "Virtual Tape Library Families"

Hewlett Packard Enterprise

BacktrackFamilyInterfaceFamily Members
BacktrackD2D4000 Series Backup SystemFibre ChannelD2D4004fc Backup System, D2D4009fc Backup System
BacktrackD2D4100 G2 Series Backup SystemFibre ChannelD2D4106fc G2 Backup System, D2D4112 G2 Backup System
BacktrackD2D4100 Series Backup SystemFibre ChannelD2D4112fc Backup System
BacktrackStoreOnce 3500 / 3600 SeriesFibre ChannelStoreOnce 3520, StoreOnce 3540, StoreOnce 3620, StoreOnce 3640
BacktrackStoreOnce 4000Fibre ChannelStoreOnce 4210fc, StoreOnce 4220, StoreOnce 4420, StoreOnce 4430, StoreOnce 4500, StoreOnce 4700, StoreOnce 4900
BacktrackStoreOnce 5000Fibre ChannelStoreOnce 5100, StoreOnce 5500
BacktrackStoreOnce 6000Fibre ChannelStoreOnce 6500, StoreOnce 6600, StoreOnce B6200
Go to Top of "Virtual Tape Library Families"

IBM

BacktrackFamilyInterfaceFamily Members
BacktrackSystem Storage TS7600 series with ProtecTIERFibre ChannelSystem Storage TS7610SM1 ProtecTIER (V-TS3500), System Storage TS7620SM2 ProtecTIER (V-TS3500), System Storage TS7650AP1 ProtecTIER (V-TS3500), System Storage TS7650G ProtecTIER (V-TS3500)
Go to Top of "Virtual Tape Library Families"

NetApp

BacktrackFamilyInterfaceFamily Members
BacktrackNearStore Virtual Tape LibraryFibre ChannelVTL300, VTL600, VTL700, VTL1200, VTL1400
Go to Top of "Virtual Tape Library Families"

Quantum

BacktrackFamilyInterfaceFamily Members
BacktrackDXi4700 SeriesFibre ChannelDXi4701
BacktrackDXi4800 SeriesFibre ChannelDXi4800
BacktrackDXi6700 SeriesFibre ChannelDXi6700, DXi6701, DXi6702
BacktrackDXi6800 SeriesFibre ChannelDXi6802
BacktrackDXi6900 SeriesFibre ChannelDXi6900, DXi6900-S
BacktrackDXi7500 SeriesFibre ChannelDXi7500, DXi7500 Enterprise, DXi7500 Express, DXi7500-N
BacktrackDXi8500 SeriesFibre ChannelDXi8500, DXi8500 2TB, DXi8500 3TB
BacktrackDXi9000 SeriesFibre ChannelDXi9000
Go to Top of "Virtual Tape Library Families"

Quest

BacktrackFamilyInterfaceFamily Members
BacktrackDR 13g Series (Dell)Fibre ChannelDR4300 (Dell), DR4300e (Dell), DR6300 (Dell)
BacktrackDR 13g SeriesFibre ChannelDR4300, DR4300e, DR6300
Go to Top of "Virtual Tape Library Families"

SEPATON

BacktrackFamilyInterfaceFamily Members
BacktrackS2100Fibre ChannelS2100-DS2, S2100-DS3, S2100-ES2, S2100-ES3

Tape Drives

The tape drive support information is listed below. This information is organized by vendor and provides information on the tape drives tested, the supported Inquiry Strings, the type of interface, media type, and any special notes on a per device basis.

Please Note:

1. To ensure support, a device must be supported by Veritas and the device manufacturer.

2. Unless otherwise noted, Veritas tape class drivers were used when testing Windows-supported devices.

3. At times the manufacturer may refer to their devices by product name, which differs from the model name.

4. WORM is supported only on tape drives with a footnote indicating WORM support and a possible minimum firmware or software level. These footnotes are documented in this stand-alone tape drive section. To determine if WORM is supported in an automation environment. (i.e. physical tape libraries), please refer to the tape drive manufacturers stand-alone drive section and check for a footnote. If WORM is supported in the manufacturers drive section, then it is supported in all automation, unless documented otherwise in the automation section.

5. Hardware encryption is supported only on tape drives with a footnote indicating hardware encryption support and a possible minimum firmware or software level. These footnotes are documented in this stand-alone tape drive section. To determine if hardware encryption is supported in an automation environment. (i.e. physical tape libraries), please refer to the tape drive manufacturers stand-alone drive section and check for a footnote. If hardware encryption is supported in the manufacturers drive section, then it is supported in all automation, unless documented otherwise in the automation section.

6. The "ULTRIUM-TD" and the "ULT3580-TD" inquiry strings are interchangeable (both are supported), unless otherwise indicated. The "ULTRIUM-HH" and the "ULT3580-HH" inquiry strings are interchangeable (both are supported), unless otherwise indicated.

7. Unless specifically stated in technote article http://www.veritas.com/docs/000038683 , tape libraries or tape drives attached to a RAID controller are not supported.

8. The HPE One Button Disaster Recovery (OBDR) feature is no longer supported with Backup Exec.

9. The LTO ‘Encrypt Only’ feature is currently not supported with any robotic library or tape drive. This new LTO feature is being investigated by Veritas.

10. Backup Exec supports LTO-7 Type M media (also known as M8 cartridges) in the following manner. These are LTO-7 cartridges that have been formatted to a new LTO-8 standard and their native capacity increased from 6TB to 9TB.

• M8 cartridges are only supported with LTO-8 tape drives, either stand-alone tape drives or in an M8 supported tape library.

• M8 cartridges pre-formatted by the media vendor are supported.

• M8 cartridges manually formatted using hardware vendors’ software tools or tape library firmware features (automatic or manual) are supported.

• Backup Exec does NOT have the ability to convert LTO-7 cartridges to M8 format.

• Backup Exec requires version 20 Update 1 (aka 20.1) (or higher) to support hardware encryption on M8 media.

• Backup Exec requires version 20 Update 1 (aka 20.1) (or higher) to provide pre-configured bar code rules and pre-defined media type for M8 cartridges.

• Customers should use caution when re-labeling the bar code on used LTO-7 cartridges as an LTO-7 cartridge with good data could be accidentally erased in a tape library with firmware that automatically re-initializes tapes with M8 bar codes.

• For details on M8 (formatting methods, technical information, supported barcodes, etc.) please consult the tape hardware documentation or vendor.

• For details on M8 please see https://www.lto.org/technology/typem/

Go to Top of "Tape Drives"

Tape Drive Legend

ValueMeaning
^Character used to denote a space in the INQUIRY STRING.
Character used to denote support for the item listed in the column.
WinBESThe listed device is supported in a Windows Backup Exec Server platform. See the SCL ( http://www.veritas.com/docs/000115689 ) for supported Backup Exec Server Operating System platforms.
RMALThe listed device is supported in a Remote Media Agent for Linux platform. See the SCL ( http://www.veritas.com/docs/000115689 ) for supported Remote Media Agent for Linux platforms.
Go to Top of "Tape Drives"

actidata

DeviceInquiry StringDrive InterfaceMediaWinBESRMAL
actiTape LTO3 - Half HeightIBM^^^^^ULT3580-HH3SCSILTO
actiTape LTO4 - Full HeightIBM^^^^^ULT3580-TD4Fibre ChannelLTO
actiTape LTO4 - Full HeightIBM^^^^^ULT3580-TD4SCSILTO
actiTape LTO4 - Half HeightIBM^^^^^ULT3580-HH4SASLTO
actiTape LTO5 - Full HeightIBM^^^^^ULT3580-TD5Fibre ChannelLTO
actiTape LTO5 - Full HeightIBM^^^^^ULT3580-TD5SASLTO
Go to Top of "Tape Drives"

Dell EMC

DeviceInquiry StringDrive InterfaceMediaWinBESRMAL
PowerVault 114X series [1]variesUSB 2.0
  • f117-1
PowerVault 114X series [1]various^LTO^drivesSAS
  • f117-1
PowerVault LTO-6 [2][3]IBM^^^^^ULTRIUM-HH6SASLTO
  • f117-2
  • f117-3
PowerVault LTO-7 [2][3]IBM^^^^^ULTRIUM-HH7SASLTO
  • f117-2
  • f117-3
PowerVault LTO-8 [2][3]IBM^^^^^ULTRIUM-HH8SASLTO
  • f117-2
  • f117-3
PowerVault LTO4-120 (Quantum) [2][3]QUANTUM^ULTRIUM^4SASLTO
  • f117-2
  • f117-3
PowerVault LTO4-120 [2][3]IBM^^^^^ULTRIUM-TD4SASLTO
  • f117-2
  • f117-3
PowerVault LTO4-120HH [2][3]IBM^^^^^ULTRIUM-HH4SASLTO
  • f117-2
  • f117-3
PowerVault LTO5-140 [2][3]IBM^^^^^ULTRIUM-HH5SASLTO
  • f117-2
  • f117-3
  1. This is a rack mounted enclosure for Dell EMC certified tape drives and should not be confused with actual Dell EMC tape drives.
  2. WORM tape is supported with this drive.
  3. T10 Hardware Encryption is supported.
Go to Top of "Tape Drives"

Hewlett Packard Enterprise

DeviceInquiry StringDrive InterfaceMediaWinBESRMAL
DAT 160 [1]HP^^^^^^DAT160SAS4mm
  • f118-1
DAT 160 [1]HP^^^^^^DAT160SCSI4mm
  • f118-1
DAT 160 [1][2]HP^^^^^^DAT160USB 2.04mm
  • f118-1
  • f118-2
DAT 320 [1][3]HP^^^^^^DAT320SAS4mm
  • f118-1
  • f118-3
DAT 320 [1][2][3]HP^^^^^^DAT320USB 2.04mm
  • f118-1
  • f118-2
  • f118-3
Ultrium 920 LTO3 [1][4][5]HP^^^^^^Ultrium^3-SCSISASLTO
  • f118-1
  • f118-4
  • f118-5
Ultrium 920 LTO3 [1][4][5]HP^^^^^^Ultrium^3-SCSISCSILTO
  • f118-1
  • f118-4
  • f118-5
Ultrium 1760 LTO4 [1][3][4][5]HP^^^^^^Ultrium^4-SCSIFibre ChannelLTO
  • f118-1
  • f118-3
  • f118-4
  • f118-5
Ultrium 1760 LTO4 [1][3][4][5]HP^^^^^^Ultrium^4-SCSISASLTO
  • f118-1
  • f118-3
  • f118-4
  • f118-5
Ultrium 1760 LTO4 [1][3][4][5]HP^^^^^^Ultrium^4-SCSISCSILTO
  • f118-1
  • f118-3
  • f118-4
  • f118-5
Ultrium 1840 LTO4 [1][3]HP^^^^^^Ultrium^4-SCSIFibre ChannelLTO
  • f118-1
  • f118-3
Ultrium 1840 LTO4 [1][3]HP^^^^^^Ultrium^4-SCSISASLTO
  • f118-1
  • f118-3
Ultrium 1840 LTO4 [1][3]HP^^^^^^Ultrium^4-SCSISCSILTO
  • f118-1
  • f118-3
Ultrium 3000 LTO5 [1][3][4]HP^^^^^^Ultrium^5-SCSIFibre ChannelLTO
  • f118-1
  • f118-3
  • f118-4
Ultrium 3000 LTO5 [1][3][4]HP^^^^^^Ultrium^5-SCSISASLTO
  • f118-1
  • f118-3
  • f118-4
Ultrium 3280 LTO5 [1][3]HP^^^^^^Ultrium^5-SCSIFibre ChannelLTO
  • f118-1
  • f118-3
Ultrium 3280 LTO5 [1][3]HP^^^^^^Ultrium^5-SCSISASLTO
  • f118-1
  • f118-3
Ultrium 6250 LTO6 [1][3][4]HP^^^^^^Ultrium^6-SCSIFibre ChannelLTO
  • f118-1
  • f118-3
  • f118-4
Ultrium 6250 LTO6 [1][3][4]HP^^^^^^Ultrium^6-SCSISASLTO
  • f118-1
  • f118-3
  • f118-4
Ultrium 6650 LTO6 [1][3]HP^^^^^^Ultrium^6-SCSIFibre ChannelLTO
  • f118-1
  • f118-3
Ultrium 6650 LTO6 [1][3]HP^^^^^^Ultrium^6-SCSISASLTO
  • f118-1
  • f118-3
Ultrium 15000 LTO7 [1][3][4]HP^^^^^^Ultrium^7-SCSIFibre ChannelLTO
  • f118-1
  • f118-3
  • f118-4
Ultrium 15000 LTO7 [1][3][4]HP^^^^^^Ultrium^7-SCSISASLTO
  • f118-1
  • f118-3
  • f118-4
Ultrium 15750 LTO7 [1][3]HP^^^^^^Ultrium^7-SCSIFibre ChannelLTO
  • f118-1
  • f118-3
Ultrium 30750 LTO8 [1][3][4]HPE^^^^^Ultrium^8-SCSIFibre ChannelLTO
  • f118-1
  • f118-3
  • f118-4
Ultrium 30750 LTO8 [1][3][4]HPE^^^^^Ultrium^8-SCSISASLTO
  • f118-1
  • f118-3
  • f118-4
  1. WORM tape is supported with this drive.
  2. For all USB tape drives, the vendor's device driver must be loaded prior to starting Backup Exec.
  3. T10 Hardware Encryption is supported.
  4. Half-Height drive configuration.
  5. Supported in the HPE BladeSystem c-Class chassis.
Go to Top of "Tape Drives"

IBM

DeviceInquiry StringDrive InterfaceMediaWinBESRMAL
LTO Gen 3 400/800GB (P/N 25R0012 / 39M5657)IBM^^^^^ULTRIUM-TD3SCSILTO
LTO Gen 3 HH (P/N 43W8478/3628L3X/3628N3X) [1]IBM^^^^^HH^LTO^Gen^3SASLTO
  • f119-1
LTO Gen 4 HH (P/N 44E8895/3628L4X/3628N4X) [1][2]IBM^^^^^HH^LTO^Gen^4SASLTO
  • f119-1
  • f119-2
LTO Gen 5 HH (P/N 49Y9898/3628L5X/3628N5X) [1][2]IBM^^^^^HH^LTO^Gen^5SASLTO
  • f119-1
  • f119-2
LTO Gen 6 HH (P/N 00D8924) [1][2]IBM^^^^^HH^LTO^Gen^6SASLTO
  • f119-1
  • f119-2
System Storage TS1140 (3592 Model E07) [3][4]IBM^^^^^03592E07Fibre Channelhalf inch
  • f119-3
  • f119-4
System Storage TS1150 (3592 Model E08) [3][4]IBM^^^^^03592E08Fibre Channelhalf inch
  • f119-3
  • f119-4
System Storage TS2230 Ultrium 3 Half Height [1]IBM^^^^^ULT3580-HH3SASLTO
  • f119-1
System Storage TS2230 Ultrium 3 Half Height [1]IBM^^^^^ULT3580-HH3SCSILTO
  • f119-1
System Storage TS2240 Ultrium 4 Half Height [2]IBM^^^^^ULT3580-HH4Fibre ChannelLTO
  • f119-2
System Storage TS2240 Ultrium 4 Half Height [1][2]IBM^^^^^ULT3580-HH4SASLTO
  • f119-1
  • f119-2
System Storage TS2250 Ultrium 5 Half Height [1][2]IBM^^^^^ULT3580-HH5Fibre ChannelLTO
  • f119-1
  • f119-2
System Storage TS2250 Ultrium 5 Half Height [1][2]IBM^^^^^ULT3580-HH5SASLTO
  • f119-1
  • f119-2
System Storage TS2260 Ultrium 6 Half Height [1][2]IBM^^^^^ULT3580-HH6Fibre ChannelLTO
  • f119-1
  • f119-2
System Storage TS2260 Ultrium 6 Half Height [1][2]IBM^^^^^ULT3580-HH6SASLTO
  • f119-1
  • f119-2
System Storage TS2270 Ultrium 7 Half Height [1][2]IBM^^^^^ULT3580-HH7Fibre ChannelLTO
  • f119-1
  • f119-2
System Storage TS2270 Ultrium 7 Half Height [1][2]IBM^^^^^ULT3580-HH7SASLTO
  • f119-1
  • f119-2
System Storage TS2280 Ultrium 8 Half Height [1][2]IBM^^^^^ULT3580-HH8Fibre ChannelLTO
  • f119-1
  • f119-2
System Storage TS2280 Ultrium 8 Half Height [1][2]IBM^^^^^ULT3580-HH8SASLTO
  • f119-1
  • f119-2
System Storage TS2340 Ultrium 4 [1][2]IBM^^^^^ULT3580-TD4Fibre ChannelLTO
  • f119-1
  • f119-2
System Storage TS2340 Ultrium 4 [1][2]IBM^^^^^ULT3580-TD4SASLTO
  • f119-1
  • f119-2
System Storage TS2340 Ultrium 4 [1]IBM^^^^^ULT3580-TD4SCSILTO
  • f119-1
System Storage TS2350 Ultrium 5 [1][2]IBM^^^^^ULT3580-TD5Fibre ChannelLTO
  • f119-1
  • f119-2
System Storage TS2350 Ultrium 5 [1][2]IBM^^^^^ULT3580-TD5SASLTO
  • f119-1
  • f119-2
System Storage TS2360 Ultrium 6 [1][2]IBM^^^^^ULT3580-TD6Fibre ChannelLTO
  • f119-1
  • f119-2
System Storage TS2360 Ultrium 6 [1][2]IBM^^^^^ULT3580-TD6SASLTO
  • f119-1
  • f119-2
System Storage TS2370 Ultrium 7 [1][2]IBM^^^^^ULT3580-TD7Fibre ChannelLTO
  • f119-1
  • f119-2
System Storage TS2380 Ultrium 8 [1][2]IBM^^^^^ULT3580-TD8Fibre ChannelLTO
  • f119-1
  • f119-2
TotalStorage 3580 Ultrium 3 [5]IBM^^^^^ULT3580-TD3Fibre ChannelLTO
  • f119-5
TotalStorage 3580 Ultrium 3 [5]IBM^^^^^ULT3580-TD3SCSILTO
  • f119-5
Ultrium 3 Half Height [5]IBM^^^^^ULTRIUM-HH3SASLTO
  • f119-5
Ultrium 3 Half Height [5]IBM^^^^^ULTRIUM-HH3SCSILTO
  • f119-5
Ultrium 3 [5]IBM^^^^^ULTRIUM-TD3Fibre ChannelLTO
  • f119-5
Ultrium 3 [5]IBM^^^^^ULTRIUM-TD3SCSILTO
  • f119-5
Ultrium 4 (U160) [1]IBM^^^^^ULTRIUM-TD4SCSILTO
  • f119-1
Ultrium 4 (U320) [1][2]IBM^^^^^ULTRIUM-TD4SCSILTO
  • f119-1
  • f119-2
Ultrium 4 Half Height (U320) [1][2]IBM^^^^^ULTRIUM-HH4SCSILTO
  • f119-1
  • f119-2
Ultrium 4 Half Height [1][2]IBM^^^^^ULTRIUM-HH4Fibre ChannelLTO
  • f119-1
  • f119-2
Ultrium 4 Half Height [1][2]IBM^^^^^ULTRIUM-HH4SASLTO
  • f119-1
  • f119-2
Ultrium 4 [1][2]IBM^^^^^ULTRIUM-TD4Fibre ChannelLTO
  • f119-1
  • f119-2
Ultrium 4 [1][2]IBM^^^^^ULTRIUM-TD4SASLTO
  • f119-1
  • f119-2
Ultrium 5 Half Height [1][2]IBM^^^^^ULTRIUM-HH5Fibre ChannelLTO
  • f119-1
  • f119-2
Ultrium 5 Half Height [1][2]IBM^^^^^ULTRIUM-HH5SASLTO
  • f119-1
  • f119-2
Ultrium 5 [1][2]IBM^^^^^ULTRIUM-TD5Fibre ChannelLTO
  • f119-1
  • f119-2
Ultrium 5 [1][2]IBM^^^^^ULTRIUM-TD5SASLTO
  • f119-1
  • f119-2
Ultrium 6 Half Height [1][2]IBM^^^^^ULTRIUM-HH6Fibre ChannelLTO
  • f119-1
  • f119-2
Ultrium 6 Half Height [1][2]IBM^^^^^ULTRIUM-HH6SASLTO
  • f119-1
  • f119-2
Ultrium 6 [1][2]IBM^^^^^ULTRIUM-TD6Fibre ChannelLTO
  • f119-1
  • f119-2
Ultrium 6 [1][2]IBM^^^^^ULTRIUM-TD6SASLTO
  • f119-1
  • f119-2
Ultrium 7 Half Height [1][2]IBM^^^^^ULTRIUM-HH7Fibre ChannelLTO
  • f119-1
  • f119-2
Ultrium 7 Half Height [1][2]IBM^^^^^ULTRIUM-HH7SASLTO
  • f119-1
  • f119-2
Ultrium 7 [1][2]IBM^^^^^ULTRIUM-TD7Fibre ChannelLTO
  • f119-1
  • f119-2
Ultrium 8 Half Height [1][2]IBM^^^^^ULTRIUM-HH8Fibre ChannelLTO
  • f119-1
  • f119-2
Ultrium 8 Half Height [1][2]IBM^^^^^ULTRIUM-HH8SASLTO
  • f119-1
  • f119-2
Ultrium 8 [1][2]IBM^^^^^ULTRIUM-TD8Fibre ChannelLTO
  • f119-1
  • f119-2
  1. WORM tape is supported with this drive.
  2. T10 Hardware Encryption is supported.
  3. Capacity and compression reporting is not currently supported for this device.
  4. WORM tape is not supported with this drive.
  5. WORM tape is supported with initial firmware level 5480
Go to Top of "Tape Drives"

Imation

DeviceInquiry StringDrive InterfaceMediaWinBESRMAL
LR1100 LTO 1U Storage EnclosurevariesSAS
Ultrium 4 Half Height [1][2]IBM^^^^^ULTRIUM-HH4SASLTO
  • f120-1
  • f120-2
Ultrium 5 Half Height [1][2]IBM^^^^^ULTRIUM-HH5SASLTO
  • f120-1
  • f120-2
  1. WORM tape is supported with this drive.
  2. T10 Hardware Encryption is supported.
Go to Top of "Tape Drives"

Oracle

DeviceInquiry StringDrive InterfaceMediaWinBESRMAL
StorageTek T10000D [1]STK^^^^^T10000DFibre Channelhalf inch
  • f121-1
  1. WORM tape is supported with this drive.
Go to Top of "Tape Drives"

Quantum

DeviceInquiry StringDrive InterfaceMediaWinBESRMAL
LTO-3 HH [1]QUANTUM^ULTRIUM^3Fibre ChannelLTO
  • f122-1
LTO-3 HH [1]QUANTUM^ULTRIUM^3SASLTO
  • f122-1
LTO-3 HH [2]QUANTUM^ULTRIUM^3SCSILTO
  • f122-2
LTO-4 HH [1][3]QUANTUM^ULTRIUM^4SASLTO
  • f122-1
  • f122-3
LTO-4 HH [1][3]QUANTUM^ULTRIUM^4SCSILTO
  • f122-1
  • f122-3
LTO-5 FH [1][3]QUANTUM^ULTRIUM^5SASLTO
  • f122-1
  • f122-3
LTO-5 HH [1][3]QUANTUM^ULTRIUM^5SASLTO
  • f122-1
  • f122-3
LTO-6 HH [1][3]QUANTUM^ULTRIUM^6SASLTO
  • f122-1
  • f122-3
Ultrium 4 HH [1][3]QUANTUM^ULTRIUM-HH4SASLTO
  • f122-1
  • f122-3
Ultrium 5 HH [1][3]QUANTUM^ULTRIUM-HH5SASLTO
  • f122-1
  • f122-3
Ultrium 6 HH [1][3]QUANTUM^ULTRIUM-HH6SASLTO
  • f122-1
  • f122-3
Ultrium 7 HH [1][3]QUANTUM^ULTRIUM-HH7SASLTO
  • f122-1
  • f122-3
Ultrium 8 HH [1][3]QUANTUM^ULTRIUM-HH8SASLTO
  • f122-1
  • f122-3
  1. WORM tape is supported with this drive.
  2. WORM tape is supported with initial firmware level 1896
  3. T10 Hardware Encryption is supported.
Go to Top of "Tape Drives"

StorageTek

DeviceInquiry StringDrive InterfaceMediaWinBESRMAL
T9840CSTK^^^^^T9840CFibre Channelhalf inch
T10000A 4GBSTK^^^^^T10000AFibre Channelhalf inch
T10000BSTK^^^^^T10000BFibre Channelhalf inch
T10000CSTK^^^^^T10000CFibre Channelhalf inch
Go to Top of "Tape Drives"

Sun

DeviceInquiry StringDrive InterfaceMediaWinBESRMAL
LTO3 HHHP^^^^^^Ultrium^3-SCSISASLTO
LTO3 HHHP^^^^^^Ultrium^3-SCSISCSILTO
LTO4 HHHP^^^^^^Ultrium^4-SCSISASLTO
LTO4 HHHP^^^^^^Ultrium^4-SCSISCSILTO
Go to Top of "Tape Drives"

Tandberg

DeviceInquiry StringDrive InterfaceMediaWinBESRMAL
840LTOIBM^^^^^ULTRIUM-TD3SCSILTO
1640LTO [1]IBM^^^^^ULTRIUM-TD4SASLTO
  • f125-1
1640LTO [1]IBM^^^^^ULTRIUM-TD4SCSILTO
  • f125-1
DAT 160 [1]HP^^^^^^DAT160SCSI4mm
  • f125-1
DAT 160 [1][2]HP^^^^^^DAT160USB 2.04mm
  • f125-1
  • f125-2
DAT 320 [1][3]HP^^^^^^DAT320SAS4mm
  • f125-1
  • f125-3
DAT 320 [1][2][3]HP^^^^^^DAT320USB 2.04mm
  • f125-1
  • f125-2
  • f125-3
HH LTO 3 [1]TANDBERGLTO-3^HHSASLTO
  • f125-1
HH LTO 3 [1]TANDBERGLTO-3^HHSCSILTO
  • f125-1
HH LTO 4 [1][3]TANDBERGLTO-4^HHSASLTO
  • f125-1
  • f125-3
HH LTO 4 [1][3]TANDBERGLTO-4^HHSCSILTO
  • f125-1
  • f125-3
HH LTO 5 [1][3]TANDBERGLTO-5^HHFibre ChannelLTO
  • f125-1
  • f125-3
HH LTO 5 [1][3]TANDBERGLTO-5^HHSASLTO
  • f125-1
  • f125-3
HH LTO 6 [1][3]TANDBERGLTO-6^HHFibre ChannelLTO
  • f125-1
  • f125-3
HH LTO 6 [1][3]TANDBERGLTO-6^HHSASLTO
  • f125-1
  • f125-3
  1. WORM tape is supported with this drive.
  2. For all USB tape drives, the vendor's device driver must be loaded prior to starting Backup Exec for Windows Servers.
  3. T10 Hardware Encryption is supported.
Go to Top of "Tape Drives"

UNITEX

DeviceInquiry StringDrive InterfaceMediaWinBESRMAL
LT40 USB [1][2]IBM^^^^^HH^LTO^Gen^4USBLTO
  • f126-1
  • f126-2
LT50 USB [1][2]IBM^^^^^HH^LTO^Gen^5USBLTO
  • f126-1
  • f126-2
LT60 SAS [2]IBM^^^^^HH^LTO^Gen^6SASLTO
  • f126-2
LT60 USB [1][2]IBM^^^^^HH^LTO^Gen^6USBLTO
  • f126-1
  • f126-2
LT70H [2]IBM^^^^^ULTRIUM-HH7SASLTO
  • f126-2
LT70H [1][2]IBM^^^^^ULTRIUM-HH7USBLTO
  • f126-1
  • f126-2
LT80H [2]IBM^^^^^ULTRIUM-HH8SASLTO
  • f126-2
LT80H [1][2]IBM^^^^^ULTRIUM-HH8USBLTO
  • f126-1
  • f126-2
  1. Backup Exec Simplified Disaster Recovery (SDR) is not supported.
  2. T10 Hardware Encryption is supported.

Tape Libraries with Drives

The library support information is listed below. This information is organized by vendor manufacturer/model, inquiry string (vendor ID + product ID), the interface of the library, and any other important notes or information relevant to the hardware and its compatibility.

Partitioning a library using the library management for sharing between applications and/or servers is a hardware specific feature available in certain library storage systems. Customers using this hardware feature with Backup Exec are supported, but due the variations in design and implementation, technical support is provided in a "reasonable effort" basis only. This means that Veritas Technical Support will work with customers to resolve issues associated only with the Backup Exec portion of the shared configurations, and any issues that cannot be duplicated outside of the shared environment will be the responsibility of the OEM hardware vendor to support.

Please Note:

1. This listing is for library support and the tape drive it was tested with. If a tape library is configured with a drive other than that listed, it has not been tested and will not be supported.

2. Tested iSCSI versions of tape libraries are listed in the "iSCSI Solutions" section, under the "SAN Infrastructure components" bookmark. Please reference the limitations listed in that section.

3. The "ULTRIUM-TD" and the "ULT3580-TD" inquiry strings are interchangeable (both are supported), unless otherwise indicated. The "ULTRIUM-HH" and the "ULT3580-HH" inquiry strings are interchangeable (both are supported), unless otherwise indicated.

4. Unless specifically stated in technote article http://www.veritas.com/docs/000038683 , tape libraries or tape drives attached to a RAID controller are not supported.

5. Libraries or drives with an interface column of "SCSI" require an interface card or bridge to establish a connection to an FC switch. Please see the "SAN Infrastructure components/Fibre Channel Infrastructure/Bridges and Routers" section for supported devices.

6. Please refer to the stand-alone tape drive section (above) and look under the drive manufacturer to determine WORM or hardware encryption support status.

7. The LTO ‘Encrypt Only’ feature is currently not supported with any robotic library or tape drive. This new LTO feature is being investigated by Veritas.

Go to Top of "Tape Libraries with Drives"

Tape Library Legend

ValueMeaning
^Character used to denote a space in the INQUIRY STRING.
Character used to denote support for the item listed in the column.
WinBESThe listed device is supported in a Windows Backup Exec Server platform. Shareability is determined by the ESO column. See the SCL ( http://www.veritas.com/docs/000115689 ) for supported Backup Exec Server Operating System platforms.
RMALThe listed device is supported in a Remote Media Agent for Linux platform. Shareability is determined by the ESO column. See the SCL ( http://www.veritas.com/docs/000115689 ) for supported Remote Media Agent for Linux platforms.
NDMPThe listed device is supported for use with NDMP. See the "NDMP Option" section for platform specific details. Shareability is determined by the ESO column.
ESOThe listed device is supported by the Enterprise Server Option using Fibre Channel. ESO refers to WinBES, and optionally RMAL or NDMP.
Go to Top of "Tape Libraries with Drives"

actidata

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
actiLib seriesFibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^3-SCSI
actiLib seriesFibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
actiLib seriesFibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
actiLib seriesFibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^5-SCSI
actiLib seriesSASHewlett Packard EnterpriseUltrium 920 LTO3SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^3-SCSI
actiLib seriesSASHewlett Packard EnterpriseUltrium 1760 LTO4SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
actiLib seriesSASHewlett Packard EnterpriseUltrium 1840 LTO4SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
actiLib seriesSASHewlett Packard EnterpriseUltrium 3000 LTO5SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^5-SCSI
actiLib seriesSASHewlett Packard EnterpriseUltrium 3280 LTO5SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^5-SCSI
actiLib seriesSCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^3-SCSI
actiLib seriesSCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^3-SCSI
actiLib seriesSCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
actiLib seriesSCSIHewlett Packard EnterpriseUltrium 1840 LTO4SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
Go to Top of "Tape Libraries with Drives"

ADIC

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
Scalar i500Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelADIC^^^^Scalar^i500
IBM^^^^^ULT3580-TD3
Scalar i500Fibre ChannelIBMUltrium 3Fibre ChannelADIC^^^^Scalar^i500
IBM^^^^^ULTRIUM-TD3
Scalar i500 [1]Fibre ChannelIBMUltrium 4Fibre ChannelADIC^^^^Scalar^i500
IBM^^^^^ULTRIUM-TD4
  • f129-1
Scalar i500 [1]SASIBMUltrium 4SASADIC^^^^Scalar^i500
IBM^^^^^ULTRIUM-TD4
  • f129-1
Scalar i500SCSIIBMTotalStorage 3580 Ultrium 3SCSIADIC^^^^Scalar^i500
IBM^^^^^ULT3580-TD3
Scalar i500SCSIIBMUltrium 3SCSIADIC^^^^Scalar^i500
IBM^^^^^ULTRIUM-TD3
Scalar i500 [1]SCSIIBMUltrium 4 (U160)SCSIADIC^^^^Scalar^i500
IBM^^^^^ULTRIUM-TD4
  • f129-1
  1. L1 barcode labels on a cleaning media will cause a cleaning utility job to hang indefinitely. Recommend using L2 (or above) barcode labels for cleaning media.
Go to Top of "Tape Libraries with Drives"

BDT

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
FlexStor IIFibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^3-SCSI
FlexStor IIFibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
FlexStor IIFibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
FlexStor IIFibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^5-SCSI
FlexStor IIFibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^5-SCSI
FlexStor IIFibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^6-SCSI
FlexStor IIFibre ChannelIBMUltrium 5 Half HeightFibre ChannelBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH5
FlexStor IIFibre ChannelIBMUltrium 5Fibre ChannelBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-TD5
FlexStor IIFibre ChannelIBMUltrium 6 Half HeightFibre ChannelBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH6
FlexStor IIFibre ChannelIBMUltrium 7 Half HeightFibre ChannelBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH7
FlexStor IIFibre ChannelIBMUltrium 8 Half HeightFibre ChannelBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH8
FlexStor IISASHewlett Packard EnterpriseUltrium 920 LTO3SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^3-SCSI
FlexStor IISASHewlett Packard EnterpriseUltrium 1760 LTO4SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
FlexStor IISASHewlett Packard EnterpriseUltrium 1840 LTO4SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
FlexStor IISASHewlett Packard EnterpriseUltrium 3000 LTO5SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^5-SCSI
FlexStor IISASHewlett Packard EnterpriseUltrium 3280 LTO5SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^5-SCSI
FlexStor IISASHewlett Packard EnterpriseUltrium 6250 LTO6SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^6-SCSI
FlexStor IISASIBMUltrium 5 Half HeightSASBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH5
FlexStor IISASIBMUltrium 5SASBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-TD5
FlexStor IISASIBMUltrium 6 Half HeightSASBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH6
FlexStor IISASIBMUltrium 7 Half HeightSASBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH7
FlexStor IISASIBMUltrium 8 Half HeightSASBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH8
FlexStor IISCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^3-SCSI
FlexStor IISCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^3-SCSI
FlexStor IISCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
FlexStor IISCSIHewlett Packard EnterpriseUltrium 1840 LTO4SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
MultiStakFibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelBDT^^^^^MULTISTAK
HP^^^^^^Ultrium^5-SCSI
MultiStakFibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelBDT^^^^^MULTISTAK
HP^^^^^^Ultrium^6-SCSI
MultiStak [1]Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH5
  • f130-1
MultiStak [1]Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH6
  • f130-1
MultiStakFibre ChannelIBMUltrium 7 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH7
MultiStakFibre ChannelIBMUltrium 8 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH8
MultiStakSASHewlett Packard EnterpriseUltrium 3000 LTO5SASBDT^^^^^MULTISTAK
HP^^^^^^Ultrium^5-SCSI
MultiStakSASHewlett Packard EnterpriseUltrium 6250 LTO6SASBDT^^^^^MULTISTAK
HP^^^^^^Ultrium^6-SCSI
MultiStak [1]SASIBMUltrium 5 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH5
  • f130-1
MultiStak [1]SASIBMUltrium 6 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH6
  • f130-1
MultiStakSASIBMUltrium 7 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH7
MultiStakSASIBMUltrium 8 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH8
MultiStorFibre ChannelIBMUltrium 6 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH6
MultiStorFibre ChannelIBMUltrium 7 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH7
MultiStorFibre ChannelIBMUltrium 8 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH8
MultiStorSASIBMUltrium 6 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH6
MultiStorSASIBMUltrium 7 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH7
MultiStorSASIBMUltrium 8 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH8
ThinStorPlusSCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSIBDT^^^^^ThinStorPlus^AL
HP^^^^^^Ultrium^3-SCSI
ThinStorPlusSCSIIBMTotalStorage 3580 Ultrium 3SCSIBDT^^^^^ThinStorPlus^AL
IBM^^^^^ULT3580-TD3
ThinStorPlus SM2SCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSIBDT^^^^^ThinStorPlus^SM2
HP^^^^^^Ultrium^3-SCSI
ThinStorPlus SM2SCSIIBMTotalStorage 3580 Ultrium 3SCSIBDT^^^^^ThinStorPlus^SM2
IBM^^^^^ULT3580-TD3
  1. Library firmware of 2.00 or higher is recommended.
Go to Top of "Tape Libraries with Drives"

Dell EMC

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
ML3Fibre ChannelIBMSystem Storage TS2260 Ultrium 6 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH6
ML3Fibre ChannelIBMSystem Storage TS2270 Ultrium 7 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH7
ML3Fibre ChannelIBMSystem Storage TS2280 Ultrium 8 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH8
ML3Fibre ChannelIBMSystem Storage TS2360 Ultrium 6Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD6
ML3Fibre ChannelIBMSystem Storage TS2370 Ultrium 7Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD7
ML3Fibre ChannelIBMSystem Storage TS2380 Ultrium 8Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD8
ML3SASIBMSystem Storage TS2260 Ultrium 6 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH6
ML3SASIBMSystem Storage TS2270 Ultrium 7 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH7
ML3SASIBMSystem Storage TS2280 Ultrium 8 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH8
PowerVault 124TSASIBMUltrium 3 Half HeightSASDELL^^^^PV-124T
IBM^^^^^ULTRIUM-HH3
PowerVault 124TSASIBMUltrium 4 Half HeightSASDELL^^^^PV-124T
IBM^^^^^ULTRIUM-HH4
PowerVault 124TSASIBMUltrium 4SASDELL^^^^PV-124T
IBM^^^^^ULTRIUM-TD4
PowerVault 124TSASIBMUltrium 6 Half HeightSASDELL^^^^PV-124T
IBM^^^^^ULTRIUM-HH6
PowerVault 124TSASQuantumLTO-3 HHSASDELL^^^^PV-124T
QUANTUM^ULTRIUM^3
PowerVault 124TSASQuantumLTO-4 HHSASDELL^^^^PV-124T
QUANTUM^ULTRIUM^4
PowerVault 124TSASQuantumLTO-5 FHSASDELL^^^^PV-124T
QUANTUM^ULTRIUM^5
PowerVault 124TSCSIIBMUltrium 3SCSIDELL^^^^PV-124T
IBM^^^^^ULTRIUM-TD3
PowerVault 124TSCSIQuantumLTO-3 HHSCSIDELL^^^^PV-124T
QUANTUM^ULTRIUM^3
PowerVault ML6000 Series (members) [1]Fibre ChannelIBMSystem Storage TS2350 Ultrium 5Fibre ChannelADIC^^^^Scalar^i500
IBM^^^^^ULT3580-TD5
  • f131-1
PowerVault ML6000 Series (members)Fibre ChannelIBMSystem Storage TS2360 Ultrium 6Fibre ChannelADIC^^^^Scalar^i500
IBM^^^^^ULT3580-TD6
PowerVault ML6000 Series (members)Fibre ChannelIBMSystem Storage TS2370 Ultrium 7Fibre ChannelADIC^^^^Scalar^i500
IBM^^^^^ULT3580-TD7
PowerVault ML6000 Series (members)Fibre ChannelIBMSystem Storage TS2380 Ultrium 8Fibre ChannelADIC^^^^Scalar^i500
IBM^^^^^ULT3580-TD8
PowerVault ML6000 Series (members)Fibre ChannelIBMUltrium 3Fibre ChannelADIC^^^^Scalar^i500
IBM^^^^^ULTRIUM-TD3
PowerVault ML6000 Series (members) [2]Fibre ChannelIBMUltrium 4Fibre ChannelADIC^^^^Scalar^i500
IBM^^^^^ULTRIUM-TD4
  • f131-2
PowerVault ML6000 Series (members)SASIBMSystem Storage TS2350 Ultrium 5SASADIC^^^^Scalar^i500
IBM^^^^^ULT3580-TD5
PowerVault ML6000 Series (members)SASIBMSystem Storage TS2360 Ultrium 6SASADIC^^^^Scalar^i500
IBM^^^^^ULT3580-TD6
PowerVault ML6000 Series (members) [2]SASIBMUltrium 4SASADIC^^^^Scalar^i500
IBM^^^^^ULTRIUM-TD4
  • f131-2
PowerVault ML6000 Series (members)SCSIIBMUltrium 3SCSIADIC^^^^Scalar^i500
IBM^^^^^ULTRIUM-TD3
PowerVault TL1000SASIBMSystem Storage TS2240 Ultrium 4 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULT3580-HH4
PowerVault TL1000SASIBMSystem Storage TS2250 Ultrium 5 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULT3580-HH5
PowerVault TL1000SASIBMSystem Storage TS2260 Ultrium 6 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULT3580-HH6
PowerVault TL1000SASIBMSystem Storage TS2270 Ultrium 7 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULT3580-HH7
PowerVault TL1000SASIBMSystem Storage TS2280 Ultrium 8 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULT3580-HH8
PowerVault TL2000/TL4000 series (members)Fibre ChannelIBMSystem Storage TS2240 Ultrium 4 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH4
PowerVault TL2000/TL4000 series (members)Fibre ChannelIBMSystem Storage TS2250 Ultrium 5 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH5
PowerVault TL2000/TL4000 series (members)Fibre ChannelIBMSystem Storage TS2260 Ultrium 6 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH6
PowerVault TL2000/TL4000 series (members)Fibre ChannelIBMSystem Storage TS2270 Ultrium 7 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH7
PowerVault TL2000/TL4000 series (members)Fibre ChannelIBMSystem Storage TS2280 Ultrium 8 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH8
PowerVault TL2000/TL4000 series (members)Fibre ChannelIBMSystem Storage TS2340 Ultrium 4Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD4
PowerVault TL2000/TL4000 series (members)Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD3
PowerVault TL2000/TL4000 series (members) [3]SASIBMSystem Storage TS2230 Ultrium 3 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH3
  • f131-3
PowerVault TL2000/TL4000 series (members)SASIBMSystem Storage TS2240 Ultrium 4 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH4
PowerVault TL2000/TL4000 series (members) [3]SASIBMSystem Storage TS2250 Ultrium 5 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH5
  • f131-3
PowerVault TL2000/TL4000 series (members)SASIBMSystem Storage TS2260 Ultrium 6 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH6
PowerVault TL2000/TL4000 series (members)SASIBMSystem Storage TS2270 Ultrium 7 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH7
PowerVault TL2000/TL4000 series (members)SASIBMSystem Storage TS2280 Ultrium 8 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH8
PowerVault TL2000/TL4000 series (members) [3]SASIBMSystem Storage TS2340 Ultrium 4SASIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD4
  • f131-3
PowerVault TL2000/TL4000 series (members) [3]SASIBMUltrium 4 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH4
  • f131-3
PowerVault TL2000/TL4000 series (members)SCSIIBMTotalStorage 3580 Ultrium 3SCSIIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD3
  1. L1 and L2 barcode labels on a cleaning media will cause a cleaning utility job to hang indefinitely. Recommend using L3 (or above) barcode labels for cleaning media.
  2. L1 barcode labels on a cleaning media will cause a cleaning utility job to hang indefinitely. Recommend using L2 (or above) barcode labels for cleaning media.
  3. ESO is only supported with the TL24iSCSIxSAS blade.
Go to Top of "Tape Libraries with Drives"

Fujitsu

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
ETERNUS LT20Fibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelFSC^^^^^FibreCAT^TX08
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT20Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelFSC^^^^^FibreCAT^TX08
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT20SASHewlett Packard EnterpriseUltrium 920 LTO3SASFSC^^^^^FibreCAT^TX08
HP^^^^^^Ultrium^3-SCSI
ETERNUS LT20SASHewlett Packard EnterpriseUltrium 1760 LTO4SASFSC^^^^^FibreCAT^TX08
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT20SASHewlett Packard EnterpriseUltrium 3000 LTO5SASFSC^^^^^FibreCAT^TX08
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT20/40/60 S2 (members)Fibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelFUJITSU^ETERNUS^LT^S2
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT20/40/60 S2 (members) [1]Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelFUJITSU^ETERNUS^LT^S2
HP^^^^^^Ultrium^4-SCSI
  • f132-1
ETERNUS LT20/40/60 S2 (members)Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelFUJITSU^ETERNUS^LT^S2
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT20/40/60 S2 (members) [1]Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelFUJITSU^ETERNUS^LT^S2
HP^^^^^^Ultrium^5-SCSI
  • f132-1
ETERNUS LT20/40/60 S2 (members)Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelFUJITSU^ETERNUS^LT^S2
HP^^^^^^Ultrium^6-SCSI
ETERNUS LT20/40/60 S2 (members)Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelFUJITSU^ETERNUS^LT^S2
IBM^^^^^ULTRIUM-HH6
ETERNUS LT20/40/60 S2 (members)Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelFUJITSU^ETERNUS^LT^S2
IBM^^^^^ULTRIUM-HH7
ETERNUS LT20/40/60 S2 (members)Fibre ChannelIBMUltrium 8 Half HeightFibre ChannelFUJITSU^ETERNUS^LT^S2
IBM^^^^^ULTRIUM-HH8
ETERNUS LT20/40/60 S2 (members)SASHewlett Packard EnterpriseUltrium 920 LTO3SASFUJITSU^ETERNUS^LT^S2
HP^^^^^^Ultrium^3-SCSI
ETERNUS LT20/40/60 S2 (members)SASHewlett Packard EnterpriseUltrium 1760 LTO4SASFUJITSU^ETERNUS^LT^S2
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT20/40/60 S2 (members) [1]SASHewlett Packard EnterpriseUltrium 1840 LTO4SASFUJITSU^ETERNUS^LT^S2
HP^^^^^^Ultrium^4-SCSI
  • f132-1
ETERNUS LT20/40/60 S2 (members)SASHewlett Packard EnterpriseUltrium 3000 LTO5SASFUJITSU^ETERNUS^LT^S2
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT20/40/60 S2 (members) [1]SASHewlett Packard EnterpriseUltrium 3280 LTO5SASFUJITSU^ETERNUS^LT^S2
HP^^^^^^Ultrium^5-SCSI
  • f132-1
ETERNUS LT20/40/60 S2 (members)SASHewlett Packard EnterpriseUltrium 6250 LTO6SASFUJITSU^ETERNUS^LT^S2
HP^^^^^^Ultrium^6-SCSI
ETERNUS LT20/40/60 S2 (members)SASIBMUltrium 6 Half HeightSASFUJITSU^ETERNUS^LT^S2
IBM^^^^^ULTRIUM-HH6
ETERNUS LT20/40/60 S2 (members)SASIBMUltrium 7 Half HeightSASFUJITSU^ETERNUS^LT^S2
IBM^^^^^ULTRIUM-HH7
ETERNUS LT20/40/60 S2 (members)SASIBMUltrium 8 Half HeightSASFUJITSU^ETERNUS^LT^S2
IBM^^^^^ULTRIUM-HH8
ETERNUS LT40Fibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT40Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT40Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT40Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT40SASHewlett Packard EnterpriseUltrium 920 LTO3SASFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^3-SCSI
ETERNUS LT40SASHewlett Packard EnterpriseUltrium 1760 LTO4SASFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT40SASHewlett Packard EnterpriseUltrium 1840 LTO4SASFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT40SASHewlett Packard EnterpriseUltrium 3000 LTO5SASFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT40SASHewlett Packard EnterpriseUltrium 3280 LTO5SASFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT60Fibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT60Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT60Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT60Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT60SASHewlett Packard EnterpriseUltrium 920 LTO3SASFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^3-SCSI
ETERNUS LT60SASHewlett Packard EnterpriseUltrium 1760 LTO4SASFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT60SASHewlett Packard EnterpriseUltrium 1840 LTO4SASFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^4-SCSI
ETERNUS LT60SASHewlett Packard EnterpriseUltrium 3000 LTO5SASFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT60SASHewlett Packard EnterpriseUltrium 3280 LTO5SASFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT140Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH6
ETERNUS LT140Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH7
ETERNUS LT140Fibre ChannelIBMUltrium 8 Half HeightFibre ChannelFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH8
ETERNUS LT140SASIBMUltrium 6 Half HeightSASFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH6
ETERNUS LT140SASIBMUltrium 7 Half HeightSASFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH7
ETERNUS LT140SASIBMUltrium 8 Half HeightSASFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH8
ETERNUS LT210 (T16A2)SASIBMSystem Storage TS2230 Ultrium 3 Half HeightSASNEC^^^^^T16A2
IBM^^^^^ULT3580-HH3
ETERNUS LT210 (T16A2)SCSIIBMSystem Storage TS2230 Ultrium 3 Half HeightSCSINEC^^^^^T16A2
IBM^^^^^ULT3580-HH3
ETERNUS LT210 (T16A2)SCSIIBMUltrium 4 (U160)SCSINEC^^^^^T16A2
IBM^^^^^ULTRIUM-TD4
ETERNUS LT220 (T16A)SCSIIBMTotalStorage 3580 Ultrium 3SCSINEC^^^^^T16A
IBM^^^^^ULT3580-TD3
ETERNUS LT220 (T16A2)SCSIIBMSystem Storage TS2230 Ultrium 3 Half HeightSCSINEC^^^^^T16A2
IBM^^^^^ULT3580-HH3
ETERNUS LT220 (T16A2)SCSIIBMUltrium 4 (U160)SCSINEC^^^^^T16A2
IBM^^^^^ULTRIUM-TD4
ETERNUS LT230 (T40A)SCSIIBMTotalStorage 3580 Ultrium 3SCSINEC^^^^^T40A
IBM^^^^^ULT3580-TD3
ETERNUS LT230 (T40A2)Fibre ChannelIBMUltrium 3Fibre ChannelNEC^^^^^T40A2
IBM^^^^^ULTRIUM-TD3
ETERNUS LT230 (T40A2)Fibre ChannelIBMUltrium 4Fibre ChannelNEC^^^^^T40A2
IBM^^^^^ULTRIUM-TD4
ETERNUS LT230 (T40A2)SCSIIBMUltrium 3SCSINEC^^^^^T40A2
IBM^^^^^ULTRIUM-TD3
ETERNUS LT250Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelFUJITSU^NML7A
HP^^^^^^Ultrium^3-SCSI
ETERNUS LT250Fibre ChannelIBMSystem Storage TS2350 Ultrium 5Fibre ChannelFUJITSU^NML7A
IBM^^^^^ULT3580-TD5
ETERNUS LT250Fibre ChannelIBMUltrium 3Fibre ChannelFUJITSU^NML7A
IBM^^^^^ULTRIUM-TD3
ETERNUS LT250Fibre ChannelIBMUltrium 4Fibre ChannelFUJITSU^NML7A
IBM^^^^^ULTRIUM-TD4
ETERNUS LT250Fibre ChannelIBMUltrium 6Fibre ChannelFUJITSU^NML7A
IBM^^^^^ULTRIUM-TD6
ETERNUS LT250SCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSIFUJITSU^NML7A
HP^^^^^^Ultrium^3-SCSI
ETERNUS LT250SCSIIBMUltrium 3SCSIFUJITSU^NML7A
IBM^^^^^ULTRIUM-TD3
ETERNUS LT260Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelFUJITSU^ETERNUS^LT260
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT260Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelFUJITSU^ETERNUS^LT260
HP^^^^^^Ultrium^6-SCSI
ETERNUS LT260Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH6
ETERNUS LT260Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH7
ETERNUS LT260Fibre ChannelIBMUltrium 8 Half HeightFibre ChannelFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH8
ETERNUS LT260SASHewlett Packard EnterpriseUltrium 3000 LTO5SASFUJITSU^ETERNUS^LT260
HP^^^^^^Ultrium^5-SCSI
ETERNUS LT260SASHewlett Packard EnterpriseUltrium 6250 LTO6SASFUJITSU^ETERNUS^LT260
HP^^^^^^Ultrium^6-SCSI
ETERNUS LT260SASIBMUltrium 6 Half HeightSASFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH6
ETERNUS LT260SASIBMUltrium 7 Half HeightSASFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH7
ETERNUS LT260SASIBMUltrium 8 Half HeightSASFUJITSU^ETERNUS^LT260
IBM^^^^^ULTRIUM-HH8
ETERNUS LT270 S2Fibre ChannelHewlett Packard EnterpriseUltrium 6650 LTO6Fibre ChannelETERNUS^LT270S2
HP^^^^^^Ultrium^6-SCSI
ETERNUS LT270 S2Fibre ChannelIBMUltrium 4Fibre ChannelETERNUS^LT270S2
IBM^^^^^ULTRIUM-TD4
ETERNUS LT270 S2Fibre ChannelIBMUltrium 5Fibre ChannelETERNUS^LT270S2
IBM^^^^^ULTRIUM-TD5
ETERNUS LT270 S2Fibre ChannelIBMUltrium 6Fibre ChannelETERNUS^LT270S2
IBM^^^^^ULTRIUM-TD6
ETERNUS LT270Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelFUJITSU^NML10A
HP^^^^^^Ultrium^3-SCSI
ETERNUS LT270Fibre ChannelIBMSystem Storage TS2350 Ultrium 5Fibre ChannelFUJITSU^NML10A
IBM^^^^^ULT3580-TD5
ETERNUS LT270Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelFUJITSU^NML10A
IBM^^^^^ULT3580-TD3
ETERNUS LT270Fibre ChannelIBMUltrium 4Fibre ChannelFUJITSU^NML10A
IBM^^^^^ULTRIUM-TD4
FibreCAT TX08Fibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelFSC^^^^^FibreCAT^TX08
HP^^^^^^Ultrium^4-SCSI
FibreCAT TX08SASHewlett Packard EnterpriseUltrium 920 LTO3SASFSC^^^^^FibreCAT^TX08
HP^^^^^^Ultrium^3-SCSI
FibreCAT TX08SASHewlett Packard EnterpriseUltrium 1760 LTO4SASFSC^^^^^FibreCAT^TX08
HP^^^^^^Ultrium^4-SCSI
FibreCAT TX08SCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIFSC^^^^^FibreCAT^TX08
HP^^^^^^Ultrium^3-SCSI
FibreCAT TX24 S2Fibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^4-SCSI
FibreCAT TX24 S2SASHewlett Packard EnterpriseUltrium 920 LTO3SASFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^3-SCSI
FibreCAT TX24 S2SASHewlett Packard EnterpriseUltrium 1760 LTO4SASFSC^^^^^FibreCAT-TX24^S2
HP^^^^^^Ultrium^4-SCSI
FibreCAT TX24SCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIFSC^^^^^FibreCAT^TX24
HP^^^^^^Ultrium^3-SCSI
FibreCAT TX24SCSIIBMUltrium 3SCSIFSC^^^^^FibreCAT^TX24
IBM^^^^^ULTRIUM-TD3
FibreCAT TX48 S2Fibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^4-SCSI
FibreCAT TX48 S2SASHewlett Packard EnterpriseUltrium 920 LTO3SASFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^3-SCSI
FibreCAT TX48 S2SASHewlett Packard EnterpriseUltrium 1760 LTO4SASFSC^^^^^FibreCAT-TX48^S2
HP^^^^^^Ultrium^4-SCSI
FibreCAT TX48Fibre ChannelIBMUltrium 3Fibre ChannelFSC^^^^^FibreCAT^TX48
IBM^^^^^ULTRIUM-TD3
FibreCAT TX48Fibre ChannelIBMUltrium 4Fibre ChannelFSC^^^^^FibreCAT^TX48
IBM^^^^^ULTRIUM-TD4
FibreCAT TX48SCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIFSC^^^^^FibreCAT^TX48
HP^^^^^^Ultrium^3-SCSI
FibreCAT TX48SCSIIBMTotalStorage 3580 Ultrium 3SCSIFSC^^^^^FibreCAT^TX48
IBM^^^^^ULT3580-TD3
  1. The ETERNUS LT20 only supports half height drives. The drive referenced in this row is a full height drive.
Go to Top of "Tape Libraries with Drives"

H3C

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
CT108Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^5-SCSI
CT108Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^6-SCSI
CT108Fibre ChannelHewlett Packard EnterpriseUltrium 15000 LTO7Fibre ChannelHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^7-SCSI
CT108SASHewlett Packard EnterpriseUltrium 3000 LTO5SASHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^5-SCSI
CT108SASHewlett Packard EnterpriseUltrium 6250 LTO6SASHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^6-SCSI
CT108SASHewlett Packard EnterpriseUltrium 15000 LTO7SASHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^7-SCSI
CT224Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
CT224Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^6-SCSI
CT224Fibre ChannelHewlett Packard EnterpriseUltrium 15000 LTO7Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^7-SCSI
CT224SASHewlett Packard EnterpriseUltrium 3000 LTO5SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
CT224SASHewlett Packard EnterpriseUltrium 6250 LTO6SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^6-SCSI
CT224SASHewlett Packard EnterpriseUltrium 15000 LTO7SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^7-SCSI
CT448Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
CT448Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^6-SCSI
CT448Fibre ChannelHewlett Packard EnterpriseUltrium 15000 LTO7Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^7-SCSI
CT448SASHewlett Packard EnterpriseUltrium 3000 LTO5SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
CT448SASHewlett Packard EnterpriseUltrium 6250 LTO6SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^6-SCSI
CT448SASHewlett Packard EnterpriseUltrium 15000 LTO7SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^7-SCSI
CT7680Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelHP^^^^^^MSL6480
HP^^^^^^Ultrium^5-SCSI
CT7680Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelHP^^^^^^MSL6480
HP^^^^^^Ultrium^6-SCSI
CT7680Fibre ChannelHewlett Packard EnterpriseUltrium 15000 LTO7Fibre ChannelHP^^^^^^MSL6480
HP^^^^^^Ultrium^7-SCSI
CT7680SASHewlett Packard EnterpriseUltrium 3000 LTO5SASHP^^^^^^MSL6480
HP^^^^^^Ultrium^5-SCSI
CT7680SASHewlett Packard EnterpriseUltrium 6250 LTO6SASHP^^^^^^MSL6480
HP^^^^^^Ultrium^6-SCSI
CT7680SASHewlett Packard EnterpriseUltrium 15000 LTO7SASHP^^^^^^MSL6480
HP^^^^^^Ultrium^7-SCSI
Go to Top of "Tape Libraries with Drives"

Hewlett Packard Enterprise

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
1/8 G2 Tape AutoloaderFibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^5-SCSI
1/8 G2 Tape AutoloaderFibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^6-SCSI
1/8 G2 Tape AutoloaderFibre ChannelHewlett Packard EnterpriseUltrium 15000 LTO7Fibre ChannelHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^7-SCSI
1/8 G2 Tape AutoloaderFibre ChannelHewlett Packard EnterpriseUltrium 30750 LTO8Fibre ChannelHP^^^^^^1x8^G2^AUTOLDR
HPE^^^^^Ultrium^8-SCSI
1/8 G2 Tape AutoloaderFibre ChannelHewlett Packard EnterpriseUltrium 30750 LTO8SASHP^^^^^^1x8^G2^AUTOLDR
HPE^^^^^Ultrium^8-SCSI
1/8 G2 Tape Autoloader [1]SASHewlett Packard EnterpriseUltrium 920 LTO3SASHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^3-SCSI
  • f134-1
1/8 G2 Tape Autoloader [1]SASHewlett Packard EnterpriseUltrium 1760 LTO4SASHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^4-SCSI
  • f134-1
1/8 G2 Tape Autoloader [1]SASHewlett Packard EnterpriseUltrium 3000 LTO5SASHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^5-SCSI
  • f134-1
1/8 G2 Tape Autoloader [1]SASHewlett Packard EnterpriseUltrium 6250 LTO6SASHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^6-SCSI
  • f134-1
1/8 G2 Tape Autoloader [1]SASHewlett Packard EnterpriseUltrium 15000 LTO7SASHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^7-SCSI
  • f134-1
1/8 G2 Tape Autoloader [1]SASHewlett Packard EnterpriseUltrium 30750 LTO8SASHP^^^^^^1x8^G2^AUTOLDR
HPE^^^^^Ultrium^8-SCSI
  • f134-1
1/8 G2 Tape Autoloader [1]SCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^3-SCSI
  • f134-1
1/8 G2 Tape Autoloader [1]SCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSIHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^4-SCSI
  • f134-1
EML E-Series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelHP^^^^^^EML^E-Series
HP^^^^^^Ultrium^3-SCSI
EML E-Series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelHP^^^^^^EML^E-Series
HP^^^^^^Ultrium^4-SCSI
EML E-Series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelHP^^^^^^EML^E-Series
HP^^^^^^Ultrium^5-SCSI
EML E-Series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 6650 LTO6Fibre ChannelHP^^^^^^EML^E-Series
HP^^^^^^Ultrium^6-SCSI
ESL G3Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelHP^^^^^^ESL^G3^Series
HP^^^^^^Ultrium^4-SCSI
ESL G3Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelHP^^^^^^ESL^G3^Series
HP^^^^^^Ultrium^5-SCSI
ESL G3Fibre ChannelHewlett Packard EnterpriseUltrium 6650 LTO6Fibre ChannelHP^^^^^^ESL^G3^Series
HP^^^^^^Ultrium^6-SCSI
ESL G3Fibre ChannelHewlett Packard EnterpriseUltrium 15750 LTO7Fibre ChannelHP^^^^^^ESL^G3^Series
HP^^^^^^Ultrium^7-SCSI
MSL2024/4048/8048/8096 (G3 series) (members)Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
MSL2024/4048/8048/8096 (G3 series) (members)Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
MSL2024/4048/8048/8096 (G3 series) (members)Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
MSL2024/4048/8048/8096 (G3 series) (members)Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
MSL2024/4048/8048/8096 (G3 series) (members)Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^6-SCSI
MSL2024/4048/8048/8096 (G3 series) (members) [2]Fibre ChannelHewlett Packard EnterpriseUltrium 15000 LTO7Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^7-SCSI
  • f134-2
MSL2024/4048/8048/8096 (G3 series) (members) [3]Fibre ChannelHewlett Packard EnterpriseUltrium 30750 LTO8Fibre ChannelHP^^^^^^MSL^G3^Series
HPE^^^^^Ultrium^8-SCSI
  • f134-3
MSL2024/4048/8048/8096 (G3 series) (members)SASHewlett Packard EnterpriseUltrium 920 LTO3SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
MSL2024/4048/8048/8096 (G3 series) (members)SASHewlett Packard EnterpriseUltrium 1760 LTO4SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
MSL2024/4048/8048/8096 (G3 series) (members)SASHewlett Packard EnterpriseUltrium 3000 LTO5SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
MSL2024/4048/8048/8096 (G3 series) (members)SASHewlett Packard EnterpriseUltrium 6250 LTO6SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^6-SCSI
MSL2024/4048/8048/8096 (G3 series) (members) [2]SASHewlett Packard EnterpriseUltrium 15000 LTO7SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^7-SCSI
  • f134-2
MSL2024/4048/8048/8096 (G3 series) (members) [3]SASHewlett Packard EnterpriseUltrium 30750 LTO8SASHP^^^^^^MSL^G3^Series
HPE^^^^^Ultrium^8-SCSI
  • f134-3
MSL2024/4048/8048/8096 (G3 series) (members)SCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
MSL2024/4048/8048/8096 (G3 series) (members)SCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
MSL2024/4048/8048/8096 (G3 series) (members)SCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
MSL2024/4048/8048/8096 (G3 series) (members)SCSIHewlett Packard EnterpriseUltrium 1840 LTO4SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
MSL3040Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelHPE^MSL3040
HP^^^^^^Ultrium^6-SCSI
MSL3040Fibre ChannelHewlett Packard EnterpriseUltrium 15000 LTO7Fibre ChannelHPE^MSL3040
HP^^^^^^Ultrium^7-SCSI
MSL3040Fibre ChannelHewlett Packard EnterpriseUltrium 30750 LTO8Fibre ChannelHPE^MSL3040
HPE^^^^^Ultrium^8-SCSI
MSL3040SASHewlett Packard EnterpriseUltrium 6250 LTO6SASHPE^MSL3040
HP^^^^^^Ultrium^6-SCSI
MSL3040SASHewlett Packard EnterpriseUltrium 15000 LTO7SASHPE^MSL3040
HP^^^^^^Ultrium^7-SCSI
MSL3040SASHewlett Packard EnterpriseUltrium 30750 LTO8SASHPE^MSL3040
HPE^^^^^Ultrium^8-SCSI
MSL6480Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelHP^^^^^^MSL6480
HP^^^^^^Ultrium^5-SCSI
MSL6480Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelHP^^^^^^MSL6480
HP^^^^^^Ultrium^6-SCSI
MSL6480Fibre ChannelHewlett Packard EnterpriseUltrium 15000 LTO7Fibre ChannelHP^^^^^^MSL6480
HP^^^^^^Ultrium^7-SCSI
MSL6480Fibre ChannelHewlett Packard EnterpriseUltrium 30750 LTO8Fibre ChannelHP^^^^^^MSL6480
HPE^^^^^Ultrium^8-SCSI
MSL6480SASHewlett Packard EnterpriseUltrium 3000 LTO5SASHP^^^^^^MSL6480
HP^^^^^^Ultrium^5-SCSI
MSL6480SASHewlett Packard EnterpriseUltrium 6250 LTO6SASHP^^^^^^MSL6480
HP^^^^^^Ultrium^6-SCSI
MSL6480SASHewlett Packard EnterpriseUltrium 15000 LTO7SASHP^^^^^^MSL6480
HP^^^^^^Ultrium^7-SCSI
MSL6480SASHewlett Packard EnterpriseUltrium 30750 LTO8SASHP^^^^^^MSL6480
HPE^^^^^Ultrium^8-SCSI
  1. Minimum firmware level of 1.20 is required.
  2. LTO7 is not supported on MSL8096 & MSL8048
  3. LTO8 is not supported on MSL8096 & MSL8048
Go to Top of "Tape Libraries with Drives"

Hitachi

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
L-Series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelSTK^^^^^SL150
HP^^^^^^Ultrium^5-SCSI
L-Series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelSTK^^^^^SL150
HP^^^^^^Ultrium^6-SCSI
L-Series (members)Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH5
L-Series (members)Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH6
L-Series (members)Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH7
L-Series (members)Fibre ChannelIBMUltrium 8 Half HeightFibre ChannelSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH8
L-Series (members)SASHewlett Packard EnterpriseUltrium 3000 LTO5SASSTK^^^^^SL150
HP^^^^^^Ultrium^5-SCSI
L-Series (members)SASHewlett Packard EnterpriseUltrium 6250 LTO6SASSTK^^^^^SL150
HP^^^^^^Ultrium^6-SCSI
L-Series (members)SASIBMUltrium 5 Half HeightSASSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH5
L-Series (members)SASIBMUltrium 6 Half HeightSASSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH6
L-Series (members)SASIBMUltrium 7 Half HeightSASSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH7
L-Series (members)SASIBMUltrium 8 Half HeightSASSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH8
Go to Top of "Tape Libraries with Drives"

IBM

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
System Storage TS2900 (Machine Type 3572)SASIBMSystem Storage TS2230 Ultrium 3 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULT3580-HH3
System Storage TS2900 (Machine Type 3572)SASIBMSystem Storage TS2240 Ultrium 4 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULT3580-HH4
System Storage TS2900 (Machine Type 3572) [1]SASIBMSystem Storage TS2250 Ultrium 5 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULT3580-HH5
  • f136-1
System Storage TS2900 (Machine Type 3572)SASIBMSystem Storage TS2260 Ultrium 6 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULT3580-HH6
System Storage TS2900 (Machine Type 3572)SASIBMSystem Storage TS2270 Ultrium 7 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULT3580-HH7
System Storage TS2900 (Machine Type 3572)SASIBMSystem Storage TS2280 Ultrium 8 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULT3580-HH8
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]Fibre ChannelIBMSystem Storage TS2240 Ultrium 4 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH4
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]Fibre ChannelIBMSystem Storage TS2250 Ultrium 5 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH5
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]Fibre ChannelIBMSystem Storage TS2260 Ultrium 6 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH6
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]Fibre ChannelIBMSystem Storage TS2270 Ultrium 7 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH7
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]Fibre ChannelIBMSystem Storage TS2280 Ultrium 8 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH8
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]Fibre ChannelIBMSystem Storage TS2340 Ultrium 4Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD4
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]Fibre ChannelIBMSystem Storage TS2350 Ultrium 5Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD5
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]Fibre ChannelIBMSystem Storage TS2360 Ultrium 6Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD6
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD3
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]SASIBMSystem Storage TS2230 Ultrium 3 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH3
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]SASIBMSystem Storage TS2240 Ultrium 4 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH4
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]SASIBMSystem Storage TS2250 Ultrium 5 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH5
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]SASIBMSystem Storage TS2260 Ultrium 6 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH6
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]SASIBMSystem Storage TS2270 Ultrium 7 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH7
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]SASIBMSystem Storage TS2280 Ultrium 8 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH8
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]SASIBMSystem Storage TS2340 Ultrium 4SASIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD4
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]SASIBMSystem Storage TS2350 Ultrium 5SASIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD5
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]SCSIIBMSystem Storage TS2230 Ultrium 3 Half HeightSCSIIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH3
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]SCSIIBMSystem Storage TS2340 Ultrium 4SCSIIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD4
  • f136-2
System Storage TS3100/TS3200 (Machine Type 3573) (members) [2]SCSIIBMTotalStorage 3580 Ultrium 3SCSIIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD3
  • f136-2
System Storage TS3310 (Machine Type 3576) [3]Fibre ChannelIBMSystem Storage TS2340 Ultrium 4Fibre ChannelIBM^^^^^3576-MTL
IBM^^^^^ULT3580-TD4
  • f136-3
System Storage TS3310 (Machine Type 3576) [4]Fibre ChannelIBMSystem Storage TS2350 Ultrium 5Fibre ChannelIBM^^^^^3576-MTL
IBM^^^^^ULT3580-TD5
  • f136-4
System Storage TS3310 (Machine Type 3576)Fibre ChannelIBMSystem Storage TS2360 Ultrium 6Fibre ChannelIBM^^^^^3576-MTL
IBM^^^^^ULT3580-TD6
System Storage TS3310 (Machine Type 3576)Fibre ChannelIBMSystem Storage TS2370 Ultrium 7Fibre ChannelIBM^^^^^3576-MTL
IBM^^^^^ULT3580-TD7
System Storage TS3310 (Machine Type 3576)Fibre ChannelIBMSystem Storage TS2380 Ultrium 8Fibre ChannelIBM^^^^^3576-MTL
IBM^^^^^ULT3580-TD8
System Storage TS3310 (Machine Type 3576)Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelIBM^^^^^3576-MTL
IBM^^^^^ULT3580-TD3
System Storage TS3310 (Machine Type 3576) [3]SASIBMSystem Storage TS2340 Ultrium 4SASIBM^^^^^3576-MTL
IBM^^^^^ULT3580-TD4
  • f136-3
System Storage TS3310 (Machine Type 3576)SCSIIBMTotalStorage 3580 Ultrium 3SCSIIBM^^^^^3576-MTL
IBM^^^^^ULT3580-TD3
System Storage TS3500 (Machine Type 3584)Fibre ChannelIBMSystem Storage TS1030 (3588 Model F3B) Ultrium 3Fibre ChannelIBM^^^^^03584
IBM^^^^^ULT3580-TD3
System Storage TS3500 (Machine Type 3584) [5][6][7]Fibre ChannelIBMSystem Storage TS1140 (3592 Model E07)Fibre ChannelIBM^^^^^03584
IBM^^^^^03592E07
  • f136-5
  • f136-6
  • f136-7
System Storage TS3500 (Machine Type 3584) [5][6][8]Fibre ChannelIBMSystem Storage TS1150 (3592 Model E08)Fibre ChannelIBM^^^^^03584
IBM^^^^^03592E08
  • f136-5
  • f136-6
  • f136-8
System Storage TS3500 (Machine Type 3584)Fibre ChannelIBMSystem Storage TS2340 Ultrium 4Fibre ChannelIBM^^^^^03584
IBM^^^^^ULT3580-TD4
System Storage TS3500 (Machine Type 3584) [6]Fibre ChannelIBMSystem Storage TS2350 Ultrium 5Fibre ChannelIBM^^^^^03584
IBM^^^^^ULT3580-TD5
  • f136-6
System Storage TS3500 (Machine Type 3584) [6]Fibre ChannelIBMSystem Storage TS2360 Ultrium 6Fibre ChannelIBM^^^^^03584
IBM^^^^^ULT3580-TD6
  • f136-6
System Storage TS3500 (Machine Type 3584) [6]Fibre ChannelIBMSystem Storage TS2370 Ultrium 7Fibre ChannelIBM^^^^^03584
IBM^^^^^ULT3580-TD7
  • f136-6
System Storage TS3500 (Machine Type 3584)Fibre ChannelIBMSystem Storage TS2380 Ultrium 8Fibre ChannelIBM^^^^^03584
IBM^^^^^ULT3580-TD8
System Storage TS3500 (Machine Type 3584)Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelIBM^^^^^03584
IBM^^^^^ULT3580-TD3
System Storage TS4300 (Machine Type 3555)Fibre ChannelIBMSystem Storage TS2260 Ultrium 6 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH6
System Storage TS4300 (Machine Type 3555)Fibre ChannelIBMSystem Storage TS2270 Ultrium 7 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH7
System Storage TS4300 (Machine Type 3555)Fibre ChannelIBMSystem Storage TS2280 Ultrium 8 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH8
System Storage TS4300 (Machine Type 3555)Fibre ChannelIBMSystem Storage TS2360 Ultrium 6Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD6
System Storage TS4300 (Machine Type 3555)Fibre ChannelIBMSystem Storage TS2370 Ultrium 7Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD7
System Storage TS4300 (Machine Type 3555)Fibre ChannelIBMSystem Storage TS2380 Ultrium 8Fibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULT3580-TD8
System Storage TS4300 (Machine Type 3555)SASIBMSystem Storage TS2260 Ultrium 6 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH6
System Storage TS4300 (Machine Type 3555)SASIBMSystem Storage TS2270 Ultrium 7 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH7
System Storage TS4300 (Machine Type 3555)SASIBMSystem Storage TS2280 Ultrium 8 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULT3580-HH8
  1. Minimum firmware levels of 0018 are required for the library and B171 for the drive.
  2. IBM markets this under two names, with and without the words "Express Model". They are identical and both are supported.
  3. L1 barcode labels on a cleaning media will cause a cleaning utility job to hang indefinitely. Recommend using L2 (or above) barcode labels for cleaning media.
  4. L1 and L2 barcode labels on a cleaning media will cause a cleaning utility job to hang indefinitely. Recommend using L3 (or above) barcode labels for cleaning media.
  5. Capacity and compression reporting is not currently supported for this device.
  6. Due to IBM ALMS virtualizing the tape slots: the tapes are not in the slot order as they appear in the BE GUI and the cleaning tapes are not visible to BE. Therefore drive cleaning must be done via the library itself.
  7. For optimal performance, do not mix generations of 3592 drives in a single logical library. Media problems can result when different drive generations are mixed. Please see http://www-01.ibm.com/support/docview.wss?uid=swg21570099
  8. For optimal performance, do not mix generations of 3592 drives in a single logical library. Media problems can result when different drive generations are mixed. Please see http://www-01.ibm.com/support/docview.wss?uid=swg21687064
Go to Top of "Tape Libraries with Drives"

Imation

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
L1200 LTO 2U Tape LibraryFibre ChannelIBMUltrium 4 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH4
L1200 LTO 2U Tape LibraryFibre ChannelIBMUltrium 5 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH5
L1200 LTO 2U Tape LibrarySASIBMUltrium 4 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH4
L1200 LTO 2U Tape LibrarySASIBMUltrium 5 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH5
L1400 LTO 4U Tape LibraryFibre ChannelIBMUltrium 4 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH4
L1400 LTO 4U Tape LibraryFibre ChannelIBMUltrium 5 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH5
L1400 LTO 4U Tape LibrarySASIBMUltrium 4 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH4
L1400 LTO 4U Tape LibrarySASIBMUltrium 5 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH5
Go to Top of "Tape Libraries with Drives"

NEC

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
LL009FSASIBMSystem Storage TS2250 Ultrium 5 Half HeightSASNEC^^^^^LL009F
IBM^^^^^ULT3580-HH5
LL009F [1]SASIBMUltrium 3 Half HeightSASNEC^^^^^LL009F
IBM^^^^^ULTRIUM-HH3
  • f138-1
LL009F [1]SASIBMUltrium 4 Half HeightSASNEC^^^^^LL009F
IBM^^^^^ULTRIUM-HH4
  • f138-1
LL009FSASIBMUltrium 6 Half HeightSASNEC^^^^^LL009F
IBM^^^^^ULTRIUM-HH6
LL009FSASIBMUltrium 7 Half HeightSASNEC^^^^^LL009F
IBM^^^^^ULTRIUM-HH7
LL009FSASIBMUltrium 8 Half HeightSASNEC^^^^^LL009F
IBM^^^^^ULTRIUM-HH8
T16A2SASIBMSystem Storage TS2240 Ultrium 4 Half HeightSASNEC^^^^^T16A2
IBM^^^^^ULT3580-HH4
T16A2SASIBMSystem Storage TS2350 Ultrium 5SASNEC^^^^^T16A2
IBM^^^^^ULT3580-TD5
T16A2SCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSINEC^^^^^T16A2
HP^^^^^^Ultrium^3-SCSI
T16A2SCSIIBMSystem Storage TS2230 Ultrium 3 Half HeightSCSINEC^^^^^T16A2
IBM^^^^^ULT3580-HH3
T16A2SCSIIBMUltrium 4 (U160)SCSINEC^^^^^T16A2
IBM^^^^^ULTRIUM-TD4
T30A/T60A (members)Fibre ChannelIBMUltrium 4 Half HeightFibre ChannelNEC^^^^^LL-2B01
IBM^^^^^ULTRIUM-HH4
T30A/T60A (members)Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelNEC^^^^^LL-2B01
IBM^^^^^ULTRIUM-HH5
T30A/T60A (members)Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelNEC^^^^^LL-2B01
IBM^^^^^ULTRIUM-HH6
T30A/T60A (members)Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelNEC^^^^^LL-2B01
IBM^^^^^ULTRIUM-HH7
T30A/T60A (members)SASIBMUltrium 3 Half HeightSASNEC^^^^^LL-2B01
IBM^^^^^ULTRIUM-HH3
T30A/T60A (members)SASIBMUltrium 4 Half HeightSASNEC^^^^^LL-2B01
IBM^^^^^ULTRIUM-HH4
T30A/T60A (members)SASIBMUltrium 5 Half HeightSASNEC^^^^^LL-2B01
IBM^^^^^ULTRIUM-HH5
T30A/T60A (members)SASIBMUltrium 6 Half HeightSASNEC^^^^^LL-2B01
IBM^^^^^ULTRIUM-HH6
T30A/T60A (members)SASIBMUltrium 7 Half HeightSASNEC^^^^^LL-2B01
IBM^^^^^ULTRIUM-HH7
T40A2Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelNEC^^^^^T40A2
HP^^^^^^Ultrium^3-SCSI
T40A2Fibre ChannelIBMSystem Storage TS2350 Ultrium 5Fibre ChannelNEC^^^^^T40A2
IBM^^^^^ULT3580-TD5
T40A2Fibre ChannelIBMUltrium 3Fibre ChannelNEC^^^^^T40A2
IBM^^^^^ULTRIUM-TD3
T40A2Fibre ChannelIBMUltrium 4Fibre ChannelNEC^^^^^T40A2
IBM^^^^^ULTRIUM-TD4
T40A2SASIBMSystem Storage TS2350 Ultrium 5SASNEC^^^^^T40A2
IBM^^^^^ULT3580-TD5
T40A2SASIBMUltrium 4SASNEC^^^^^T40A2
IBM^^^^^ULTRIUM-TD4
T40A2SCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSINEC^^^^^T40A2
HP^^^^^^Ultrium^3-SCSI
T40A2SCSIIBMUltrium 3SCSINEC^^^^^T40A2
IBM^^^^^ULTRIUM-TD3
T100AFibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelFUJITSU^NML7A
HP^^^^^^Ultrium^3-SCSI
T100AFibre ChannelIBMUltrium 4Fibre ChannelFUJITSU^NML7A
IBM^^^^^ULTRIUM-TD4
T100ASCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSIFUJITSU^NML7A
HP^^^^^^Ultrium^3-SCSI
T100A2Fibre ChannelIBMUltrium 5Fibre ChannelFUJITSU^NML7A
IBM^^^^^ULTRIUM-TD5
T100A2Fibre ChannelIBMUltrium 6Fibre ChannelFUJITSU^NML7A
IBM^^^^^ULTRIUM-TD6
T280 (Machine Type 3555)Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH7
T280 (Machine Type 3555)Fibre ChannelIBMUltrium 8 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH8
T280 (Machine Type 3555)SASIBMUltrium 7 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH7
T280 (Machine Type 3555)SASIBMUltrium 8 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH8
T700AFibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelFUJITSU^NML10A
HP^^^^^^Ultrium^3-SCSI
T700AFibre ChannelIBMUltrium 4Fibre ChannelFUJITSU^NML10A
IBM^^^^^ULTRIUM-TD4
T700A2Fibre ChannelIBMUltrium 5Fibre ChannelETERNUS^LT270S2
IBM^^^^^ULTRIUM-TD5
T700A2Fibre ChannelIBMUltrium 6Fibre ChannelETERNUS^LT270S2
IBM^^^^^ULTRIUM-TD6
  1. T10 Hardware Encryption is supported with library firmware 0002 and above.
Go to Top of "Tape Libraries with Drives"

Oracle

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
StorageTek SL150Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelSTK^^^^^SL150
HP^^^^^^Ultrium^5-SCSI
StorageTek SL150Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelSTK^^^^^SL150
HP^^^^^^Ultrium^6-SCSI
StorageTek SL150Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH5
StorageTek SL150Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH6
StorageTek SL150Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH7
StorageTek SL150Fibre ChannelIBMUltrium 8 Half HeightFibre ChannelSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH8
StorageTek SL150SASHewlett Packard EnterpriseUltrium 3000 LTO5SASSTK^^^^^SL150
HP^^^^^^Ultrium^5-SCSI
StorageTek SL150SASHewlett Packard EnterpriseUltrium 6250 LTO6SASSTK^^^^^SL150
HP^^^^^^Ultrium^6-SCSI
StorageTek SL150SASIBMUltrium 5 Half HeightSASSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH5
StorageTek SL150SASIBMUltrium 6 Half HeightSASSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH6
StorageTek SL150SASIBMUltrium 7 Half HeightSASSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH7
StorageTek SL150SASIBMUltrium 8 Half HeightSASSTK^^^^^SL150
IBM^^^^^ULTRIUM-HH8
StorageTek SL500Fibre ChannelHewlett Packard EnterpriseUltrium 6650 LTO6Fibre ChannelSTK^^^^^SL500
HP^^^^^^Ultrium^6-SCSI
StorageTek SL3000Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelSTK^^^^^SL3000
HP^^^^^^Ultrium^4-SCSI
StorageTek SL3000Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelSTK^^^^^SL3000
HP^^^^^^Ultrium^5-SCSI
StorageTek SL3000Fibre ChannelHewlett Packard EnterpriseUltrium 6650 LTO6Fibre ChannelSTK^^^^^SL3000
HP^^^^^^Ultrium^6-SCSI
StorageTek SL3000Fibre ChannelIBMSystem Storage TS2350 Ultrium 5Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULT3580-TD5
StorageTek SL3000Fibre ChannelIBMUltrium 4Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULTRIUM-TD4
StorageTek SL3000Fibre ChannelIBMUltrium 5Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULTRIUM-TD5
StorageTek SL3000Fibre ChannelIBMUltrium 6Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULTRIUM-TD6
StorageTek SL3000Fibre ChannelIBMUltrium 7Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULTRIUM-TD7
StorageTek SL3000Fibre ChannelIBMUltrium 8Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULTRIUM-TD8
StorageTek SL3000Fibre ChannelOracleStorageTek T9840DFibre ChannelSTK^^^^^SL3000
STK^^^^^T9840D
StorageTek SL3000Fibre ChannelOracleStorageTek T10000AFibre ChannelSTK^^^^^SL3000
STK^^^^^T10000A
StorageTek SL3000Fibre ChannelOracleStorageTek T10000BFibre ChannelSTK^^^^^SL3000
STK^^^^^T10000B
StorageTek SL3000Fibre ChannelOracleStorageTek T10000CFibre ChannelSTK^^^^^SL3000
STK^^^^^T10000C
StorageTek SL3000Fibre ChannelOracleStorageTek T10000DFibre ChannelSTK^^^^^SL3000
STK^^^^^T10000D
StorageTek SL3000Fibre ChannelOracleT9840CFibre ChannelSTK^^^^^SL3000
STK^^^^^T9840C
StorageTek SL4000Fibre ChannelIBMUltrium 7Fibre ChannelSTK^^^^^SL4000
IBM^^^^^ULTRIUM-TD7
StorageTek SL4000Fibre ChannelIBMUltrium 8Fibre ChannelSTK^^^^^SL4000
IBM^^^^^ULTRIUM-TD8
Go to Top of "Tape Libraries with Drives"

Overland Storage

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
NEO 100s 2nd GenerationSASIBMUltrium 5 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULTRIUM-HH5
NEO 100s 2nd GenerationSASIBMUltrium 6 Half HeightSASIBM^^^^^3572-TL
IBM^^^^^ULTRIUM-HH6
NEO E-Series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelOVERLANDNEO^Series
HP^^^^^^Ultrium^4-SCSI
NEO E-Series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelOVERLANDNEO^Series
HP^^^^^^Ultrium^5-SCSI
NEO E-Series (members)Fibre ChannelIBMUltrium 4Fibre ChannelOVERLANDNEO^Series
IBM^^^^^ULTRIUM-TD4
NEO E-Series (members)Fibre ChannelIBMUltrium 5Fibre ChannelOVERLANDNEO^Series
IBM^^^^^ULTRIUM-TD5
NEO E-Series (members)Fibre ChannelIBMUltrium 6Fibre ChannelOVERLANDNEO^Series
IBM^^^^^ULTRIUM-TD6
NEO E-Series (members)Fibre ChannelIBMUltrium 7Fibre ChannelOVERLANDNEO^Series
IBM^^^^^ULTRIUM-TD7
NEO E-Series (members)SASHewlett Packard EnterpriseUltrium 1840 LTO4SASOVERLANDNEO^Series
HP^^^^^^Ultrium^4-SCSI
NEO E-Series (members)SASHewlett Packard EnterpriseUltrium 3000 LTO5SASOVERLANDNEO^Series
HP^^^^^^Ultrium^5-SCSI
NEO E-Series (members)SASHewlett Packard EnterpriseUltrium 3280 LTO5SASOVERLANDNEO^Series
HP^^^^^^Ultrium^5-SCSI
NEO E-Series (members)SASIBMUltrium 4SASOVERLANDNEO^Series
IBM^^^^^ULTRIUM-TD4
NEO E-Series (members)SASIBMUltrium 5SASOVERLANDNEO^Series
IBM^^^^^ULTRIUM-TD5
NEO E-Series (members)SASIBMUltrium 6SASOVERLANDNEO^Series
IBM^^^^^ULTRIUM-TD6
NEO E-Series (members)SCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSIOVERLANDNEO^Series
HP^^^^^^Ultrium^3-SCSI
NEO E-Series (members)SCSIHewlett Packard EnterpriseUltrium 1840 LTO4SCSIOVERLANDNEO^Series
HP^^^^^^Ultrium^4-SCSI
NEO E-Series (members)SCSIIBMUltrium 4 (U320)SCSIOVERLANDNEO^Series
IBM^^^^^ULTRIUM-TD4
NEOs series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
NEOs series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
NEOs series (members)SASHewlett Packard EnterpriseUltrium 920 LTO3SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
NEOs series (members)SASHewlett Packard EnterpriseUltrium 1760 LTO4SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
NEOs series (members)SASHewlett Packard EnterpriseUltrium 3000 LTO5SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
NEOs series (members)SCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
NEOs series (members)SCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
NEOs series 2nd Generation (members)Fibre ChannelIBMUltrium 4 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH4
NEOs series 2nd Generation (members)Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH5
NEOs series 2nd Generation (members)Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH6
NEOs series 2nd Generation (members)SASIBMUltrium 4 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH4
NEOs series 2nd Generation (members)SASIBMUltrium 5 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH5
NEOs series 2nd Generation (members)SASIBMUltrium 6 Half HeightSASIBM^^^^^3573-TL
IBM^^^^^ULTRIUM-HH6
NEOs series 3rd Generation (members)Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH5
NEOs series 3rd Generation (members)Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH6
NEOs series 3rd Generation (members)Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH7
NEOs series 3rd Generation (members)Fibre ChannelIBMUltrium 8 Half HeightFibre ChannelBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH8
NEOs series 3rd Generation (members)SASIBMUltrium 5 Half HeightSASBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH5
NEOs series 3rd Generation (members)SASIBMUltrium 6 Half HeightSASBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH6
NEOs series 3rd Generation (members)SASIBMUltrium 7 Half HeightSASBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH7
NEOs series 3rd Generation (members)SASIBMUltrium 8 Half HeightSASBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH8
NEOxl series (members)Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH5
NEOxl series (members)Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH6
NEOxl series (members)Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH7
NEOxl series (members)Fibre ChannelIBMUltrium 8 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH8
NEOxl series (members)SASIBMUltrium 5 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH5
NEOxl series (members)SASIBMUltrium 6 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH6
NEOxl series (members)SASIBMUltrium 7 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH7
NEOxl series (members)SASIBMUltrium 8 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH8
Go to Top of "Tape Libraries with Drives"

PivotStor

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
AP TL2000 2USASHewlett Packard EnterpriseUltrium 1760 LTO4SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
AP TL2000 2USCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
AP TL4000 4USASHewlett Packard EnterpriseUltrium 1760 LTO4SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
AP TL4000 4USCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
AP TL8000 8USASHewlett Packard EnterpriseUltrium 1760 LTO4SASBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
AP TL8000 8USCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^4-SCSI
Go to Top of "Tape Libraries with Drives"

Qualstar

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
Q24/Q48 (members)Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH6
Q24/Q48 (members)Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH7
Q24/Q48 (members)SASIBMUltrium 6 Half HeightSASBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH6
Q24/Q48 (members)SASIBMUltrium 7 Half HeightSASBDT^^^^^FlexStor^II
IBM^^^^^ULTRIUM-HH7
Q80Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH6
Q80Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH7
Q80SASIBMUltrium 6 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH6
Q80SASIBMUltrium 7 Half HeightSASBDT^^^^^MULTISTAK
IBM^^^^^ULTRIUM-HH7
RLS-8000 LTO series (members)Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelQUALSTARRLS-8
IBM^^^^^ULTRIUM-HH5
RLS-8000 LTO series (members)SASIBMUltrium 5 Half HeightSASQUALSTARRLS-8
IBM^^^^^ULTRIUM-HH5
RLS-8000 LTO series (members)SCSIIBMTotalStorage 3580 Ultrium 3SCSIQUALSTARRLS-8
IBM^^^^^ULT3580-TD3
RLS-8000D LTO series (members)Fibre ChannelIBMUltrium 4Fibre ChannelQUALSTARRLS-8
IBM^^^^^ULTRIUM-TD4
RLS-8000D LTO series (members)Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelQUALSTARRLS-8
IBM^^^^^ULTRIUM-HH5
RLS-8000D LTO series (members)Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelQUALSTARRLS-8
IBM^^^^^ULTRIUM-HH6
RLS-8000D LTO series (members)SASIBMUltrium 5 Half HeightSASQUALSTARRLS-8
IBM^^^^^ULTRIUM-HH5
RLS-8500 LTO series (members)Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelQUALSTARRLS-85
IBM^^^^^ULTRIUM-HH5
RLS-8500 LTO series (members)Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelQUALSTARRLS-85
IBM^^^^^ULTRIUM-HH6
RLS-8500 LTO series (members)Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelQUALSTARRLS-85
IBM^^^^^ULTRIUM-HH7
RLS-8500 LTO series (members)SASIBMUltrium 5 Half HeightSASQUALSTARRLS-85
IBM^^^^^ULTRIUM-HH5
RLS-8500 LTO series (members)SASIBMUltrium 6 Half HeightSASQUALSTARRLS-85
IBM^^^^^ULTRIUM-HH6
RLS-8500 LTO series (members)SASIBMUltrium 7 Half HeightSASQUALSTARRLS-85
IBM^^^^^ULTRIUM-HH7
TLS-5000 SAIT series (members)SCSIIBMUltrium 4 (U320)SCSIQUALSTARTLS-5
IBM^^^^^ULTRIUM-TD4
TLS-5000 SAIT series (members)SCSIIBMUltrium 4Fibre ChannelQUALSTARTLS-5
IBM^^^^^ULTRIUM-TD4
TLS-8000 LTO series (members)Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelQUALSTARTLS-8
IBM^^^^^ULT3580-TD3
TLS-8000 LTO series (members)Fibre ChannelIBMUltrium 4Fibre ChannelQUALSTARTLS-8
IBM^^^^^ULTRIUM-TD4
TLS-8000 LTO series (members)Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelQUALSTARTLS-8
IBM^^^^^ULTRIUM-HH5
TLS-8000 LTO series (members)Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelQUALSTARTLS-8
IBM^^^^^ULTRIUM-HH6
TLS-8000 LTO series (members)SASIBMUltrium 5 Half HeightSASQUALSTARTLS-8
IBM^^^^^ULTRIUM-HH5
TLS-8000 LTO series (members)SASIBMUltrium 6 Half HeightSASQUALSTARTLS-8
IBM^^^^^ULTRIUM-HH6
TLS-8000 LTO series (members)SCSIIBMTotalStorage 3580 Ultrium 3SCSIQUALSTARTLS-8
IBM^^^^^ULT3580-TD3
TLS-8000 LTO series (members)SCSIIBMUltrium 3Fibre ChannelQUALSTARTLS-8
IBM^^^^^ULTRIUM-TD3
TLS-8000 LTO series (members)SCSIIBMUltrium 4 (U160)SCSIQUALSTARTLS-8
IBM^^^^^ULTRIUM-TD4
XLS-8000SCSIIBMTotalStorage 3580 Ultrium 3SCSIQUALSTARXLS-8000
IBM^^^^^ULT3580-TD3
XLS series (members)Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelQUALSTARXLS-8000
IBM^^^^^ULT3580-TD3
XLS series (members)Fibre ChannelIBMUltrium 3Fibre ChannelQUALSTARXLS-8000
IBM^^^^^ULTRIUM-TD3
XLS series (members)Fibre ChannelIBMUltrium 4Fibre ChannelQUALSTARXLS-8000
IBM^^^^^ULTRIUM-TD4
XLS series (members)Fibre ChannelIBMUltrium 5Fibre ChannelQUALSTARXLS-8000
IBM^^^^^ULTRIUM-TD5
XLS series (members)Fibre ChannelIBMUltrium 6Fibre ChannelQUALSTARXLS-8000
IBM^^^^^ULTRIUM-TD6
XLS series (members)Fibre ChannelIBMUltrium 7Fibre ChannelQUALSTARXLS-8000
IBM^^^^^ULTRIUM-TD7
Go to Top of "Tape Libraries with Drives"

Quantum

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
Scalar i3Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelQUANTUM^Scalar^i3-i6
IBM^^^^^ULTRIUM-HH6
Scalar i3Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelQUANTUM^Scalar^i3-i6
IBM^^^^^ULTRIUM-HH7
Scalar i3Fibre ChannelIBMUltrium 8 Half HeightFibre ChannelQUANTUM^Scalar^i3-i6
IBM^^^^^ULTRIUM-HH8
Scalar i3SASIBMUltrium 6 Half HeightSASQUANTUM^Scalar^i3-i6
IBM^^^^^ULTRIUM-HH6
Scalar i3SASIBMUltrium 7 Half HeightSASQUANTUM^Scalar^i3-i6
IBM^^^^^ULTRIUM-HH7
Scalar i3SASIBMUltrium 8 Half HeightSASQUANTUM^Scalar^i3-i6
IBM^^^^^ULTRIUM-HH8
Scalar i6Fibre ChannelIBMUltrium 6Fibre ChannelQUANTUM^Scalar^i3-i6
IBM^^^^^ULTRIUM-TD6
Scalar i6Fibre ChannelIBMUltrium 7Fibre ChannelQUANTUM^Scalar^i3-i6
IBM^^^^^ULTRIUM-TD7
Scalar i6Fibre ChannelIBMUltrium 8Fibre ChannelQUANTUM^Scalar^i3-i6
IBM^^^^^ULTRIUM-TD8
Scalar i40/i80 series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelQUANTUM^Scalar^i40-i80
HP^^^^^^Ultrium^4-SCSI
Scalar i40/i80 series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelQUANTUM^Scalar^i40-i80
HP^^^^^^Ultrium^4-SCSI
Scalar i40/i80 series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelQUANTUM^Scalar^i40-i80
HP^^^^^^Ultrium^5-SCSI
Scalar i40/i80 series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelQUANTUM^Scalar^i40-i80
HP^^^^^^Ultrium^6-SCSI
Scalar i40/i80 series (members)Fibre ChannelIBMUltrium 5 Half HeightFibre ChannelQUANTUM^Scalar^i40-i80
IBM^^^^^ULTRIUM-HH5
Scalar i40/i80 series (members)Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelQUANTUM^Scalar^i40-i80
IBM^^^^^ULTRIUM-HH6
Scalar i40/i80 series (members)Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelQUANTUM^Scalar^i40-i80
IBM^^^^^ULTRIUM-HH7
Scalar i40/i80 series (members)SASHewlett Packard EnterpriseUltrium 1760 LTO4SASQUANTUM^Scalar^i40-i80
HP^^^^^^Ultrium^4-SCSI
Scalar i40/i80 series (members)SASHewlett Packard EnterpriseUltrium 1840 LTO4SASQUANTUM^Scalar^i40-i80
HP^^^^^^Ultrium^4-SCSI
Scalar i40/i80 series (members)SASHewlett Packard EnterpriseUltrium 3000 LTO5SASQUANTUM^Scalar^i40-i80
HP^^^^^^Ultrium^5-SCSI
Scalar i40/i80 series (members)SASHewlett Packard EnterpriseUltrium 6250 LTO6SASQUANTUM^Scalar^i40-i80
HP^^^^^^Ultrium^6-SCSI
Scalar i40/i80 series (members)SASIBMUltrium 5 Half HeightSASQUANTUM^Scalar^i40-i80
IBM^^^^^ULTRIUM-HH5
Scalar i40/i80 series (members)SASIBMUltrium 6 Half HeightSASQUANTUM^Scalar^i40-i80
IBM^^^^^ULTRIUM-HH6
Scalar i40/i80 series (members)SASIBMUltrium 7 Half HeightSASQUANTUM^Scalar^i40-i80
IBM^^^^^ULTRIUM-HH7
Scalar i500Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelQuantum^Scalar^i500
HP^^^^^^Ultrium^4-SCSI
Scalar i500 [1]Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelQuantum^Scalar^i500
HP^^^^^^Ultrium^5-SCSI
  • f143-1
Scalar i500Fibre ChannelHewlett Packard EnterpriseUltrium 6650 LTO6Fibre ChannelQuantum^Scalar^i500
HP^^^^^^Ultrium^6-SCSI
Scalar i500Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelQuantum^Scalar^i500
IBM^^^^^ULT3580-TD3
Scalar i500 [2]Fibre ChannelIBMUltrium 4Fibre ChannelQuantum^Scalar^i500
IBM^^^^^ULTRIUM-TD4
  • f143-2
Scalar i500Fibre ChannelIBMUltrium 5Fibre ChannelQuantum^Scalar^i500
IBM^^^^^ULTRIUM-TD5
Scalar i500Fibre ChannelIBMUltrium 6Fibre ChannelQuantum^Scalar^i500
IBM^^^^^ULTRIUM-TD6
Scalar i500Fibre ChannelIBMUltrium 7Fibre ChannelQuantum^Scalar^i500
IBM^^^^^ULTRIUM-TD7
Scalar i500Fibre ChannelIBMUltrium 8Fibre ChannelQuantum^Scalar^i500
IBM^^^^^ULTRIUM-TD8
Scalar i500 [2]SASHewlett Packard EnterpriseUltrium 1840 LTO4SASQuantum^Scalar^i500
HP^^^^^^Ultrium^4-SCSI
  • f143-2
Scalar i500 [1]SASHewlett Packard EnterpriseUltrium 3280 LTO5SASQuantum^Scalar^i500
HP^^^^^^Ultrium^5-SCSI
  • f143-1
Scalar i500SASHewlett Packard EnterpriseUltrium 6650 LTO6SASQuantum^Scalar^i500
HP^^^^^^Ultrium^6-SCSI
Scalar i500 [1]SASIBMSystem Storage TS2350 Ultrium 5SASQuantum^Scalar^i500
IBM^^^^^ULT3580-TD5
  • f143-1
Scalar i500 [2]SASIBMUltrium 4SASQuantum^Scalar^i500
IBM^^^^^ULTRIUM-TD4
  • f143-2
Scalar i6000 [3]Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelQuantum^Scalar^i6000
HP^^^^^^Ultrium^3-SCSI
  • f143-3
Scalar i6000 [2][3]Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelQuantum^Scalar^i6000
HP^^^^^^Ultrium^4-SCSI
  • f143-2
  • f143-3
Scalar i6000 [1][3]Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelQuantum^Scalar^i6000
HP^^^^^^Ultrium^5-SCSI
  • f143-1
  • f143-3
Scalar i6000 [3]Fibre ChannelHewlett Packard EnterpriseUltrium 6650 LTO6Fibre ChannelQuantum^Scalar^i6000
HP^^^^^^Ultrium^6-SCSI
  • f143-3
Scalar i6000 [3]Fibre ChannelIBMUltrium 3Fibre ChannelQuantum^Scalar^i6000
IBM^^^^^ULTRIUM-TD3
  • f143-3
Scalar i6000 [3]Fibre ChannelIBMUltrium 4Fibre ChannelQuantum^Scalar^i6000
IBM^^^^^ULTRIUM-TD4
  • f143-3
Scalar i6000 [3]Fibre ChannelIBMUltrium 5Fibre ChannelQuantum^Scalar^i6000
IBM^^^^^ULTRIUM-TD5
  • f143-3
Scalar i6000 [3]Fibre ChannelIBMUltrium 6Fibre ChannelQuantum^Scalar^i6000
IBM^^^^^ULTRIUM-TD6
  • f143-3
Scalar i6000 [3]Fibre ChannelIBMUltrium 7Fibre ChannelQuantum^Scalar^i6000
IBM^^^^^ULTRIUM-TD7
  • f143-3
Scalar i6000 [3]Fibre ChannelIBMUltrium 8Fibre ChannelQuantum^Scalar^i6000
IBM^^^^^ULTRIUM-TD8
  • f143-3
SuperLoader 3SASIBMUltrium 4 Half HeightSASQUANTUM^UHDL
IBM^^^^^ULTRIUM-HH4
SuperLoader 3SASIBMUltrium 5 Half HeightSASQUANTUM^UHDL
IBM^^^^^ULTRIUM-HH5
SuperLoader 3SASIBMUltrium 6 Half HeightSASQUANTUM^UHDL
IBM^^^^^ULTRIUM-HH6
SuperLoader 3SASIBMUltrium 7 Half HeightSASQUANTUM^UHDL
IBM^^^^^ULTRIUM-HH7
SuperLoader 3SASIBMUltrium 8 Half HeightSASQUANTUM^UHDL
IBM^^^^^ULTRIUM-HH8
SuperLoader 3SASQuantumLTO-3 HHSASQUANTUM^UHDL
QUANTUM^ULTRIUM^3
SuperLoader 3SASQuantumLTO-4 HHSASQUANTUM^UHDL
QUANTUM^ULTRIUM^4
SuperLoader 3SASQuantumLTO-5 FHSASQUANTUM^UHDL
QUANTUM^ULTRIUM^5
SuperLoader 3SASQuantumLTO-5 HHSASQUANTUM^UHDL
QUANTUM^ULTRIUM^5
SuperLoader 3SASQuantumLTO-6 HHSASQUANTUM^UHDL
QUANTUM^ULTRIUM^6
SuperLoader 3SCSIHewlett Packard EnterpriseUltrium 1840 LTO4SCSIQUANTUM^UHDL
HP^^^^^^Ultrium^4-SCSI
SuperLoader 3SCSIQuantumLTO-4 HHSCSIQUANTUM^UHDL
QUANTUM^ULTRIUM^4
  1. L1 and L2 barcode labels on a cleaning media will cause a cleaning utility job to hang indefinitely. Recommend using L3 (or above) barcode labels for cleaning media.
  2. L1 barcode labels on a cleaning media will cause a cleaning utility job to hang indefinitely. Recommend using L2 (or above) barcode labels for cleaning media.
  3. i6000 Dual Robot supported with firmware 630Q-GS0xxxx and above.
Go to Top of "Tape Libraries with Drives"

Spectra Logic

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
Spectra StackFibre ChannelIBMUltrium 6 Half HeightFibre ChannelSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH6
Spectra StackFibre ChannelIBMUltrium 7 Half HeightFibre ChannelSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH7
Spectra StackFibre ChannelIBMUltrium 8 Half HeightFibre ChannelSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH8
Spectra StackSASIBMUltrium 6 Half HeightSASSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH6
Spectra StackSASIBMUltrium 7 Half HeightSASSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH7
Spectra StackSASIBMUltrium 8 Half HeightSASSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH8
Spectra T24SCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSISPECTRA^GECKO
HP^^^^^^Ultrium^3-SCSI
T-series (members) [1][2]Fibre ChannelIBMSystem Storage TS2250 Ultrium 5 Half HeightFibre ChannelSPECTRA^PYTHON
IBM^^^^^ULT3580-HH5
  • f144-1
  • f144-2
T-series (members) [1][2]Fibre ChannelIBMSystem Storage TS2350 Ultrium 5Fibre ChannelSPECTRA^PYTHON
IBM^^^^^ULT3580-TD5
  • f144-1
  • f144-2
T-series (members) [1][2]Fibre ChannelIBMUltrium 3Fibre ChannelSPECTRA^PYTHON
IBM^^^^^ULTRIUM-TD3
  • f144-1
  • f144-2
T-series (members) [1][2]Fibre ChannelIBMUltrium 4Fibre ChannelSPECTRA^PYTHON
IBM^^^^^ULTRIUM-TD4
  • f144-1
  • f144-2
T-series (members) [1][2]Fibre ChannelIBMUltrium 6 Half HeightFibre ChannelSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH6
  • f144-1
  • f144-2
T-series (members) [1][2]Fibre ChannelIBMUltrium 6Fibre ChannelSPECTRA^PYTHON
IBM^^^^^ULTRIUM-TD6
  • f144-1
  • f144-2
T-series (members) [1][2]Fibre ChannelIBMUltrium 7 Half HeightFibre ChannelSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH7
  • f144-1
  • f144-2
T-series (members) [1][2]Fibre ChannelIBMUltrium 7Fibre ChannelSPECTRA^PYTHON
IBM^^^^^ULTRIUM-TD7
  • f144-1
  • f144-2
T-series (members) [1][2]Fibre ChannelIBMUltrium 8 Half HeightFibre ChannelSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH8
  • f144-1
  • f144-2
T-series (members) [1][2]Fibre ChannelIBMUltrium 8Fibre ChannelSPECTRA^PYTHON
IBM^^^^^ULTRIUM-TD8
  • f144-1
  • f144-2
T-series (members) [1][2]SASIBMSystem Storage TS2250 Ultrium 5 Half HeightSASSPECTRA^PYTHON
IBM^^^^^ULT3580-HH5
  • f144-1
  • f144-2
T-series (members) [1][2]SASIBMUltrium 6 Half HeightSASSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH6
  • f144-1
  • f144-2
T-series (members) [1][2]SASIBMUltrium 6SASSPECTRA^PYTHON
IBM^^^^^ULTRIUM-TD6
  • f144-1
  • f144-2
T-series (members) [1][2]SASIBMUltrium 7 Half HeightSASSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH7
  • f144-1
  • f144-2
T-series (members) [1][2]SASIBMUltrium 8 Half HeightSASSPECTRA^PYTHON
IBM^^^^^ULTRIUM-HH8
  • f144-1
  • f144-2
T-series (members) [1]SCSIIBMTotalStorage 3580 Ultrium 3Fibre ChannelSPECTRA^PYTHON
IBM^^^^^ULT3580-TD3
  • f144-1
T-series (members) [1]SCSIIBMTotalStorage 3580 Ultrium 3SCSISPECTRA^PYTHON
IBM^^^^^ULT3580-TD3
  • f144-1
T-series (members) [1]SCSIIBMUltrium 4 (U320)SCSISPECTRA^PYTHON
IBM^^^^^ULTRIUM-TD4
  • f144-1
  1. Minimum library firmware of BlueScale10.4.0-20080908F is suggested for proper import/export operation. Library firmware version is determined in the library GUI, not in the inquiry string.
  2. Refer to Spectra KB article 1286 for incompatible media library issues. (Spectra login required)
Go to Top of "Tape Libraries with Drives"

StorageTek

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
SL500Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelSTK^^^^^SL500
HP^^^^^^Ultrium^3-SCSI
SL500Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelSTK^^^^^SL500
HP^^^^^^Ultrium^4-SCSI
SL500Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelSTK^^^^^SL500
HP^^^^^^Ultrium^5-SCSI
SL500Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelSTK^^^^^SL500
IBM^^^^^ULT3580-TD3
SL500Fibre ChannelIBMUltrium 3Fibre ChannelSTK^^^^^SL500
IBM^^^^^ULTRIUM-TD3
SL500Fibre ChannelIBMUltrium 4 (U160)SCSISTK^^^^^SL500
IBM^^^^^ULTRIUM-TD4
SL500Fibre ChannelIBMUltrium 4Fibre ChannelSTK^^^^^SL500
IBM^^^^^ULTRIUM-TD4
SL500Fibre ChannelIBMUltrium 5Fibre ChannelSTK^^^^^SL500
IBM^^^^^ULTRIUM-TD5
SL500SASHewlett Packard EnterpriseUltrium 3280 LTO5SASSTK^^^^^SL500
HP^^^^^^Ultrium^5-SCSI
SL500SCSIHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelSTK^^^^^SL500
HP^^^^^^Ultrium^3-SCSI
SL500SCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSISTK^^^^^SL500
HP^^^^^^Ultrium^3-SCSI
SL500SCSIIBMTotalStorage 3580 Ultrium 3SCSISTK^^^^^SL500
IBM^^^^^ULT3580-TD3
SL3000 [1]Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelSTK^^^^^SL3000
HP^^^^^^Ultrium^4-SCSI
  • f145-1
SL3000 [1]Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelSTK^^^^^SL3000
HP^^^^^^Ultrium^5-SCSI
  • f145-1
SL3000 [1]Fibre ChannelHewlett Packard EnterpriseUltrium 6650 LTO6Fibre ChannelSTK^^^^^SL3000
HP^^^^^^Ultrium^6-SCSI
  • f145-1
SL3000 [1]Fibre ChannelIBMSystem Storage TS2350 Ultrium 5Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULT3580-TD5
  • f145-1
SL3000 [1]Fibre ChannelIBMUltrium 4Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULTRIUM-TD4
  • f145-1
SL3000 [1]Fibre ChannelIBMUltrium 5Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULTRIUM-TD5
  • f145-1
SL3000 [1]Fibre ChannelIBMUltrium 6Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULTRIUM-TD6
  • f145-1
SL3000 [1]Fibre ChannelIBMUltrium 7Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULTRIUM-TD7
  • f145-1
SL3000 [1]Fibre ChannelIBMUltrium 8Fibre ChannelSTK^^^^^SL3000
IBM^^^^^ULTRIUM-TD8
  • f145-1
SL3000 [1][2]Fibre ChannelOracleStorageTek T10000DFibre ChannelSTK^^^^^SL3000
STK^^^^^T10000D
  • f145-1
  • f145-2
SL3000 [1]Fibre ChannelStorageTekT9840CFibre ChannelSTK^^^^^SL3000
STK^^^^^T9840C
  • f145-1
SL3000 [1]Fibre ChannelStorageTekT9840DFibre ChannelSTK^^^^^SL3000
STK^^^^^T9840D
  • f145-1
SL3000 [1]Fibre ChannelStorageTekT10000AFibre ChannelSTK^^^^^SL3000
STK^^^^^T10000A
  • f145-1
SL3000 [1]Fibre ChannelStorageTekT10000BFibre ChannelSTK^^^^^SL3000
STK^^^^^T10000B
  • f145-1
SL3000 [1]Fibre ChannelStorageTekT10000CFibre ChannelSTK^^^^^SL3000
STK^^^^^T10000C
  • f145-1
  1. Minimum library firmware level of 2.30 is required.
  2. Minimum tape drive firmware level of 4.09 is required.
Go to Top of "Tape Libraries with Drives"

Sun

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
StorageTek SL24Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
StorageTek SL24Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
StorageTek SL24Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
StorageTek SL24SASHewlett Packard EnterpriseUltrium 920 LTO3SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
StorageTek SL24SASHewlett Packard EnterpriseUltrium 1760 LTO4SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
StorageTek SL24SASHewlett Packard EnterpriseUltrium 3000 LTO5SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
StorageTek SL24SCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
StorageTek SL24SCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
StorageTek SL24SCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
StorageTek SL24SCSIHewlett Packard EnterpriseUltrium 1840 LTO4SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
StorageTek SL48Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
StorageTek SL48Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
StorageTek SL48Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
StorageTek SL48SASHewlett Packard EnterpriseUltrium 920 LTO3SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
StorageTek SL48SASHewlett Packard EnterpriseUltrium 1760 LTO4SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
StorageTek SL48SASHewlett Packard EnterpriseUltrium 3000 LTO5SASHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^5-SCSI
StorageTek SL48SCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
StorageTek SL48SCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^3-SCSI
StorageTek SL48SCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
StorageTek SL48SCSIHewlett Packard EnterpriseUltrium 1840 LTO4SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^4-SCSI
Go to Top of "Tape Libraries with Drives"

Tandberg

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
WinBESRMALNDMPESO
StorageLibrary T24Fibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelEXABYTE^MAGNUM^224
HP^^^^^^Ultrium^4-SCSI
StorageLibrary T24Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelEXABYTE^MAGNUM^224
HP^^^^^^Ultrium^5-SCSI
StorageLibrary T24Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelEXABYTE^MAGNUM^224
HP^^^^^^Ultrium^6-SCSI
StorageLibrary T24Fibre ChannelIBMUltrium 3Fibre ChannelEXABYTE^MAGNUM^224
IBM^^^^^ULTRIUM-TD3
StorageLibrary T24Fibre ChannelIBMUltrium 4Fibre ChannelEXABYTE^MAGNUM^224
IBM^^^^^ULTRIUM-TD4
StorageLibrary T24SASHewlett Packard EnterpriseUltrium 1760 LTO4SASEXABYTE^MAGNUM^224
HP^^^^^^Ultrium^4-SCSI
StorageLibrary T24SASHewlett Packard EnterpriseUltrium 3000 LTO5SASEXABYTE^MAGNUM^224
HP^^^^^^Ultrium^5-SCSI
StorageLibrary T24SASHewlett Packard EnterpriseUltrium 6250 LTO6SASEXABYTE^MAGNUM^224
HP^^^^^^Ultrium^6-SCSI
StorageLibrary T24SASIBMUltrium 4 Half HeightSASEXABYTE^MAGNUM^224
IBM^^^^^ULTRIUM-HH4
StorageLibrary T24SCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIEXABYTE^MAGNUM^224
HP^^^^^^Ultrium^3-SCSI
StorageLibrary T24SCSIIBMUltrium 3SCSIEXABYTE^MAGNUM^224
IBM^^^^^ULTRIUM-TD3
StorageLibrary T24SCSIIBMUltrium 4 (U160)SCSIEXABYTE^MAGNUM^224
IBM^^^^^ULTRIUM-TD4
StorageLibrary T24SCSIIBMUltrium 4 Half Height (U320)SCSIEXABYTE^MAGNUM^224
IBM^^^^^ULTRIUM-HH4
StorageLibrary T40+/T80+/T120+/T160+ series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 1760 LTO4Fibre ChannelTANDBERGStorageLoader
HP^^^^^^Ultrium^4-SCSI
StorageLibrary T40+/T80+/T120+/T160+ series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelTANDBERGStorageLoader
HP^^^^^^Ultrium^5-SCSI
StorageLibrary T40+/T80+/T120+/T160+ series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelTANDBERGStorageLoader
HP^^^^^^Ultrium^5-SCSI
StorageLibrary T40+/T80+/T120+/T160+ series (members)Fibre ChannelHewlett Packard EnterpriseUltrium 6250 LTO6Fibre ChannelTANDBERGStorageLoader
HP^^^^^^Ultrium^6-SCSI
StorageLibrary T40+/T80+/T120+/T160+ series (members)Fibre ChannelIBMUltrium 3Fibre ChannelTANDBERGStorageLoader
IBM^^^^^ULTRIUM-TD3
StorageLibrary T40+/T80+/T120+/T160+ series (members)Fibre ChannelIBMUltrium 4Fibre ChannelTANDBERGStorageLoader
IBM^^^^^ULTRIUM-TD4
StorageLibrary T40+/T80+/T120+/T160+ series (members)SASHewlett Packard EnterpriseUltrium 1760 LTO4SASTANDBERGStorageLoader
HP^^^^^^Ultrium^4-SCSI
StorageLibrary T40+/T80+/T120+/T160+ series (members)SASHewlett Packard EnterpriseUltrium 3000 LTO5SASTANDBERGStorageLoader
HP^^^^^^Ultrium^5-SCSI
StorageLibrary T40+/T80+/T120+/T160+ series (members)SASHewlett Packard EnterpriseUltrium 6250 LTO6SASTANDBERGStorageLoader
HP^^^^^^Ultrium^6-SCSI
StorageLibrary T40+/T80+/T120+/T160+ series (members)SASIBMUltrium 4 Half HeightSASTANDBERGStorageLoader
IBM^^^^^ULTRIUM-HH4
StorageLibrary T40+/T80+/T120+/T160+ series (members)SCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSITANDBERGStorageLoader
HP^^^^^^Ultrium^4-SCSI
StorageLibrary T40+/T80+/T120+/T160+ series (members)SCSIIBMUltrium 3SCSITANDBERGStorageLoader
IBM^^^^^ULTRIUM-TD3
StorageLibrary T40+/T80+/T120+/T160+ series (members)SCSIIBMUltrium 4 (U320)SCSITANDBERGStorageLoader
IBM^^^^^ULTRIUM-TD4
StorageLibrary T40+/T80+/T120+/T160+ series (members)SCSIIBMUltrium 4 Half Height (U320)SCSITANDBERGStorageLoader
IBM^^^^^ULTRIUM-HH4
StorageLibrary T40Fibre ChannelIBMUltrium 3Fibre ChannelTANDBERGStorageLoader
IBM^^^^^ULTRIUM-TD3
StorageLibrary T40Fibre ChannelIBMUltrium 4Fibre ChannelTANDBERGStorageLoader
IBM^^^^^ULTRIUM-TD4
StorageLibrary T40SCSIIBMUltrium 3SCSITANDBERGStorageLoader
IBM^^^^^ULTRIUM-TD3
StorageLibrary T40SCSIIBMUltrium 4 (U160)SCSITANDBERGStorageLoader
IBM^^^^^ULTRIUM-TD4
StorageLibrary T48Fibre ChannelIBMUltrium 3Fibre ChannelEXABYTE^MAGNUM^448
IBM^^^^^ULTRIUM-TD3
StorageLibrary T48Fibre ChannelIBMUltrium 4Fibre ChannelEXABYTE^MAGNUM^448
IBM^^^^^ULTRIUM-TD4
StorageLibrary T48SASIBMUltrium 4 Half HeightSASEXABYTE^MAGNUM^448
IBM^^^^^ULTRIUM-HH4
StorageLibrary T48SCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIEXABYTE^MAGNUM^448
HP^^^^^^Ultrium^3-SCSI
StorageLibrary T48SCSIIBMUltrium 3SCSIEXABYTE^MAGNUM^448
IBM^^^^^ULTRIUM-TD3
StorageLibrary T48SCSIIBMUltrium 4 (U160)SCSIEXABYTE^MAGNUM^448
IBM^^^^^ULTRIUM-TD4
StorageLibrary T48SCSIIBMUltrium 4 Half Height (U320)SCSIEXABYTE^MAGNUM^448
IBM^^^^^ULTRIUM-HH4
StorageLoader 2U LTOSCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSIEXABYTE^MAGNUM^224
HP^^^^^^Ultrium^3-SCSI
StorageLoader 2U LTOSCSIIBMTotalStorage 3580 Ultrium 3SCSIEXABYTE^MAGNUM^224
IBM^^^^^ULT3580-TD3
StorageLoader 2U LTOSCSIIBMUltrium 4 (U160)SCSIEXABYTE^MAGNUM^224
IBM^^^^^ULTRIUM-TD4
StorageLoader LTOFibre ChannelHewlett Packard EnterpriseUltrium 3000 LTO5Fibre ChannelTANDBERGStorageLoader
HP^^^^^^Ultrium^5-SCSI
StorageLoader LTOSASHewlett Packard EnterpriseUltrium 1760 LTO4SASTANDBERGStorageLoader
HP^^^^^^Ultrium^4-SCSI
StorageLoader LTOSASHewlett Packard EnterpriseUltrium 3000 LTO5SASTANDBERGStorageLoader
HP^^^^^^Ultrium^5-SCSI
StorageLoader LTOSASHewlett Packard EnterpriseUltrium 6250 LTO6SASTANDBERGStorageLoader
HP^^^^^^Ultrium^6-SCSI
StorageLoader LTOSASIBMUltrium 4 Half HeightSASTANDBERGStorageLoader
IBM^^^^^ULTRIUM-HH4
StorageLoader LTOSCSIHewlett Packard EnterpriseUltrium 920 LTO3SCSITANDBERGStorageLoader
HP^^^^^^Ultrium^3-SCSI
StorageLoader LTOSCSIHewlett Packard EnterpriseUltrium 1760 LTO4SCSITANDBERGStorageLoader
HP^^^^^^Ultrium^4-SCSI

Tape Library Families

When a hardware family of devices is listed, refer to this section for a definition of family members. Generally speaking, the family name and members are defined by the hardware manufacturer, and share common operational traits. In some cases, a specific member of the family may not be supported in the same fashion as the other members. When this occurs, a footnote in the hardware category section will indentify this limitation.

Go to Top of "Tape Library Families"

Dell EMC

BacktrackFamilyInterfaceFamily Members
BacktrackPowerVault ML6000 SeriesFibre ChannelPowerVault ML6010, PowerVault ML6020, PowerVault ML6030
BacktrackPowerVault ML6000 SeriesSASPowerVault ML6010, PowerVault ML6020, PowerVault ML6030
BacktrackPowerVault ML6000 SeriesSCSIPowerVault ML6010, PowerVault ML6020, PowerVault ML6030
BacktrackPowerVault TL2000/TL4000 seriesFibre ChannelPowerVault TL2000, PowerVault TL4000
BacktrackPowerVault TL2000/TL4000 seriesSASPowerVault TL2000, PowerVault TL4000
BacktrackPowerVault TL2000/TL4000 seriesSCSIPowerVault TL2000, PowerVault TL4000
Go to Top of "Tape Library Families"

Fujitsu

BacktrackFamilyInterfaceFamily Members
BacktrackETERNUS LT20/40/60 S2Fibre ChannelETERNUS LT20 S2, ETERNUS LT40 S2, ETERNUS LT60 S2
BacktrackETERNUS LT20/40/60 S2SASETERNUS LT20 S2, ETERNUS LT40 S2, ETERNUS LT60 S2
Go to Top of "Tape Library Families"

Hewlett Packard Enterprise

BacktrackFamilyInterfaceFamily Members
BacktrackEML E-SeriesFibre ChannelEML E-Series 71e, EML E-Series 103e, EML E-Series 245e, EML E-Series 348e, EML E-Series 375e, EML E-Series 442e, EML E-Series 469e, EML E-Series 505e
BacktrackMSL2024/4048/8048/8096 (G3 series)Fibre ChannelMSL2024, MSL4048, MSL8048, MSL8096
BacktrackMSL2024/4048/8048/8096 (G3 series)SASMSL2024, MSL4048, MSL8048, MSL8096
BacktrackMSL2024/4048/8048/8096 (G3 series)SCSIMSL2024, MSL4048, MSL8048, MSL8096
Go to Top of "Tape Library Families"

Hitachi

BacktrackFamilyInterfaceFamily Members
BacktrackL-SeriesFibre ChannelL1/30A, L2/30A, L20/300
BacktrackL-SeriesSASL1/30A, L2/30A, L20/300
Go to Top of "Tape Library Families"

IBM

BacktrackFamilyInterfaceFamily Members
BacktrackSystem Storage TS3100/TS3200 (Machine Type 3573)Fibre ChannelSystem Storage TS3100 (Machine Type 3573), System Storage TS3200 (Machine Type 3573)
BacktrackSystem Storage TS3100/TS3200 (Machine Type 3573)SASSystem Storage TS3100 (Machine Type 3573), System Storage TS3200 (Machine Type 3573)
BacktrackSystem Storage TS3100/TS3200 (Machine Type 3573)SCSISystem Storage TS3100 (Machine Type 3573), System Storage TS3200 (Machine Type 3573)
Go to Top of "Tape Library Families"

NEC

BacktrackFamilyInterfaceFamily Members
BacktrackT30A/T60AFibre ChannelT30A, T60A
BacktrackT30A/T60ASAST30A, T60A
Go to Top of "Tape Library Families"

Overland Storage

BacktrackFamilyInterfaceFamily Members
BacktrackNEO E-SeriesFibre ChannelNEO 2000e, NEO 4000e, NEO 8000e
BacktrackNEO E-SeriesSASNEO 2000e, NEO 4000e, NEO 8000e
BacktrackNEO E-SeriesSCSINEO 2000e, NEO 4000e, NEO 8000e
BacktrackNEOs seriesFibre ChannelNEO 200s, NEO 400s
BacktrackNEOs seriesSASNEO 200s, NEO 400s
BacktrackNEOs seriesSCSINEO 200s, NEO 400s
BacktrackNEOs series 2nd GenerationFibre ChannelNEO 200s 2nd Generation, NEO 400s 2nd Generation
BacktrackNEOs series 2nd GenerationSASNEO 200s 2nd Generation, NEO 400s 2nd Generation
BacktrackNEOs series 3rd GenerationFibre ChannelNEOs StorageLoader, NEOs T24, NEOs T48
BacktrackNEOs series 3rd GenerationSASNEOs StorageLoader, NEOs T24, NEOs T48
BacktrackNEOxl seriesFibre ChannelNEOxl 40, NEOxl 60, NEOxl 80
BacktrackNEOxl seriesSASNEOxl 40, NEOxl 60, NEOxl 80
Go to Top of "Tape Library Families"

Qualstar

BacktrackFamilyInterfaceFamily Members
BacktrackQ24/Q48Fibre ChannelQ24, Q48
BacktrackQ24/Q48SASQ24, Q48
BacktrackRLS-8000 LTO seriesFibre ChannelRLS-8204, RLS-8236, RLS-8244
BacktrackRLS-8000 LTO seriesSASRLS-8204, RLS-8236, RLS-8244
BacktrackRLS-8000 LTO seriesSCSIRLS-8204, RLS-8236, RLS-8244
BacktrackRLS-8000D LTO seriesFibre ChannelRLS-8204D, RLS-8236D, RLS-8244D
BacktrackRLS-8000D LTO seriesSASRLS-8204D, RLS-8236D, RLS-8244D
BacktrackRLS-8500 LTO seriesFibre ChannelRLS-8350, RLS-8560, RLS-85120
BacktrackRLS-8500 LTO seriesSASRLS-8350, RLS-8560, RLS-85120
BacktrackTLS-5000 SAIT seriesSCSITLS-5433, TLS-5466, TLS-58132, TLS-58264
BacktrackTLS-8000 LTO seriesFibre ChannelTLS-8211, TLS-8222, TLS-8433, TLS-8466, TLS-88132, TLS-88264
BacktrackTLS-8000 LTO seriesSASTLS-8211, TLS-8222, TLS-8433, TLS-8466, TLS-88132, TLS-88264
BacktrackTLS-8000 LTO seriesSCSITLS-8211, TLS-8222, TLS-8433, TLS-8466, TLS-88132, TLS-88264
BacktrackXLS seriesFibre ChannelXLS-8000, XLS-802500, XLS-810160, XLS-810240, XLS-812300, XLS-832700, XLS-8161100
Go to Top of "Tape Library Families"

Quantum

BacktrackFamilyInterfaceFamily Members
BacktrackScalar i40/i80 seriesFibre ChannelScalar i40, Scalar i80
BacktrackScalar i40/i80 seriesSASScalar i40, Scalar i80
Go to Top of "Tape Library Families"

Spectra Logic

BacktrackFamilyInterfaceFamily Members
BacktrackT-seriesFibre ChannelSpectra T50, Spectra T50e, Spectra T120, Spectra T200, Spectra T380, Spectra T680, Spectra T950
BacktrackT-seriesSASSpectra T50e, Spectra T120
BacktrackT-seriesSCSISpectra T50, Spectra T50e, Spectra T120, Spectra T200, Spectra T380, Spectra T680, Spectra T950
Go to Top of "Tape Library Families"

Tandberg

BacktrackFamilyInterfaceFamily Members
BacktrackStorageLibrary T40+/T80+/T120+/T160+ seriesFibre ChannelStorageLibrary T40+, StorageLibrary T80+, StorageLibrary T120+, StorageLibrary T160+
BacktrackStorageLibrary T40+/T80+/T120+/T160+ seriesSASStorageLibrary T40+, StorageLibrary T80+, StorageLibrary T120+, StorageLibrary T160+
BacktrackStorageLibrary T40+/T80+/T120+/T160+ seriesSCSIStorageLibrary T40+, StorageLibrary T80+, StorageLibrary T120+, StorageLibrary T160+

NDMP Platforms

The NDMP platform support information is listed below. This information is organized by vendor manufacturer/model(s), minimum software required, method of connection, and any other important notes or information relevant to the hardware and its compatibility.

The storage devices supported by the NDMP option are included with the Tape Library / Virtual Tape Library sections. In these sections, search by storage device vendor, then model, then look for a check [] in the NDMP column for support. Please note that the presence of a check means that Veritas will support the storage device and NDMP combination IF and ONLY IF the NDMP vendor also supports the library / drive combination. Please refer to the NDMP vendors' documentation for storage device support and possible limitations. If known, these compatibility lists are listed in the notes section by vendor.

Please Note:

1. The tape library drivers are supplied by Veritas with Backup Exec 20.

2. The tape drive drivers are supplied by the NDMP platform vendor when using Direct-attach or 3-Way NDMP Connection methods.

3. NDMP only supports libraries (real or virtual). Stand-alone tape drives are not supported when using Direct-attach or 3-Way NDMP Connection methods.

4. Validate that firewalls allow NDMP traffic.

5. LTO8 and LTO7 support is very new. Please verify the LTO drives supported with your NDMP platform provider.

6. This NDMP hardware section is only required when using the Backup Exec NDMP option. The Backup Exec NDMP option is typically used for backing up file data on the below listed NDMP/NAS servers. If the NDMP/NAS server contains VM images or databases, those items are typically better protected via other Backup Exec Agents or Options.

NDMP Option minimum requirements:

1. NDMP v4 is required.

2. The NDMP server has the Network Data Management Protocol enabled.

The following table describes the supported NDMP connection methods. Veritas supports these connection methods, provided the NDMP platform vendor does as well.

Go to Top of "NDMP Platforms"

NDMP Connection Methods

Connection MethodDescription
Direct-attachData travels from NDMP disk to a tape device on the same NDMP host, or from NDMP disk to a tape device on a SAN. Backup data is NOT sent over the local Ethernet network. The tape device is connected directly to the NAS device via SCSI or Fibre Channel. This is the only NDMP Connection Method that is "LAN free".
RemoteData travels from the NDMP host, across the local Ethernet network to a Backup Exec server, and then to a tape or disk device connected to the Backup Exec server. Any Backup Exec supported tape or disk device can be used with this Connection Method. A checkmark is NOT needed in the NDMP column of the tape library since the target tape or disk device is not directly connected to the NDMP/NAS. This is the only Connection Method available if the NDMP server doesn't support attaching a local tape library via SCSI or Fibre Channel.
3-wayData travels from disk on an NDMP host to a tape device on another NDMP host of the same vendor/brand/family. Backup data is sent over the local network. This requires multiple NDMP servers from the same vendor/brand/family. The target tape device must have a checkmark in the NDMP column.
Go to Top of "NDMP Platforms"

Dell EMC

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
Compellent FS8600 [1]FluidFS 2.0Remote
  • f160-1
Compellent FS8600 [1]FluidFS 3.0Remote
  • f160-1
Compellent FS8600FluidFS 4.0Remote
Compellent FS8600 [2]FluidFS 5.0Remote
  • f160-2
Compellent FS8600 [3]FluidFS 6.0Remote
  • f160-3
Compellent FS8600 [4]FluidFS 7.0Remote
  • f160-4
EqualLogic FS7500 [1]Scalable File System 1.0Remote
  • f160-1
EqualLogic FS7500 [1]FluidFS 2.0Remote
  • f160-1
EqualLogic FS7500 [1]FluidFS 3.0Remote
  • f160-1
EqualLogic FS7500FluidFS 4.0Remote
EqualLogic FS7600 [1]FluidFS 2.0Remote
  • f160-1
EqualLogic FS7600 [1]FluidFS 3.0Remote
  • f160-1
EqualLogic FS7600FluidFS 4.0Remote
EqualLogic FS7610 [1]FluidFS 2.0Remote
  • f160-1
EqualLogic FS7610 [1]FluidFS 3.0Remote
  • f160-1
EqualLogic FS7610FluidFS 4.0Remote
PowerVault NX3500 [1]Scalable File System 1.0Remote
  • f160-1
PowerVault NX3500 [1]FluidFS 2.0Remote
  • f160-1
PowerVault NX3500 [1]FluidFS 3.0Remote
  • f160-1
PowerVault NX3600 [1]FluidFS 2.0Remote
  • f160-1
PowerVault NX3600 [1]FluidFS 3.0Remote
  • f160-1
PowerVault NX3610 [1]FluidFS 2.0Remote
  • f160-1
PowerVault NX3610 [1]FluidFS 3.0Remote
  • f160-1
Unity series (members) [5][6]Unity Operating Environment 4.0Remote, 3-way
  • f160-5
  • f160-6
Unity series (members) [6]Unity Operating Environment 4.1Remote, 3-way
  • f160-6
Unity series (members) [6]Unity Operating Environment 4.2Remote, 3-way
  • f160-6
Unity series (members) [6]Unity Operating Environment 4.3Remote, 3-way
  • f160-6
Unity series (members) [6][7][8][9]Unity Operating Environment 4.4Direct Attach, Remote, 3-way
  • f160-6
  • f160-7
  • f160-8
  • f160-9
VNX2 series (members) [6]VNX File 8.1Direct Attach, Remote, 3-way
  • f160-6
VNX2e series (members) [6][10][11]VNXe Operating Environment v3.1Remote, 3-way
  • f160-6
  • f160-10
  • f160-11
VNXe series (members) [6][11]VNXe Operating Environment v2.0Remote, 3-way
  • f160-6
  • f160-11
VNXe series (members) [6][11]VNXe Operating Environment v2.4Remote, 3-way
  • f160-6
  • f160-11
VNX series (members) [6]VNX File 7.0Direct Attach, Remote, 3-way
  • f160-6
VNX series (members) [6]VNX File 7.1Direct Attach, Remote, 3-way
  • f160-6
  1. Please note: this device is nearing the end of support. Please see the 'Retiring Soon' section.
  2. Dell EMC versioning clarification: Dell EMC marketing refers to it as v5, but it shows up in the adamm.log as "Operating System Version 1.5.0.xxxx". This is consistent with their earlier versioning style, v4 = 1.4, v3 = 1.3, v2 = 1.2, etc.
  3. Dell EMC versioning clarification: Dell EMC marketing refers to it as v6, but it shows up in the adamm.log as "Operating System Version 1.6.0.xxxx". This is consistent with their earlier versioning style, v4 = 1.4, v3 = 1.3, v2 = 1.2, etc.
  4. Dell EMC versioning clarification: Dell EMC marketing refers to it as v7, but it shows up in the adamm.log as "Operating System Version 1.7.0.xxxx". This is consistent with their earlier versioning style, v4 = 1.4, v3 = 1.3, v2 = 1.2, etc.
  5. EMC Unity firmware 4.0.1.8194551 (SP1) (or higher) is required.
  6. EMC's HCL can be found here: https://elabnavigator.emc.com Select "Customers and Partners" and then select PDFs and Guides and open Celerra .pdf
  7. Direct-attach support has a maximum tape block size of 64kB by default. Consult Unity documentation to enable proper functionality for larger block sizes.
  8. Direct-attach support requires Unity Operating Environment version 4.4.1.1538211294 or later.
  9. Direct-attach support requires that SCSI reservations be enabled manually (the scsiReserve setting). Please see Unity documentation.
  10. EMC VNXe firmware 3.1.5.6801782 (or higher) is required.
  11. VNXe supports "3-way" with the restriction that VNXe can't support the NDMP Tape Server part of a 3-way operation. 3-way requires a VNX or Celerra data mover as the NDMP Tape Server. ESO is supported when used with a 3-way connection.
Go to Top of "NDMP Platforms"

Dell EMC Isilon

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
Scale-Out NAS (members) [1]OneFS 5.5.7.9Direct Attach, Remote, 3-way
  • f161-1
Scale-Out NAS (members) [2]OneFS 6.5.1.8Direct Attach, Remote, 3-way
  • f161-2
Scale-Out NAS (members) [3]OneFS 7.0Direct Attach, Remote, 3-way
  • f161-3
Scale-Out NAS (members) [4]OneFS 7.1Direct Attach, Remote, 3-way
  • f161-4
Scale-Out NAS (members) [5]OneFS 7.2Direct Attach, Remote, 3-way
  • f161-5
Scale-Out NAS (members) [6][7]OneFS 8.0Direct Attach, Remote, 3-way
  • f161-6
  • f161-7
Scale-Out NAS (members) [8][9]OneFS 8.1Direct Attach, Remote, 3-way
  • f161-8
  • f161-9
  1. Direct Access Recovery (DAR) and Directory Direct Access Recovery (DDAR) are currently not supported with this device/software combination.
  2. OneFS versions 6.5.x are supported.
  3. OneFS versions 7.0.x are supported.
  4. OneFS versions 7.1.x are supported.
  5. OneFS versions 7.2.x are supported.
  6. OneFS version 8.0.0.5 (or higher 8.0.0.x) is supported.
  7. OneFS version 8.0.1.2 (or higher 8.0.1.x) is supported.
  8. OneFS version 8.1.0.1 (or higher) is supported.
  9. OneFS version 8.1.0.2 backups fail when using 3-way backups and tagged VLAN. Please consult Isilon about issue 207873 or upgrade.
Go to Top of "NDMP Platforms"

Hitachi

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
NAS Platform, 4000 and 3000 Series (members) [1]Hitachi NAS OS 11Direct Attach, Remote, 3-way
  • f162-1
NAS Platform, 4000 and 3000 Series (members) [2]Hitachi NAS OS 12Direct Attach, Remote, 3-way
  • f162-2
NAS Platform, 4000 and 3000 Series (members) [3]Hitachi NAS OS 13Direct Attach, Remote, 3-way
  • f162-3
NAS Platform F1000 (HNAS F1000) (members) [4][5]FOS 4.1Remote
  • f162-4
  • f162-5
NAS Platform F1000 (HNAS F1000) (members) [5]FOS 5.0Remote
  • f162-5
Virtual File Platform (VFP) (members) [4][5]FOS 4.1Remote
  • f162-4
  • f162-5
Virtual File Platform (VFP) (members) [5]FOS 5.0Remote
  • f162-5
VSP Gx00/Fx00 series (members) [3]Hitachi NAS OS 13Direct Attach, Remote, 3-way
  • f162-3
  1. Hitachi NAS OS versions 11.x are supported.
  2. Hitachi NAS OS versions 12.x are supported.
  3. Hitachi NAS OS versions 13.x are supported.
  4. FOS 4.1.1-00 or later version is required.
  5. The restore from the incremental backup set fails if the backup set has no backup data.
Go to Top of "NDMP Platforms"

IBM

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
Scale Out Network Attached Storage (SONAS) [1][2]IBM OS 1.4Remote
  • f163-1
  • f163-2
Scale Out Network Attached Storage (SONAS) [1][2]IBM OS 1.5Remote
  • f163-1
  • f163-2
Storwize series (members) [1][2]IBM OS 1.4Remote
  • f163-1
  • f163-2
Storwize series (members) [1][2]IBM OS 1.5Remote
  • f163-1
  • f163-2
Storwize series (members) [1][2]IBM OS 1.6Remote
  • f163-1
  • f163-2
System Storage N series (members) [3]Data ONTAP 7.2.3Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [3]Data ONTAP 7.3.6Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [3]Data ONTAP v8.0 (7-Mode)Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [3]Data ONTAP v8.0 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [3]Data ONTAP v8.1 (7-Mode)Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [3]Data ONTAP v8.1 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [3]Data ONTAP v8.1.2 (7-Mode)Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [3]Data ONTAP v8.1.2 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [3]Data ONTAP v8.1.3 (7-Mode)Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [3]Data ONTAP v8.1.3 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [3]Data ONTAP v8.1.4 (7-Mode)Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [3]Data ONTAP v8.1.4 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f163-3
System Storage N series (members) [4][5]Data ONTAP v8.2 (7-Mode)Direct Attach, Remote, 3-way
  • f163-4
  • f163-5
System Storage N series (members) [4][5][6]Data ONTAP v8.2 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f163-4
  • f163-5
  • f163-6
System Storage N series (members) [4][5]Data ONTAP v8.2.2 (7-Mode)Direct Attach, Remote, 3-way
  • f163-4
  • f163-5
System Storage N series (members) [4][5][6]Data ONTAP v8.2.2 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f163-4
  • f163-5
  • f163-6
  1. The IBM document "Implementing an effective NDMP backup solution on IBM Storwize V7000 Unified system using Symantec Backup Exec 2014" is a good overview. https://www-356.ibm.com/partnerworld/wps/servlet/download/DownloadServlet?id=_7E$S5TzsZziPCA$cnt&attachmentName=Implementing_ndmp_backup_solution_on_ibm_storwize_v7000_unified.pdf
  2. Within the Backup Exec options for a backup job, the NDMP setting "BACKUP_GROUPEXPIRATION" may need to be set to "0_SEC" for level backups to work correctly. Consult the IBM documents for more details.
  3. Please note: this device is nearing the end of support. Please see the 'Retiring Soon' section.
  4. Browsing of volumes (Backup Selections) is not available. Please use the Include/Exclude feature to configure the backup selections. Please see http://www.veritas.com/docs/000022865
  5. IBM System Storage N series tape support: http://www-03.ibm.com/systems/storage/network/interophome.html
  6. NetApp clustered data ONTAP (CDOT) features such as service name virtualization and multi-tenancy (VSERVER) capabilities are not supported. Node-scoped NDMP mode is required to be enabled. More information is available at https://library.netapp.com/ecmdocs/ECMP1368707/html/GUID-21B82CCB-97F1-4FA6-BB22-095E97979110.html
Go to Top of "NDMP Platforms"

Imation

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
Nexsan NST5000NestOS 2.2Remote
Go to Top of "NDMP Platforms"

LSI Logic

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
Cougar 3000/6000 Series NAS GatewayEverON 4.0.4.6Direct Attach, Remote, 3-way
Go to Top of "NDMP Platforms"

NetApp

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
FAS Series (members) [1]Data ONTAP v7.0.3Direct Attach, Remote, 3-way
  • f166-1
FAS Series (members) [1]Data ONTAP v7.2.3Direct Attach, Remote, 3-way
  • f166-1
FAS Series (members) [1]Data ONTAP v7.3.1Direct Attach, Remote, 3-way
  • f166-1
FAS Series (members) [1]Data ONTAP v7.3.6Direct Attach, Remote, 3-way
  • f166-1
FAS Series (members) [1]Data ONTAP v8.0 (7-Mode)Direct Attach, Remote, 3-way
  • f166-1
FAS Series (members) [1]Data ONTAP v8.0 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-1
FAS Series (members) [2]Data ONTAP v8.1 (7-Mode)Direct Attach, Remote, 3-way
  • f166-2
FAS Series (members) [2]Data ONTAP v8.1 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-2
FAS Series (members) [2]Data ONTAP v8.1.1 (7-Mode)Direct Attach, Remote, 3-way
  • f166-2
FAS Series (members) [2]Data ONTAP v8.1.1 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-2
FAS Series (members) [2]Data ONTAP v8.1.2 (7-Mode)Direct Attach, Remote, 3-way
  • f166-2
FAS Series (members) [2]Data ONTAP v8.1.2 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-2
FAS Series (members) [2]Data ONTAP v8.1.3 (7-Mode)Direct Attach, Remote, 3-way
  • f166-2
FAS Series (members) [2]Data ONTAP v8.1.3 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-2
FAS Series (members) [2]Data ONTAP v8.1.4 (7-Mode)Direct Attach, Remote, 3-way
  • f166-2
FAS Series (members) [2]Data ONTAP v8.1.4 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-2
FAS Series (members) [2][3]Data ONTAP v8.2 (7-Mode)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
FAS Series (members) [2][3][4]Data ONTAP v8.2 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
FAS Series (members) [2][3]Data ONTAP v8.2.1 (7-Mode)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
FAS Series (members) [2][3][4]Data ONTAP v8.2.1 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
FAS Series (members) [2][3]Data ONTAP v8.2.2 (7-Mode)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
FAS Series (members) [2][3][4]Data ONTAP v8.2.2 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
FAS Series (members) [2][3]Data ONTAP v8.2.3 (7-Mode)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
FAS Series (members) [2][3][4]Data ONTAP v8.2.3 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
FAS Series (members) [2][3][5]Data ONTAP v8.2.4 (7-mode)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-5
FAS Series (members) [2][3][4][5]Data ONTAP v8.2.4 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
  • f166-5
FAS Series (members) [2][3][4][6][7]Data ONTAP v8.3 (Clustered)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
  • f166-6
  • f166-7
FAS Series (members) [2][3][4][6][7][8]Data ONTAP v8.3.2 (Clustered)Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
  • f166-6
  • f166-7
  • f166-8
FAS Series (members) [2][3][4][7]Data ONTAP v9.0Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
  • f166-7
FAS Series (members) [2][3][4][7]Data ONTAP v9.1Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
  • f166-7
FAS Series (members) [2][3][4][7]Data ONTAP v9.2Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
  • f166-7
FAS Series (members) [2][3][4][7]Data ONTAP v9.3Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
  • f166-7
FAS Series (members) [2][3][4][7]Data ONTAP v9.4Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
  • f166-7
FAS Series (members) [2][3][4][7]Data ONTAP v9.5Direct Attach, Remote, 3-way
  • f166-2
  • f166-3
  • f166-4
  • f166-7
FAS Series (members)Data ONTAP v9.6Direct Attach, Remote, 3-way
GX series [2]Data ONTAP v8.0 (Cluster-Mode)Direct Attach, Remote, 3-way
  • f166-2
  1. Please note: this device is nearing the end of support. Please see the 'Retiring Soon' section.
  2. NetApp's HCL can be found here: http://www.netapp.com/us/solutions/a-z/data-protection-devices.html
  3. Browsing of volumes (Backup Selections) is not available. Please use the Include/Exclude feature to configure the backup selections. Please see http://www.veritas.com/docs/000022865
  4. NetApp clustered data ONTAP (CDOT) features such as service name virtualization and multi-tenancy (VSERVER) capabilities are not supported. Node-scoped NDMP mode is required to be enabled. More information is available at https://library.netapp.com/ecmdocs/ECMP1368707/html/GUID-21B82CCB-97F1-4FA6-BB22-095E97979110.html
  5. 8.2.4 requires NetApp P-release version 8.2.4p3 (or higher patch)
  6. 8.3.1 is not supported. This is due to changes made by NetApp that causes Verify to fail during Incremental Backups.
  7. NetApp Data ONTAP replication feature SnapMirror is not supported. All Verify operations fail on a read-only volume. Verify being "on" is the default configuration, so all backups appear to fail.
  8. 8.3.2 requires NetApp P-release version 8.3.2p1 (or higher patch)
Go to Top of "NDMP Platforms"

Oracle

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
ZFS Storage Appliance series (members) [1]Oracle OS 2010.08.17Direct Attach, Remote, 3-way
  • f167-1
ZFS Storage Appliance series (members) [1]Oracle OS 2013.06.05Direct Attach, Remote, 3-way
  • f167-1
  1. Support for clustering of the Oracle Sun NDMP devices was not specifically tested, though may work. Contact Oracle for usage of this environment.
Go to Top of "NDMP Platforms"

Veritas

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
FileStoreFileStore 5.6Remote
FileStoreFileStore 5.7Remote

NDMP Families

Go to Top of "NDMP Families"

Dell EMC

BacktrackFamilyFamily Members
BacktrackUnity seriesUnity 300, Unity 300F, Unity 350F, Unity 400, Unity 400F, Unity 450F, Unity 500, Unity 500F, Unity 550F, Unity 600, Unity 600F, Unity 650F, Unity VSA
BacktrackVNX2 seriesVNX5200, VNX5400, VNX5600, VNX5800, VNX7600, VNX8000
BacktrackVNX2e seriesVNXe1600, VNXe3200
BacktrackVNXe seriesVNXe3100, VNXe3150, VNXe3300
BacktrackVNX seriesVNX 5100, VNX 5300, VNX 5500, VNX 5700, VNX 7500
Go to Top of "NDMP Families"

Dell EMC Isilon

BacktrackFamilyFamily Members
BacktrackScale-Out NASIQ Storage, IQ Storage HD-Series, IQ Storage NL-Series, IQ Storage S-Series, IQ Storage X-Series
Go to Top of "NDMP Families"

Hitachi

BacktrackFamilyFamily Members
BacktrackNAS Platform, 4000 and 3000 SeriesHNAS 3080 (M1), HNAS 3090 (M2), HNAS 4040, HNAS 4060, HNAS 4080, HNAS 4100
BacktrackNAS Platform F1000 (HNAS F1000)HNAS F1120, HNAS F1140
BacktrackVirtual File Platform (VFP)VFP 50, VFP 70, VFP 80, VFP 100N, VFP 110, VFP 200N, VFP 300N, VFP 500N, VFP 600N, VFP 2010, VFP 2100, VFP 2300
BacktrackVSP Gx00/Fx00 seriesVSP F350, VSP F370, VSP F400, VSP F600, VSP F700, VSP F800, VSP F900, VSP G130, VSP G150, VSP G200, VSP G350, VSP G370, VSP G400, VSP G600, VSP G700, VSP G800, VSP G900
Go to Top of "NDMP Families"

IBM

BacktrackFamilyFamily Members
BacktrackStorwize seriesFlashSystem V9000, SANVC(2145), Storwize V3500, Storwize V3700, Storwize V5000, Storwize V5010, Storwize V5020, Storwize V5030, Storwize V7000, Storwize V7000 Unified
BacktrackSystem Storage N seriesN3150, N3220, N3240, N3300, N3400, N3600, N3700, N5200, N5300, N5500, N5600, N6040, N6060, N6070, N6210, N6220, N6240, N6250, N6270, N7550T, N7600, N7700, N7750T, N7800, N7900, N7950T
Go to Top of "NDMP Families"

NetApp

BacktrackFamilyFamily Members
BacktrackFAS SeriesAll 'FAS' Models.
Go to Top of "NDMP Families"

Oracle

BacktrackFamilyFamily Members
BacktrackZFS Storage Appliance seriesZFS Storage 7110, ZFS Storage 7120, ZFS Storage 7210, ZFS Storage 7310, ZFS Storage 7320, ZFS Storage 7410, ZFS Storage 7420, ZFS Storage ZS3-2, ZFS Storage ZS3-4, ZFS Storage ZS4-4, ZFS Storage ZS5-2, ZFS Storage ZS5-4

NAS Sources

NAS Source support information is listed below. This information is organized by vendor manufacturer/model(s), minimum software required, and any other important notes or information relevant to the hardware and its compatibility.

NAS devices listed in this sections have been tested with Backup Exec as a result of formal joint business agreements and OEM relationships.

Hardware is selected and prioritized for certification based on market research and input from the field, including customer feedback. If a customer would like to have their hardware considered for inclusion on this HCL, simply submit the request via an email mailto:Backup_Exec_HCL@veritas.com . Requests will be reviewed by the appropriate Veritas Product Management team members for possible certification, with final decisions based on the overall fit with the product, target market, and frequency of request.

Go to Top of "NAS Sources"

Overland Storage

FamilyFamily MembersSoftware TestedTape SupportNotes
SnapServer DXSnapServer DX1, SnapServer DX2, XSR 120, XSR 40, XSD 40GOS 7.2.126SAS Client Side Dedup is not supported.

Snapshots are not supported on the file system.

Overland Storage support link for agent installation instructions. http://support.overlandstorage.com/jive/servlet/KbServlet/download/10414-102-3212/10400441-001.pdf

SAN Infrastructure Components

The SAN infrastructure components section of the HCL is split into three sections - traditional fibre channel infrastructure components, FCoE infrastructure, and iSCSI "solutions". The fibre channel and FCoE sections list possible components to be used interchangeably, whereas the iSCSI section lists SAN components to be used as a solution; a complete set of hardware from hardware or software initiator, through interconnect (if any), to storage device.

Fibre channel SANs: To verify support for tape libraries, or virtual tape libraries (VTL), refer to the column labelled "ESO" in the respective "Tape Libraries with Drives" or "Virtual Tape Libraries with Drives" sections.

Libraries or drives with an interface column of "SCSI" require an interface card or bridge to establish a connection to an FC switch. Please see the content below for supported devices.

Fibre Channel Infrastructure

This list of supported fibre-channel storage area network (SAN) components represents what has been tested in Veritas labs, or in Veritas-supervised partner labs. All the devices in your SAN must be on this supported device list. To ensure compatibility, Veritas, the device manufacturers, and the operating system vendor must support the combination of SAN devices.

To verify support for tape libraries, or virtual tape libraries (VTL), refer to the column labelled "ESO" in the respective "Tape Libraries with Drives" or "Virtual Tape Libraries with Drives" sections.

HBAs

Note: The OS and Version information indicate the tested platform. Unless specifically noted all other OS Versions are supported.

Veritas recommends (where possible), the following to avoid complications in the SAN environment:

1. Avoid mixing HBAs from different vendors.

2. All HBAs should use the same firmware, BIOS and driver revision.

3. Consult the hardware vendor's web site for up-to-date firmware and driver updates.

4. Where support is shown for Windows Server 2008, Windows Server 2012, or Windows Server 2016, please reference the Software Compatibility List ( http://www.veritas.com/docs/000115689) for supported operating system versions.

Go to Top of "HBAs"

Brocade

DeviceBus TypeWindows
425PCIeWindows Server 2008, Windows Server 2012
815PCIeWindows Server 2008
1860 (FC)PCIeWindows Server 2008
Go to Top of "HBAs"

Emulex

DeviceBus TypeWindows(Asianux Consortium) Asianux(Red Hat) Enterprise Linux(SUSE) SUSE Linux Enterprise Server
LP1100x / 1150 series (Helios ASIC) (members)PCI-XWindows Server 20082.04.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
LPe11xxx / 115x series (Zephyr ASIC) (members)PCIeWindows Server 20082.04.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10,
11
LPe12xxx / 125x series (Saturn ASIC) (members)PCIeWindows Server 2008, Windows Server 20122.04.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
LPe16xxx / 15xxx series (Lancer ASIC) (members)PCIeWindows Server 2008, Windows Server 2012, Windows Server 2016
Go to Top of "HBAs"

Hewlett Packard Enterprise

DeviceBus TypeWindows(Asianux Consortium) Asianux(Red Hat) Enterprise Linux(SUSE) SUSE Linux Enterprise Server
81BPCIeWindows Server 2008
81EPCIeWindows Server 20082.04.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
81QPCIeWindows Server 2008
82BPCIeWindows Server 2008
82EPCIeWindows Server 2008
82QPCIeWindows Server 2008
A7388APCI-XWindows Server 20082.04.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
AJ763APCIeWindows Server 2016
AJ764APCIeWindows Server 20084.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
FC1142SRPCIeWindows Server 20084.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
FC1143PCI-XWindows Server 20084.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
FC2142SRPCIeWindows Server 20082.04.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
FC2143PCIeWindows Server 20082.04.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
QMH2462-HP-BKPCIeWindows Server 2008
SN1000EPCIeWindows Server 2012
SN1000Q / SN1100Q series (members)PCIeWindows Server 2012
Go to Top of "HBAs"

Hitachi

DeviceBus TypeWindows
HFCE080x series (members)PCIe, mezzanineWindows Server 2008
Go to Top of "HBAs"

LSI Logic

DeviceBus TypeWindows
LSI7202XP-LCPCI-XWindows Server 2008
Go to Top of "HBAs"

QLogic

DeviceBus TypeWindows(Red Hat) Enterprise Linux(SUSE) SUSE Linux Enterprise Server
QLE236x series (members)PCIeWindows Server 2008, Windows Server 20124.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
QLE2400 series (members)PCIeWindows Server 2008, Windows Server 20124.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
QLE2500 series (members)PCIeWindows Server 2008, Windows Server 20124.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
QLE2600 series (members)PCIeWindows Server 2008, Windows Server 2012, Windows Server 2016, Windows Server 2019
QLE2670 series (members)PCIeWindows Server 2008, Windows Server 2012
QLE2690 series (members)PCIeWindows Server 2012
QLE2700 series (members)PCIeWindows Server 2012, Windows Server 2016
QLE8300 series (FC) (members)PCIeWindows Server 2012
QLE10000 series (members)PCIeWindows Server 2008
SANblade 23xx series (members)PCI, PCI-XWindows Server 2008, Windows Server 20124.0 (ES),
5.0 (Advanced),
5.0 (base)
9,
10
SANblade 24xx series (members)PCI-XWindows Server 2008, Windows Server 2012, Windows Server 20195.0 (base)
Go to Top of "HBAs"

Sun

DeviceBus TypeWindows
SG-XPCIE2FC-QF4PCIeWindows Server 2008

HBA Families

Emulex

BacktrackFamilyFamily Members
BacktrackLP1100x / 1150 series (Helios ASIC)LP1150, LP11000, LP11000-M4, LP11002, LP11002-M4, LP12002-S
BacktrackLPe11xxx / 115x series (Zephyr ASIC)LPe111, LPe1105-M, LPe1150, LPe11000, LPe11002, LPe11002-E, LPe11002-S, LPe11004, LPem11002-S
BacktrackLPe12xxx / 125x series (Saturn ASIC)LPe1205-HP, LPe1250, LPe12000, LPe12000-E, LPe12002, LPe12002-E, LPe12002-M8, LPe12002-X8, LPe12004
BacktrackLPe16xxx / 15xxx series (Lancer ASIC)LPe15004, LPe16000-M6, LPe16000B, LPe16000B-M6, LPe16000B-M8, LPe16002-M6, LPe16002B, LPe16002B-M6, LPe16002B-M8, LPe16004, LPe16202 (FC)

Hewlett Packard Enterprise

BacktrackFamilyFamily Members
BacktrackSN1000Q / SN1100Q seriesSN1000Q, SN1100Q

Hitachi

BacktrackFamilyFamily Members
BacktrackHFCE080x seriesHFCE0801, HFCE0802, HFCE0802-M, HFCE0804-M

QLogic

BacktrackFamilyFamily Members
BacktrackQLE236x seriesQLE2360, QLE2362
BacktrackQLE2400 seriesQLE2440, QLE2460, QLE2462, QLE2464, QME2462, QMI2572
BacktrackQLE2500 seriesQLE2560, QLE2562, QLE2562-S, QLE2564, QME2572, QMH2562, QMH2572, QMI2582, QMI3572
BacktrackQLE2600 seriesQLE2660, QLE2662
BacktrackQLE2670 seriesQLE2670, QLE2672
BacktrackQLE2690 seriesQLE2690, QLE2692, QLE2694, QLE2694L, QLE2694U
BacktrackQLE2700 seriesQLE2740, QLE2742, QLE2764
BacktrackQLE8300 series (FC)QLE8360 (FC), QLE8362 (FC)
BacktrackQLE10000 seriesQLE10502, QLE10522, QLE10542
BacktrackSANblade 23xx seriesQCP2332, QCP2340, QLA2300, QLA2302, QLA2310, QLA2332, QLA2340, QLA2340C, QLA2342, QLA2344, QSB2340, QSB2342
BacktrackSANblade 24xx seriesQLA2440, QLA2460, QLA2462

Bridges and Routers

Consult the hardware vendor's web site for up-to-date firmware updates.

Go to Top of "Bridges and Routers"

ADIC

Device
SNC 4000 (embedded)
Go to Top of "Bridges and Routers"

ATTO

Device
FibreBridge 3300
Go to Top of "Bridges and Routers"

Crossroads

Device
6000 [1]
  • f189-1
6240 Storage Router [1]
  • f189-1
  1. If hardware encryption is used, then a minimum firmware of 5.8.24 is required.
Go to Top of "Bridges and Routers"

Dell EMC

Device
PV-132T (FCR embedded)
Go to Top of "Bridges and Routers"

Hewlett Packard Enterprise

Device
e1200-320 4Gb
e2400-160 FC Interface Controller
e2400-FC 2Gb Interface Controller
e2400-FC 4Gb Interface Controller
Go to Top of "Bridges and Routers"

Qualstar

Device
FS1310B embedded router
VFS113 embedded router
VFS212 embedded router
Go to Top of "Bridges and Routers"

Quantum

Device
FC1202
FC470
Go to Top of "Bridges and Routers"

Spectra Logic

Device
F-QIP
Go to Top of "Bridges and Routers"

StorageTek

Device
Direct FC Attach (L180/L700)
L1400 Interface Control Module

Switches

1. Avoid mixing switches/hubs from different vendors, unless specifically supported by the switch/hub vendors.

2. Consult the hardware vendor's web site for up-to-date firmware updates.

Go to Top of "Switches"

Brocade

Device
300
5100
6510
G620
SilkWorm 12000
SilkWorm 200E
SilkWorm 2010
SilkWorm 2050
SilkWorm 220E
SilkWorm 240E
SilkWorm 300
SilkWorm 3200
SilkWorm 3250
SilkWorm 3800
SilkWorm 3850
SilkWorm 3900
SilkWorm 4100
SilkWorm 5100
SilkWorm 6505
Go to Top of "Switches"

Cisco Systems

Device
MDS9216
Go to Top of "Switches"

Hewlett Packard Enterprise

Device
4Gb Virtual Connect Fibre Channel Module for c- Class Bla
SAN Switch 4/16
SAN Switch 4/32
SAN Switch 4/64
SAN Switch 4/8
SAN Switch 8/24
SAN Switch 8/40
SAN Switch 8/8
SAN Switch 8/80
SAN Switch SN6000B 16GB 48/48
SAN Switch SN6600B 32Gb 48/48
Go to Top of "Switches"

IBM

Device
2109 F32
Go to Top of "Switches"

McDATA

Device
ED-5000
ES-3016
Sphereon 4500
Go to Top of "Switches"

QLogic

Device
SANbox 3602
SANbox 3810
SANbox 5600
SANbox 5602
SANbox 5800
SANbox 5802
SANbox 9000
SANbox 9008V

FCoE Infrastructure

This list of supported Fibre Channel over Ethernet (FCoE) storage area network (SAN) components represents what has been tested in Veritas labs, or in Veritas-supervised partner labs. All the devices in your SAN must be on this supported device list. To ensure compatibility, Veritas, the device manufacturers, and the operating system vendor must support the combination of SAN devices.

To verify support for tape libraries, or virtual tape libraries (VTL), refer to the column labelled "ESO" in the respective "Tape Libraries with Drives" or "Virtual Tape Libraries with Drives" sections.

CNAs

Please Note:

1. All like CNAs within a SAN should use the same firmware, BIOS and driver revision as recommended by CNA vendors.

2. Consult the hardware vendor's web site for current firmware and driver updates (where applicable).

3. Running a server's Ethernet and Fibre Channel over Ethernet (FCoE) traffic on the same CNA port is not supported.

4. Where support is shown for Windows Server 2008, Windows Server 2012,or Windows Server 2016 please reference the Software Compatibility List ( http://www.veritas.com/docs/000115689) for supported operating system versions.

Go to Top of "CNAs"

Brocade

DeviceBus TypeWindows
1860 (FCoE)PCIeWindows Server 2008
Go to Top of "CNAs"

Emulex

DeviceBus TypeWindows
OneConnect OCe11000 series (FCoE BE3 ASIC) (members)PCIeWindows Server 2008, Windows Server 2012
OneConnect OCe14000 series (FCoE Skyhawk ASIC) (members)PCIeWindows Server 2008, Windows Server 2012
OneConnect OCe14401 Series (FCoE Skyhawk ASIC) (members)PCIeWindows Server 2012
Go to Top of "CNAs"

Hewlett Packard Enterprise

DeviceBus TypeWindows(Red Hat) Enterprise Linux
554FLRPCIeWindows Server 2016
CN1000QPCIeWindows Server 20085.0 (base)
CN1100EPCIeWindows Server 20085.0 (base)
HP FlexFabric 10Gb 2-port 556FLR-SFP+ AdapterPCIe 2.0Windows Server 2012
NC553iPCIeWindows Server 20085.0 (base)
Go to Top of "CNAs"

QLogic

DeviceBus TypeWindows
QLE8200 series (FCoE) (members)PCIeWindows Server 2008
QLE8300 series (FCoE) (members)PCIeWindows Server 2008, Windows Server 2012
QLE8400 series (FCoE) (members)PCIeWindows Server 2008, Windows Server 2012

CNA Families

Emulex

BacktrackFamilyFamily Members
BacktrackOneConnect OCe11000 series (FCoE BE3 ASIC)OCe11102 (FCoE)
BacktrackOneConnect OCe14000 series (FCoE Skyhawk ASIC)OCe14102 (FCoE), OCm14102-OCP (FCoE)
BacktrackOneConnect OCe14401 Series (FCoE Skyhawk ASIC)OCe14401 (FCoE), OCe14401B (FCoE)

QLogic

BacktrackFamilyFamily Members
BacktrackQLE8200 series (FCoE)QLE8240 (FCoE), QLE8242 (FCoE)
BacktrackQLE8300 series (FCoE)QLE8360 (FCoE), QLE8362 (FCoE)
BacktrackQLE8400 series (FCoE)QLE8440 (FCoE), QLE8442 (FCoE)

Bridges and Routers

Go to Top of "Bridges and Routers"

Cisco Systems

Device
N5K-1008

Switches

Go to Top of "Switches"

Cisco Systems

Device
Nexus 5010
Go to Top of "Switches"

Hewlett Packard Enterprise

Device
2408 FCoE CN Switch

iSCSI Solutions

This list of tested iSCSI components represents what has been tested in Veritas labs, or in Veritas-supervised partner labs. The listed components in each row should be used together to ensure compatibility. This section is a mix of physical and virtual TAPE libraries. iSCSI disk solutions are listed in the appropriate Disk sections of this HCL.

Please Note:

1. Each column within the configuration tables represents the key components that were tested in an iSCSI SAN with the Backup Exec Enterprise Server Option (ESO).

2. To ensure compatibility, Veritas, the device manufacturers, and the operating system vendor must support the combination of iSCSI devices.

3. Configurations that use the Microsoft iSCSI initiator aren't supported with the Simplified Disaster Recovery (SDR) option.

4. The firmware and driver versions listed are minimum recommended levels. For device support and firmware/driver updates, please contact your hardware vendor.

5. Where possible, avoid mixing of vendor HBAs. All like HBAs within your SAN should use the same firmware, BIOS and driver revision.

6. In some cases, tape libraries with mixed media drive types were tested. Either drive type may be used.

7. The "ULTRIUM-TD" and the "ULT3580-TD" inquiry strings are interchangeable (both are supported), unless otherwise indicated. The "ULTRIUM-HH" and the "ULT3580-HH" inquiry strings are interchangeable (both are supported), unless otherwise indicated.

Go to Top of "iSCSI Solutions"

Amazon

Library ~ Firmware ~ InquiryDrive ~ Firmware ~ InquiryHBA ~ Driver ~ FirmwareInterconnect ~ Firmware
Amazon AWS Storage Gateway VTL ~ 16-Dec-2014 ~ AWS^^^^^Gateway-VTL [1]IBM TotalStorage 3580 Ultrium 5 ~ N/A ~ IBM^^^^^ULT3580-TD5Microsoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AAmazon AWS iSCSI device ~ N/A
  • f211-1
Amazon AWS Storage Gateway VTL ~ 16-Dec-2014 ~ AWS^^^^^Gateway-VTL [1]IBM TotalStorage 3580 Ultrium 5 ~ N/A ~ IBM^^^^^ULT3580-TD5Microsoft iSCSI Software Initiator ~ msiscsi.sys 6.2.9200.16813 - N/AAmazon AWS iSCSI device ~ N/A
  • f211-1
Amazon AWS Storage Gateway VTL ~ 16-Dec-2014 ~ AWS^^^^^Gateway-VTL [1]IBM TotalStorage 3580 Ultrium 5 ~ N/A ~ IBM^^^^^ULT3580-TD5Microsoft iSCSI Software Initiator ~ msiscsi.sys 6.3.9600.16384 - N/AAmazon AWS iSCSI device ~ N/A
  • f211-1
  1. This device includes Cloud features. Please see the Amazon Cloud Storage section for specifics.
Go to Top of "iSCSI Solutions"

BDT

Library ~ Firmware ~ InquiryDrive ~ Firmware ~ InquiryHBA ~ Driver ~ FirmwareInterconnect ~ Firmware
BDT RDStor ~ R1.03 ~ BDT^^^^^RDStor_T [1]Hewlett Packard Enterprise Ultrium 1840 LTO4 ~ N/A ~ HP^^^^^^Ultrium^4-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.0.6001.18000 - N/ABDT Direct iSCSI Device ~ N/A
  • f212-1
  1. To Import, insert the RDX media into the slot(s) and select Scan from Backup Exec. Due to the physical differences between the RDstor and a tape library, regular import jobs will result in error messages in the import job log.
Go to Top of "iSCSI Solutions"

Dell EMC

Library ~ Firmware ~ InquiryDrive ~ Firmware ~ InquiryHBA ~ Driver ~ FirmwareInterconnect ~ Firmware
Dell EMC PowerVault TL2000 ~ 6.60 ~ IBM^^^^^3573-TLIBM System Storage TS2230 Ultrium 3 Half Height ~ 73P9 ~ IBM^^^^^ULT3580-HH3Microsoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.3640 - 1.5Dell EMC TL24iSCSIxSAS ~ v1.00.02
Dell EMC PowerVault TL2000 ~ 6.60 ~ IBM^^^^^3573-TLIBM System Storage TS2250 Ultrium 5 Half Height ~ N/A ~ IBM^^^^^ULT3580-HH5Microsoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.3640 - 1.5Dell EMC TL24iSCSIxSAS ~ v1.00.02
Dell EMC PowerVault TL2000 ~ 6.60 ~ IBM^^^^^3573-TLIBM System Storage TS2340 Ultrium 4 ~ 74H6 ~ IBM^^^^^ULT3580-TD4Microsoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.3640 - 1.5Dell EMC TL24iSCSIxSAS ~ v1.00.02
Dell EMC PowerVault TL2000 ~ 6.60 ~ IBM^^^^^3573-TLIBM Ultrium 4 Half Height ~ 89B1 ~ IBM^^^^^ULTRIUM-HH4Microsoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.3640 - 1.5Dell EMC TL24iSCSIxSAS ~ v1.00.02
Dell EMC PowerVault TL4000 ~ 6.60 ~ IBM^^^^^3573-TLIBM System Storage TS2230 Ultrium 3 Half Height ~ 73P9 ~ IBM^^^^^ULT3580-HH3Microsoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.3640 - 1.5Dell EMC TL24iSCSIxSAS ~ v1.00.02
Dell EMC PowerVault TL4000 ~ 6.60 ~ IBM^^^^^3573-TLIBM System Storage TS2250 Ultrium 5 Half Height ~ N/A ~ IBM^^^^^ULT3580-HH5Microsoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.3640 - 1.5Dell EMC TL24iSCSIxSAS ~ v1.00.02
Dell EMC PowerVault TL4000 ~ 6.60 ~ IBM^^^^^3573-TLIBM System Storage TS2340 Ultrium 4 ~ 74H6 ~ IBM^^^^^ULT3580-TD4Microsoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.3640 - 1.5Dell EMC TL24iSCSIxSAS ~ v1.00.02
Dell EMC PowerVault TL4000 ~ 6.60 ~ IBM^^^^^3573-TLIBM Ultrium 4 Half Height ~ 89B1 ~ IBM^^^^^ULTRIUM-HH4Microsoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.3640 - 1.5Dell EMC TL24iSCSIxSAS ~ v1.00.02
Dell EMC PowerVault TL4000 ~ A.50 ~ IBM^^^^^3573-TLIBM System Storage TS2240 Ultrium 4 Half Height ~ B171 ~ IBM^^^^^ULT3580-HH4Microsoft iSCSI Software Initiator ~ N/A 6.1.7600.16385 - N/ADell EMC TL24iSCSIxSAS ~ v1.00.05
Dell EMC PowerVault TL4000 ~ A.50 ~ IBM^^^^^3573-TLIBM System Storage TS2250 Ultrium 5 Half Height ~ B171 ~ IBM^^^^^ULT3580-HH5Microsoft iSCSI Software Initiator ~ N/A 6.1.7600.16385 - N/ADell EMC TL24iSCSIxSAS ~ v1.00.05
Go to Top of "iSCSI Solutions"

H3C

Library ~ Firmware ~ InquiryDrive ~ Firmware ~ InquiryHBA ~ Driver ~ FirmwareInterconnect ~ Firmware
H3C CP3310 ~ N/A ~ HP^^^^^^D2DBS [1][2]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ N/A ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f214-1
  • f214-2
H3C CP3352 ~ N/A ~ HP^^^^^^D2DBS [1][2]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ N/A ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f214-1
  • f214-2
H3C CP3354 ~ N/A ~ HP^^^^^^D2DBS [1][2]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ N/A ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f214-1
  • f214-2
H3C CP5510 ~ N/A ~ HP^^^^^^D2DBS [1][2]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ N/A ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f214-1
  • f214-2
H3C CP5550 ~ N/A ~ HP^^^^^^D2DBS [1][2]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ N/A ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f214-1
  • f214-2
  1. Each VTL may only be assigned to a single server (no sharing), but the physical library may be connected to multiple servers.
  2. This VTL also supports HPE LTO2, LTO3, LTO4, and LTO5 tape drive emulation. These combinations are also supported.
Go to Top of "iSCSI Solutions"

Hewlett Packard Enterprise

Library ~ Firmware ~ InquiryDrive ~ Firmware ~ InquiryHBA ~ Driver ~ FirmwareInterconnect ~ Firmware
Hewlett Packard Enterprise D2D100 Series Backup System ~ kn6C-001.231 ~ HP^^^^^^D2DBS [1][2]Hewlett Packard Enterprise Ultrium 460 LTO2 ~ N/A ~ HP^^^^^^Ultrium^2-SCSIMicrosoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.1748 - 2.03Hewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-2
Hewlett Packard Enterprise D2D100 Series Backup System ~ kn77 ~ HP^^^^^^D2DBS [1][2]Hewlett Packard Enterprise Ultrium 460 LTO2 ~ N/A ~ HP^^^^^^Ultrium^2-SCSIMicrosoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.1748 - 2.03Hewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-2
Hewlett Packard Enterprise D2D100 Series Backup System ~ kn7b ~ HP^^^^^^D2DBS [1][2]Hewlett Packard Enterprise Ultrium 460 LTO2 ~ N/A ~ HP^^^^^^Ultrium^2-SCSIMicrosoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.1748 - 2.03Hewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-2
Hewlett Packard Enterprise D2D2500 Series Backup System ~ pf86 ~ HP^^^^^^D2DBS [1][3]Hewlett Packard Enterprise Ultrium 1840 LTO4 ~ N/A ~ HP^^^^^^Ultrium^4-SCSIMicrosoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.3640 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-3
Hewlett Packard Enterprise D2D4000 Series Backup System ~ pf86 ~ HP^^^^^^D2DBS [1][3]Hewlett Packard Enterprise Ultrium 1840 LTO4 ~ N/A ~ HP^^^^^^Ultrium^4-SCSIMicrosoft iSCSI Software Initiator ~ iscsiprt.sys 5.2.3790.3640 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-3
Hewlett Packard Enterprise StoreOnce 2700 ~ N/A ~ HP^^^^^^D2DBS [1][3]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ N/A ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-3
Hewlett Packard Enterprise StoreOnce 2900 ~ N/A ~ HP^^^^^^D2DBS [1][3]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ N/A ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-3
Hewlett Packard Enterprise StoreOnce 3000 ~ N/A ~ HP^^^^^^D2DBS [1][3]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ N/A ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-3
Hewlett Packard Enterprise StoreOnce 3500 ~ N/A ~ HP^^^^^^D2DBS [1][3]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ N/A ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-3
Hewlett Packard Enterprise StoreOnce 4000 ~ N/A ~ HP^^^^^^D2DBS [1][3]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ N/A ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-3
Hewlett Packard Enterprise StoreOnce 5000 ~ N/A ~ HP^^^^^^D2DBS [1][3]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ N/A ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-3
Hewlett Packard Enterprise StoreOnce VSA ~ EL01 ~ HP^^^^^^D2DBS [4][5][6][7]Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ ED51 ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 6.3.9600.17328 - N/AHewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-4
  • f215-5
  • f215-6
  • f215-7
Hewlett Packard Enterprise VLS 1000i ~ 2.6.0.226 ~ HP^^^^^^VLS1000i [1][8]Hewlett Packard Enterprise Ultrium 460 LTO2 ~ N/A ~ HP^^^^^^Ultrium^2-SCSIQLogic QLA4052C ~ N/A 2.1.2.0 - 2.0.0.7Hewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-8
Hewlett Packard Enterprise VLS 1000i ~ 2.6.0.228 ~ HP^^^^^^VLS1000i [1][8]Hewlett Packard Enterprise Ultrium 460 LTO2 ~ N/A ~ HP^^^^^^Ultrium^2-SCSIQLogic QLA4052C ~ ql40xx.sys 2.1.3.26 - 2.0.0.7Hewlett Packard Enterprise Direct iSCSI Device ~ N/A
  • f215-1
  • f215-8
  1. Each VTL may only be assigned to a single server (no sharing), but the physical library may be connected to multiple servers.
  2. Minimum VTL software version kn7b is required to support automated robotic import/export functionality.
  3. This VTL also supports HPE LTO2, LTO3, LTO4, and LTO5 tape drive emulation. These combinations are also supported.
  4. Each VTL may only be assigned to a single server (no sharing).
  5. For device details and platform support refer to: http://www8.hp.com/h20195/v2/GetDocument.aspx?docname=c04328820
  6. StoreOnce VSA is a virtual appliance supported on VMware 5.x
  7. StoreOnce VSA is a virtual appliance supported on Windows Server 2012 Hyper-V R2
  8. Both the "VLS1000i" and "VLS1002i" models are supported. The difference is in the capacity.
Go to Top of "iSCSI Solutions"

Overland Storage

Library ~ Firmware ~ InquiryDrive ~ Firmware ~ InquiryHBA ~ Driver ~ FirmwareInterconnect ~ Firmware
Overland Storage REO 4600 ~ N/A ~ OVERLANDREO^SeriesHewlett Packard Enterprise Ultrium 460 LTO2 ~ N/A ~ HP^^^^^^Ultrium^2-SCSIMicrosoft iSCSI Software Initiator ~ msiscsi.sys 5.2.3790.3497 - N/AOverland Storage Direct iSCSI Device ~ N/A
Go to Top of "iSCSI Solutions"

Quantum

Library ~ Firmware ~ InquiryDrive ~ Firmware ~ InquiryHBA ~ Driver ~ FirmwareInterconnect ~ Firmware
Quantum RDX8000 ~ R1.08 ~ QUANTUM^RDX8000_T [1]Quantum LTO-4 ~ N/A ~ QUANTUM^ULTRIUM^4Microsoft iSCSI Software Initiator ~ msiscsi.sys 6.0.6001.18000 - N/AQuantum Direct iSCSI Device ~ N/A
  • f217-1
Quantum Scalar i40 ~ 120G ~ QUANTUM^Scalar^i40-i80Hewlett Packard Enterprise Ultrium 3000 LTO5 ~ Y23Z ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ N/A 6.1.7600.16385 - N/AChelsio USR1100-ESAS-FB ~ USR_v2.0.1
Quantum Scalar i500 ~ 586G ~ Quantum^Scalar^i500Hewlett Packard Enterprise Ultrium 3280 LTO5 ~ X38Z ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ N/A 6.1.7600.16385 - N/AChelsio USR1100-ESAS-FB ~ USR_v2.0.1
Quantum Scalar i80 ~ 120G ~ QUANTUM^Scalar^i40-i80Hewlett Packard Enterprise Ultrium 3000 LTO5 ~ Y23Z ~ HP^^^^^^Ultrium^5-SCSIMicrosoft iSCSI Software Initiator ~ N/A 6.1.7600.16385 - N/AChelsio USR1100-ESAS-FB ~ USR_v2.0.1
  1. To Import, insert the RDX media into the slot(s) and select "Scan" from Backup Exec. Due to the physical design of the RDX8000, regular Backup Exec import jobs will result in error messages in the import job log.
Go to Top of "iSCSI Solutions"

Quest

Library ~ Firmware ~ InquiryDrive ~ Firmware ~ InquiryHBA ~ Driver ~ FirmwareInterconnect ~ Firmware
Quest DR4000 (Dell) ~ 0104 ~ DELL^^^^DR_L700 [1][2]IBM TotalStorage 3580 Ultrium 4 ~ 0104 ~ IBM^^^^^ULT3580-TD4Microsoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AQuest Direct iSCSI Device ~ N/A
  • f218-1
  • f218-2
Quest DR4100 (Dell) ~ 0104 ~ DELL^^^^DR_L700 [1][2][3]IBM TotalStorage 3580 Ultrium 4 ~ 0104 ~ IBM^^^^^ULT3580-TD4Microsoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AQuest Direct iSCSI Device ~ N/A
  • f218-1
  • f218-2
  • f218-3
Quest DR4300 ~ 4.0 ~ QUEST^^^DR_L700 [1][4][5][6]IBM TotalStorage 3580 Ultrium 4 ~ 0104 ~ IBM^^^^^ULT3580-TD4Microsoft iSCSI Software Initiator ~ N/A 6.3.9600.18728 - N/AQuest Direct iSCSI Device ~ N/A
  • f218-1
  • f218-4
  • f218-5
  • f218-6
Quest DR4300 (Dell) ~ 0104 ~ DELL^^^^DR_L700 [1][2][7]IBM TotalStorage 3580 Ultrium 4 ~ 0104 ~ IBM^^^^^ULT3580-TD4Microsoft iSCSI Software Initiator ~ msiscsi.sys 6.1.7601.18386 - N/AQuest Direct iSCSI Device ~ N/A
  • f218-1
  • f218-2
  • f218-7
  1. Each VTL may only be assigned to a single server (no sharing).
  2. Minimum DR software of 3.2.0.1 is required.
  3. The DR6000 is also supported as a member of the 12g family.
  4. Minimum DR software of 4.0.2 is required for the Quest inquiry string.
  5. Please see the Quest Migration Guide https://support.quest.com/download/downloads?id=6084223
  6. The DR4000, DR4100, DR4300e, DR6000 and DR6300 are also supported using the Quest inquiry string.
  7. The DR4300e and DR6300 are also supported as members of the 13g family.
Go to Top of "iSCSI Solutions"

StorageTek

Library ~ Firmware ~ InquiryDrive ~ Firmware ~ InquiryHBA ~ Driver ~ FirmwareInterconnect ~ Firmware
StorageTek SL500 ~ 1048 ~ STK^^^^^SL500IBM TotalStorage 3580 Ultrium 3 ~ 5BG2 ~ IBM^^^^^ULT3580-TD3QLogic QLA4050C ~ ql40xx.sys 2.1.2.5 - 2.0.0.7QLogic SANbox 6140 ~ 2.0.7.2d
StorageTek SL500 ~ 1048 ~ STK^^^^^SL500IBM TotalStorage 3580 Ultrium 3 ~ 5BG2 ~ IBM^^^^^ULT3580-TD3QLogic QLA4050C ~ ql40xx.sys 2.1.2.5 - 2.0.0.7QLogic SANbox 6142 ~ 2.1.4.0a
Go to Top of "iSCSI Solutions"

Tandberg

Library ~ Firmware ~ InquiryDrive ~ Firmware ~ InquiryHBA ~ Driver ~ FirmwareInterconnect ~ Firmware
Tandberg DPS1100 VTL ~ 0363 ~ TANDBERGDPS1000 [1]Hewlett Packard Enterprise Ultrium 960 LTO3 ~ G39W ~ HP^^^^^^Ultrium^3-SCSIMicrosoft iSCSI Software Initiator ~ e1g60i32.sys 6.0.6002 - N/ATandberg Direct iSCSI Device ~ N/A
  • f220-1
Tandberg DPS1200 VTL ~ 0363 ~ TANDBERGDPS1000 [1]Hewlett Packard Enterprise Ultrium 960 LTO3 ~ G39W ~ HP^^^^^^Ultrium^3-SCSIMicrosoft iSCSI Software Initiator ~ e1g60i32.sys 6.0.6002 - N/ATandberg Direct iSCSI Device ~ N/A
  • f220-1
Tandberg RDX QuikStation ~ 0111 ~ TANDBERGQuikStation [2][3][4]Hewlett Packard Enterprise Ultrium 960 LTO3 ~ D237 ~ HP^^^^^^Ultrium^3-SCSIMicrosoft iSCSI Software Initiator ~ e1g6030e.sys 6.0.6002 - N/ATandberg Direct iSCSI Device ~ N/A
  • f220-2
  • f220-3
  • f220-4
Tandberg RDX QuikStation ~ 0210 ~ TANDBERGQuikStation [2][3][4]Hewlett Packard Enterprise Ultrium 960 LTO3 ~ D237 ~ HP^^^^^^Ultrium^3-SCSIMicrosoft iSCSI Software Initiator ~ N/A 6.1.7601.17514 - N/ATandberg Direct iSCSI Device ~ N/A
  • f220-2
  • f220-3
  • f220-4
Tandberg RDX QuikStation 4 ~ N/A ~ TANDBERGQuikStation [2][3][4]Hewlett Packard Enterprise Ultrium 960 LTO3 ~ D237 ~ HP^^^^^^Ultrium^3-SCSIMicrosoft iSCSI Software Initiator ~ N/A 6.1.7601.17514 - N/ATandberg Direct iSCSI Device ~ N/A
  • f220-2
  • f220-3
  • f220-4
Tandberg RDX QuikStation 8 ~ 01.003.02 ~ TANDBERGQuikStation [2][3][4]Hewlett Packard Enterprise Ultrium 960 LTO3 ~ D237 ~ HP^^^^^^Ultrium^3-SCSIMicrosoft iSCSI Software Initiator ~ N/A 6.1.7601.17514 - N/ATandberg Direct iSCSI Device ~ N/A
  • f220-2
  • f220-3
  • f220-4
  1. Each VTL may only be assigned to a single server (no sharing), but the physical library may be connected to multiple servers.
  2. See the referenced document for more details. ( http://www.veritas.com/docs/000012392 )
  3. The VTL may only be assigned to a single server (no sharing).
  4. This VTL has been validated as a backup device for use with VMware.

Retiring Soon

The devices in this section will not be listed as supported in the Hardware Compatibility List for the next major Backup Exec release after Backup Exec 15. Many of these devices are end-of-life products that are no longer supported by the manufacturer. This is a prediction, subject to frequent change, until the next version is actually released. This section is primarily for your education only as IT HAS NO DIRECT IMPACT ON YOUR CURRENT SUPPORTABILITY.

If this list contains a device you are actively using and are concerned about lack of support, please email mailto:Backup_Exec_HCL@veritas.com with details of the specific device you are using.

Retiring Disk Storage

Go to Top of "Retiring Disk Storage"

Imation

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
DataGuard AppliancesCIFSSR4, T5R
DataGuard AppliancesiSCSIR4, T5R
Go to Top of "Retiring Disk Storage"

Nexsan

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
Beast SystemsFibre ChannelSASBeast, SATABeast, SATABeast2
Beast SystemsiSCSISASBeast, SATABeast, SATABeast2
Boy SystemsFibre ChannelSASBoy, SATABoy2
Boy SystemsiSCSISASBoy, SATABoy2
SATABoyFibre ChannelSATABoy
SATABoyiSCSISATABoy

Retiring OST-Appliance

This OST section contains rows that frequently indicate that support for a plug-in will expire in the next version of Backup Exec, per the OST vendor's request. Please do not assume that support for the entire device is withdrawn. Your OST device and OST plug-in version probably just need to be updated.

Go to Top of "Retiring OST-Appliance"

Dell EMC

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Supported OpenStorage Functionality
DR SeriesDR4000, DR4100, DR60003.2EthernetBasic Deduplication, Optimized Duplication
Go to Top of "Retiring OST-Appliance"

Dell EMC Data Domain

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Windows Server 2016Supported OpenStorage Functionality
Appliance seriesDD140, DD160, DD510, DD530, DD560, DD565, DD580, DD610, DD620, DD630, DD640, DD660, DD670, DD690, DD860, DD880, DD890, DD990, DD2200, DD2500, DD3300, DD4200, DD4500, DD6300, DD6800, DD7200, DD9300, DD9500, DD98003.1EthernetBasic Deduplication, Optimized Duplication
Virtual Edition (VMware)Virtual Edition (VMware)3.1EthernetBasic Deduplication, Optimized Duplication
Go to Top of "Retiring OST-Appliance"

H3C

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Supported OpenStorage Functionality
CP3310CP33102.0EthernetBasic Deduplication, Optimized Duplication
CP3352CP33522.0EthernetBasic Deduplication, Optimized Duplication
CP3354CP33542.0EthernetBasic Deduplication, Optimized Duplication
CP5510CP55102.0EthernetBasic Deduplication, Optimized Duplication
CP5550CP55502.0EthernetBasic Deduplication, Optimized Duplication
CP6660CP66602.0EthernetBasic Deduplication, Optimized Duplication
Go to Top of "Retiring OST-Appliance"

Hewlett Packard Enterprise

Storage Server FamilyStorage Server Family MembersPlug-inData InterfaceWindows Server 2008Windows Server 2012Windows Server 2016Supported OpenStorage Functionality
StoreOnce 2000 seriesStoreOnce 2610, StoreOnce 2620, StoreOnce 2700, StoreOnce 29002.0EthernetBasic Deduplication, Optimized Duplication
StoreOnce 3000 seriesStoreOnce 31002.0EthernetBasic Deduplication, Optimized Duplication
StoreOnce 3500/3600 seriesStoreOnce 3520, StoreOnce 3540, StoreOnce 3620, StoreOnce 36402.0EthernetBasic Deduplication, Optimized Duplication
StoreOnce 4000 seriesStoreOnce 4210fc, StoreOnce 4210i, StoreOnce 4220, StoreOnce 4420, StoreOnce 4430, StoreOnce 4500, StoreOnce 4700, StoreOnce 49002.0EthernetBasic Deduplication, Optimized Duplication
StoreOnce 5000 seriesStoreOnce 5100, StoreOnce 5200, StoreOnce 5250, StoreOnce 5500, StoreOnce 56502.0EthernetBasic Deduplication, Optimized Duplication
StoreOnce 6000 seriesStoreOnce 6500, StoreOnce 6600, StoreOnce B62002.0EthernetBasic Deduplication, Optimized Duplication
StoreOnce VSA (Hyper-V)StoreOnce VSA (Hyper-V)2.0EthernetBasic Deduplication, Optimized Duplication
StoreOnce VSA (VMware)StoreOnce VSA (VMware)2.0EthernetBasic Deduplication, Optimized Duplication

Retiring Virtual Tape Libraries with Drives

Go to Top of "Retiring Virtual Tape Libraries with Drives"

IBM

DeviceLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
Virtualization Engine TS7530Fibre ChannelIBMSystem Storage TS2340 Ultrium 4IBM^^^^^TS7530
IBM^^^^^ULT3580-TD4

Retiring NDMP Platforms

Go to Top of "Retiring NDMP Platforms"

Dell EMC

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
Compellent FS8600FluidFS 2.0Remote
Compellent FS8600FluidFS 3.0Remote
EqualLogic FS7500Scalable File System 1.0Remote
EqualLogic FS7500FluidFS 2.0Remote
EqualLogic FS7500FluidFS 3.0Remote
EqualLogic FS7600FluidFS 2.0Remote
EqualLogic FS7600FluidFS 3.0Remote
EqualLogic FS7610FluidFS 2.0Remote
EqualLogic FS7610FluidFS 3.0Remote
PowerVault NX3500Scalable File System 1.0Remote
PowerVault NX3500FluidFS 2.0Remote
PowerVault NX3500FluidFS 3.0Remote
PowerVault NX3600FluidFS 2.0Remote
PowerVault NX3600FluidFS 3.0Remote
PowerVault NX3610FluidFS 2.0Remote
PowerVault NX3610FluidFS 3.0Remote
Go to Top of "Retiring NDMP Platforms"

IBM

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
System Storage N series (members)Data ONTAP 7.2.3Direct Attach, Remote, 3-way
System Storage N series (members)Data ONTAP 7.3.6Direct Attach, Remote, 3-way
System Storage N series (members)Data ONTAP v8.0 (7-Mode)Direct Attach, Remote, 3-way
System Storage N series (members)Data ONTAP v8.0 (Cluster-Mode)Direct Attach, Remote, 3-way
System Storage N series (members)Data ONTAP v8.1 (7-Mode)Direct Attach, Remote, 3-way
System Storage N series (members)Data ONTAP v8.1 (Cluster-Mode)Direct Attach, Remote, 3-way
System Storage N series (members)Data ONTAP v8.1.2 (7-Mode)Direct Attach, Remote, 3-way
System Storage N series (members)Data ONTAP v8.1.2 (Cluster-Mode)Direct Attach, Remote, 3-way
System Storage N series (members)Data ONTAP v8.1.3 (7-Mode)Direct Attach, Remote, 3-way
System Storage N series (members)Data ONTAP v8.1.3 (Cluster-Mode)Direct Attach, Remote, 3-way
System Storage N series (members)Data ONTAP v8.1.4 (7-Mode)Direct Attach, Remote, 3-way
System Storage N series (members)Data ONTAP v8.1.4 (Cluster-Mode)Direct Attach, Remote, 3-way
Go to Top of "Retiring NDMP Platforms"

NetApp

DeviceSoftware TestedConnection MethodDirect Access RestoreDirectory Direct Access RestoreESO
FAS Series (members)Data ONTAP v7.0.3Direct Attach, Remote, 3-way
FAS Series (members)Data ONTAP v7.2.3Direct Attach, Remote, 3-way
FAS Series (members)Data ONTAP v7.3.1Direct Attach, Remote, 3-way
FAS Series (members)Data ONTAP v7.3.6Direct Attach, Remote, 3-way
FAS Series (members)Data ONTAP v8.0 (7-Mode)Direct Attach, Remote, 3-way
FAS Series (members)Data ONTAP v8.0 (Cluster-Mode)Direct Attach, Remote, 3-way

Support End-of-Life

EOL Notice: These devices are no longer officially supported for use with this version of Backup Exec. This is a periodic process to bring Backup Exec support in line with what is still supported by the hardware vendors and/or the device's age, capacity or performance. Please be aware that different vendors may have different EOL policies for their particular model of a common device. See the HCL introduction for further clarification of our policies and goals. No changes were made to Backup Exec to drop support or recognition for these devices, so it is fully expected that they will continue to work with this version of Backup Exec. But if a problem is discovered with the device, it is likely that vendor support, repair parts, and/or firmware fixes are no longer available which limits the ability of our Veritas technical support team to help resolve your issue. Please be aware that Windows 2008 (and newer) treats some devices (especially ATAPI/IDE/SATA) different than Windows 2003 did, so if you are moving old hardware to a new server, the operating system change may have more of an impact than changing versions of Backup Exec.

OST Note: The OST section contains rows that frequently indicate that support for a plug-in has expired, per the OST vendor's request. Please do not assume that support for the entire device is withdrawn. Your OST device and OST plug-in version probably just need to be updated.

End-of-Life Tape Drives

Go to Top of "End-of-Life Tape Drives"

Dell EMC

DeviceInquiry StringDrive Interface
PowerVault 100T DAT72SEAGATE^DAT^DAT72SCSI
PowerVault 110T LTO2 (Gen2 IBM)IBM^^^^^ULTRIUM-TD2SCSI
PowerVault 110T LTO3 (IBM)IBM^^^^^ULTRIUM-TD3SCSI
PowerVault 110T VS160QUANTUM^DLT^VS160SCSI
PowerVault 112T seriesvariesSCSI
PowerVault 114T seriesvariesSAS
PowerVault 114T seriesvariesSCSI
PowerVault LTO3-060 (IBM)IBM^^^^^ULTRIUM-HH3SAS
PowerVault LTO3-060 (IBM)IBM^^^^^ULTRIUM-HH3SCSI
PowerVault LTO3-060 (Quantum)QUANTUM^ULTRIUM^3SAS
PowerVault LTO3-060 (Quantum)QUANTUM^ULTRIUM^3SCSI
PowerVault LTO3-080 (IBM)IBM^^^^^ULTRIUM-HH3SAS
Go to Top of "End-of-Life Tape Drives"

Hewlett Packard Enterprise

DeviceInquiry StringDrive Interface
DAT 72HP^^^^^^C7438ASCSI
DAT 72HP^^^^^^C7438AUSB 2.0
Ultrium 448 LTO2HP^^^^^^Ultrium^2-SCSISAS
Ultrium 448 LTO2HP^^^^^^Ultrium^2-SCSISCSI
Ultrium 460 LTO2HP^^^^^^Ultrium^2-SCSIFibre Channel
Ultrium 460 LTO2HP^^^^^^Ultrium^2-SCSISCSI
Ultrium 960 LTO3HP^^^^^^Ultrium^3-SCSIFibre Channel
Ultrium 960 LTO3HP^^^^^^Ultrium^3-SCSISCSI
Go to Top of "End-of-Life Tape Drives"

IBM

DeviceInquiry StringDrive Interface
TotalStorage 3580 Ultrium 1IBM^^^^^ULT3580-TD1SCSI
TotalStorage 3580 Ultrium 2IBM^^^^^ULT3580-TD2Fibre Channel
TotalStorage 3580 Ultrium 2IBM^^^^^ULT3580-TD2SCSI
Ultrium 1IBM^^^^^ULTRIUM-TD1SCSI
Ultrium 2IBM^^^^^ULTRIUM-TD2Fibre Channel
Ultrium 2IBM^^^^^ULTRIUM-TD2SCSI
Go to Top of "End-of-Life Tape Drives"

Quantum

DeviceInquiry StringDrive Interface
DAT 160QUANTUM^DAT^^^DAT160SAS
DAT 160QUANTUM^DAT^^^DAT160SCSI
DAT 160QUANTUM^DAT^^^DAT160USB 2.0
DAT 320QUANTUM^DAT^^^DAT320-000USB 2.0
DLT-S4QUANTUM^DLT-S4Fibre Channel
DLT-S4QUANTUM^DLT-S4SCSI
DLT-V4QUANTUM^DLT-V4SATA
DLT-V4QUANTUM^DLT-V4SCSI
DLT VS160QUANTUM^DLT^VS160SCSI
Go to Top of "End-of-Life Tape Drives"

Tandberg

DeviceInquiry StringDrive Interface
240LTOIBM^^^^^ULTRIUM-TD1SCSI
440LTOIBM^^^^^ULTRIUM-TD2SCSI
DAT 72HP^^^^^^C7438ASCSI
DAT 72HP^^^^^^C7438AUSB 2.0
HH LTO 2TANDBERGLTO-2^HHSAS
HH LTO 2TANDBERGLTO-2^HHSCSI

End-of-Life Tape Libraries with Drives

Go to Top of "End-of-Life Tape Libraries with Drives"

actidata

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
actiLib seriesSCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^2-SCSI
Go to Top of "End-of-Life Tape Libraries with Drives"

ADIC

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
Scalar i2000Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelADIC^^^^Scalar^i2000
HP^^^^^^Ultrium^3-SCSI
Scalar i2000Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelADIC^^^^Scalar^i2000
HP^^^^^^Ultrium^4-SCSI
Scalar i2000Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelADIC^^^^Scalar^i2000
IBM^^^^^ULT3580-TD3
Scalar i2000Fibre ChannelIBMUltrium 3Fibre ChannelADIC^^^^Scalar^i2000
IBM^^^^^ULTRIUM-TD3
Scalar i2000Fibre ChannelIBMUltrium 4Fibre ChannelADIC^^^^Scalar^i2000
IBM^^^^^ULTRIUM-TD4
Scalar i2000Fibre ChannelQuantumDLT-S4Fibre ChannelADIC^^^^Scalar^i2000
QUANTUM^DLT-S4
Go to Top of "End-of-Life Tape Libraries with Drives"

BDT

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
FlexStor IISCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIBDT^^^^^FlexStor^II
HP^^^^^^Ultrium^2-SCSI
ThinStorPlusSCSIIBMTotalStorage 3580 Ultrium 2SCSIBDT^^^^^ThinStorPlus^AL
IBM^^^^^ULT3580-TD2
ThinStorPlus SM2SCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIBDT^^^^^ThinStorPlus^SM2
HP^^^^^^Ultrium^2-SCSI
Go to Top of "End-of-Life Tape Libraries with Drives"

Dell EMC

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
PowerVault 124TSCSIDell EMCPowerVault LTO3-060 (Quantum)SCSIDELL^^^^PV-124T
QUANTUM^ULTRIUM^3
Go to Top of "End-of-Life Tape Libraries with Drives"

Fujitsu

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
FibreCAT TX08SCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIFSC^^^^^FibreCAT^TX08
HP^^^^^^Ultrium^2-SCSI
FibreCAT TX24SCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIFSC^^^^^FibreCAT^TX24
HP^^^^^^Ultrium^2-SCSI
FibreCAT TX48SCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIFSC^^^^^FibreCAT^TX48
HP^^^^^^Ultrium^2-SCSI
Go to Top of "End-of-Life Tape Libraries with Drives"

Hewlett Packard Enterprise

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
1/8 G2 Tape AutoloaderSCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIHP^^^^^^1x8^G2^AUTOLDR
HP^^^^^^Ultrium^2-SCSI
DAT 72x10SCSIHewlett Packard EnterpriseDAT 72SCSIHP^^^^^^DAT^Autoloader
HP^^^^^^C7438A
ESL E-SeriesFibre ChannelHewlett Packard EnterpriseUltrium 460 LTO2Fibre ChannelHP^^^^^^ESL^E-Series
HP^^^^^^Ultrium^2-SCSI
ESL E-SeriesFibre ChannelHewlett Packard EnterpriseUltrium 460 LTO2SCSIHP^^^^^^ESL^E-Series
HP^^^^^^Ultrium^2-SCSI
ESL E-SeriesFibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelHP^^^^^^ESL^E-Series
HP^^^^^^Ultrium^3-SCSI
ESL E-SeriesFibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelHP^^^^^^ESL^E-Series
HP^^^^^^Ultrium^4-SCSI
ESL E-SeriesFibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelHP^^^^^^ESL^E-Series
HP^^^^^^Ultrium^5-SCSI
ESL E-SeriesSCSIHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelHP^^^^^^ESL^E-Series
HP^^^^^^Ultrium^3-SCSI
MSL2024/4048/8048/8096 (G3 series)SCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^2-SCSI
MSL2024/4048/8048/8096 (G3 series)SCSIHewlett Packard EnterpriseUltrium 460 LTO2SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^2-SCSI
MSL6000 SeriesSCSIHewlett Packard EnterpriseUltrium 460 LTO2SCSIHP^^^^^^MSL6000^Series
HP^^^^^^Ultrium^2-SCSI
MSL6000 SeriesSCSIHewlett Packard EnterpriseUltrium 960 LTO3SCSIHP^^^^^^MSL6000^Series
HP^^^^^^Ultrium^3-SCSI
MSL6000 SeriesSCSIHewlett Packard EnterpriseUltrium 1840 LTO4SCSIHP^^^^^^MSL6000^Series
HP^^^^^^Ultrium^4-SCSI
Go to Top of "End-of-Life Tape Libraries with Drives"

IBM

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
System Storage TS3500 (Machine Type 3584)Fibre ChannelIBMTotalStorage 3580 Ultrium 2Fibre ChannelIBM^^^^^03584
IBM^^^^^ULT3580-TD2
Go to Top of "End-of-Life Tape Libraries with Drives"

Qualstar

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
TLS-8000 LTO seriesFibre ChannelIBMTotalStorage 3580 Ultrium 2Fibre ChannelQUALSTARTLS-8
IBM^^^^^ULT3580-TD2
TLS-8000 LTO seriesSCSIIBMTotalStorage 3580 Ultrium 2SCSIQUALSTARTLS-8
IBM^^^^^ULT3580-TD2
Go to Top of "End-of-Life Tape Libraries with Drives"

Quantum

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
Scalar i500Fibre ChannelIBMTotalStorage 3580 Ultrium 2Fibre ChannelQuantum^Scalar^i500
IBM^^^^^ULT3580-TD2
Scalar i500SCSIIBMTotalStorage 3580 Ultrium 3SCSIQuantum^Scalar^i500
IBM^^^^^ULT3580-TD3
Scalar i500SCSIIBMUltrium 4 (U160)SCSIQuantum^Scalar^i500
IBM^^^^^ULTRIUM-TD4
Scalar i2000Fibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3Fibre ChannelQuantum^Scalar^i2000
HP^^^^^^Ultrium^3-SCSI
Scalar i2000Fibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4Fibre ChannelQuantum^Scalar^i2000
HP^^^^^^Ultrium^4-SCSI
Scalar i2000Fibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5Fibre ChannelQuantum^Scalar^i2000
HP^^^^^^Ultrium^5-SCSI
Scalar i2000Fibre ChannelIBMTotalStorage 3580 Ultrium 3Fibre ChannelQuantum^Scalar^i2000
IBM^^^^^ULT3580-TD3
Scalar i2000Fibre ChannelIBMUltrium 4Fibre ChannelQuantum^Scalar^i2000
IBM^^^^^ULTRIUM-TD4
Scalar i6000Fibre ChannelIBMTotalStorage 3580 Ultrium 2Fibre ChannelQuantum^Scalar^i6000
IBM^^^^^ULT3580-TD2
Scalar i6000Fibre ChannelQuantumDLT-S4Fibre ChannelQuantum^Scalar^i6000
QUANTUM^DLT-S4
SuperLoader 3SCSIQuantumDLT-S4SCSIQUANTUM^UHDL
QUANTUM^DLT-S4
SuperLoader 3SCSIQuantumLTO-3 HHSCSIQUANTUM^UHDL
QUANTUM^ULTRIUM^3
Go to Top of "End-of-Life Tape Libraries with Drives"

Spectra Logic

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
T-seriesSCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSISPECTRA^PYTHON
HP^^^^^^Ultrium^2-SCSI
Go to Top of "End-of-Life Tape Libraries with Drives"

StorageTek

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
SL500Fibre ChannelHewlett Packard EnterpriseUltrium 460 LTO2Fibre ChannelSTK^^^^^SL500
HP^^^^^^Ultrium^2-SCSI
SL500Fibre ChannelIBMTotalStorage 3580 Ultrium 2Fibre ChannelSTK^^^^^SL500
IBM^^^^^ULT3580-TD2
SL500SCSIHewlett Packard EnterpriseUltrium 460 LTO2Fibre ChannelSTK^^^^^SL500
HP^^^^^^Ultrium^2-SCSI
SL500SCSIHewlett Packard EnterpriseUltrium 460 LTO2SCSISTK^^^^^SL500
HP^^^^^^Ultrium^2-SCSI
SL500SCSIIBMTotalStorage 3580 Ultrium 2Fibre ChannelSTK^^^^^SL500
IBM^^^^^ULT3580-TD2
SL500SCSIIBMTotalStorage 3580 Ultrium 2SCSISTK^^^^^SL500
IBM^^^^^ULT3580-TD2
Go to Top of "End-of-Life Tape Libraries with Drives"

Sun

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
StorageTek SL24SCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^2-SCSI
StorageTek SL48SCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIHP^^^^^^MSL^G3^Series
HP^^^^^^Ultrium^2-SCSI
StorageTek SL500SCSIIBMTotalStorage 3580 Ultrium 2SCSISTK^^^^^SL500
IBM^^^^^ULT3580-TD2
Go to Top of "End-of-Life Tape Libraries with Drives"

Tandberg

DeviceLibrary InterfaceDrive Mfr.Drive ModelDrive InterfaceLibrary Inquiry
Drive Inquiry
StorageLibrary T24SCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIEXABYTE^MAGNUM^224
HP^^^^^^Ultrium^2-SCSI
StorageLibrary T48SCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIEXABYTE^MAGNUM^448
HP^^^^^^Ultrium^2-SCSI
StorageLoader 2U LTOSCSIHewlett Packard EnterpriseUltrium 448 LTO2SCSIEXABYTE^MAGNUM^224
HP^^^^^^Ultrium^2-SCSI

End-of-Life Disk Storage

Go to Top of "End-of-Life Disk Storage"

Quantum

FamilyConnectivityBasic B2DGRT TestedDevicesBEDedup
DXi4000 SeriesCIFSSDXi4510, DXi4520, DXi4601
DXi5500CIFSSDXi5500
DXi6000 SeriesCIFSSDXi6510, DXi6520, DXi6530, DXi6540, DXi6550
DXi7500 SeriesCIFSSDXi7500 Enterprise, DXi7500 Express, DXi7500-N

End-of-Life Virtual Tape Libraries with Drives

Go to Top of "End-of-Life Virtual Tape Libraries with Drives"

Hewlett Packard Enterprise

DeviceLibrary InterfaceDrive Mfr.Drive ModelLibrary Inquiry
Drive Inquiry
D2D4300 G2 Series Backup SystemFibre ChannelHewlett Packard EnterpriseUltrium 3280 LTO5HP^^^^^^D2DBS
HP^^^^^^Ultrium^5-SCSI
VLS 300 EVA GatewayFibre ChannelHewlett Packard EnterpriseUltrium 230 LTO1HP^^^^^^VLS
HP^^^^^^Ultrium^1-SCSI
VLS 300 EVA GatewayFibre ChannelHewlett Packard EnterpriseUltrium 460 LTO2HP^^^^^^VLS
HP^^^^^^Ultrium^2-SCSI
VLS 300 EVA GatewayFibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3HP^^^^^^VLS
HP^^^^^^Ultrium^3-SCSI
VLS 6000 SeriesFibre ChannelHewlett Packard EnterpriseUltrium 230 LTO1HP^^^^^^VLS
HP^^^^^^Ultrium^1-SCSI
VLS 6000 SeriesFibre ChannelHewlett Packard EnterpriseUltrium 460 LTO2HP^^^^^^VLS
HP^^^^^^Ultrium^2-SCSI
VLS 6000 SeriesFibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3HP^^^^^^VLS
HP^^^^^^Ultrium^3-SCSI
VLS 9000 SeriesFibre ChannelHewlett Packard EnterpriseUltrium 230 LTO1HP^^^^^^VLS
HP^^^^^^Ultrium^1-SCSI
VLS 9000 SeriesFibre ChannelHewlett Packard EnterpriseUltrium 460 LTO2HP^^^^^^VLS
HP^^^^^^Ultrium^2-SCSI
VLS 9000 SeriesFibre ChannelHewlett Packard EnterpriseUltrium 960 LTO3HP^^^^^^VLS
HP^^^^^^Ultrium^3-SCSI
VLS 9200 SeriesFibre ChannelHewlett Packard EnterpriseUltrium 1840 LTO4HP^^^^^^VLS
HP^^^^^^Ultrium^4-SCSI